2015 – 2016 Demand Control Kitchen Ventilation
The U.S. Environmental Protection Agency (EPA) is pleased to recognize Demand Control Kitchen Ventilation (DCKV) with the ENERGY STAR® Emerging Technology Award for 2015 – 2016. DCKV technologies employ advanced sensors and variable speed controls to offer end users significant reductions in energy use and CO2 emissions compared to standard kitchen ventilation systems. Field studies suggest that energy savings could be 60% or more depending on the facility and type of operation.
Systems that meet the performance criteria for DCKV will be listed on this webpage once it is determined that all Award criteria have been satisfied.
2015-2016 Emerging Technology Award-Winning Demand Control Kitchen Ventilation Systems
- List of 2015-2016 Emerging Technology Award Systems (PDF, 194.48 KB)
Technology Overview
Commercial kitchen ventilation removed the heat and effluent generated by the cooking process from the kitchen space, ensuring the comfort and safety of the cooking staff and preventing cooking odors from spreading beyond the kitchen. Commercial kitchen ventilation is composed of an average of two hoods suspended above the cooking appliances, and ducting and fans necessary to expel the heat and effluent outside. To replace the air lost through this process, make-up air (MUA) must be provided by the building’s heating ventilation and HVAC system or a MUA system dedicated to the kitchen, which is composed of its own fans, ducts, and potentially heating or cooling depending on the climate.
DCKV provides control over the ventilation system by modulating the speed depending on cooking activity. Traditionally, commercial kitchen ventilation systems would operate at their maximum designed speed/volume throughout the duration of the kitchen’s operating hours or provide manual control over two speeds. In contrast, DCKV provides automatic, continuous control over fan speed in response to temperature, optical, or infrared (IR) sensors that monitor cooking activity or direct communication with cooking appliances.
Diagram of a DCKV system with infrared sensors that remotely monitor
the cooking surfaces
Source: Halton, "13 Coins Case Study: Airflow and Energy Savings with the Halton MARVEL System," Halton, 2013.
Typical power demand and savings from one exhaust fan due to a
DCKV retrofit in a hotel kitchen
Source: Southern California Edison, "Demand Control Ventilation for Commercial Kitchen Hoods," 2009
To learn more about these technologies and the savings potential, read EPA's DCKV Technology Profile (PDF, 313KB).