ENERGY STAR Ventilating Fans with Lighting Template

Service Method: Submit_Ventilating_Fans_with_Lighting_4_x
Version Number: V4 with Lighting
Description Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Residential Ventilating Fans Version 4.0, 4.1 and 4.2. This template is for ventilating fans with lighting. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History :
  • 08/01/2023 - Submit_Ventilating_Fans_with_Lighting_4_x Updated
  • 05/12/2021 - Submit_Ventilating_Fans_with_Lighting_4_x Updated
  • 07/26/2018 - Submit_Ventilating_Fans_with_Lighting_4_x Updated
  • 07/09/2015 - Submit_Ventilating_Fans_with_Lighting_4_x Final
  • 06/25/2015 - Submit_Ventilating_Fans_with_Lighting_4_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumeration Text
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80


ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer

Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200


Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration

Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)

Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date

ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Min Occurs: 0
Max Length: 400


Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Universal Product Code (UPC) Include UPC code(s) associated with the certified model, focusing on UPC codes featured in online listings. Do not include UPC codes if they are also associated with models not certified as ENERGY STAR. This field is available for all and required for select product categories unless not available. The UPC must be submitted as a string of digits when provided and should represent an actual UPC code. If not provided, the UPC code should be left blank and the reason for not including the UPC code will need to be submitted for the product to pass backend validation in EPA’s QPX system. O Y Text Min Occurs: 0
Max Occurs: unbounded
Min Length: 6
Max Length: 16


Reason for Not Providing UPC Code Required for select product categories if UPC code is not provided. O N Enumeration Data Min Occurs: 0

  • UPC Code Not Yet Assigned - CB Will Provide Later
  • UPC Code Not Yet Assigned - Partner Will Provide Later
  • No UPC Code Provided - Custom or Commercial Product
  • UPC Code Is Also Associated with Models Not Certified as ENERGY STAR
  • No UPC Code Provided - Other Reason

Other Reason for Not Providing UPC Code Required if Reason for Not Providing UPC Code equals "No UPC code provided – Other Reason" . O N Text Min Occurs: 0
Max Length: 2000


Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200


Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs and retail numbers. UPC codes should not be included in this field. Provide each Additional Identifying Information as a separate data entry along with the corresponding model name and model number. O N Text Min Occurs: 0
Max Length: 255


Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No

If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Min Occurs: 0
Max Length: 80


Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No

Date Available on Market Date model is first sold within one or more markets. R N Date

Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date

Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date

Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200


Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer Min Occurs: 0


  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Min Occurs: 0
Max Length: 200


In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States

Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Min Occurs: 0
Max Length: 2000


Product Specific Information  
ENERGY STAR Specification Version
R N Enumeration Data
  • 4.0
  • 4.1
  • 4.2

Product Type
R N Enumeration Data
  • Bathroom/Utility Room with Lighting
  • Range Hood with Lighting
  • In-line (multi-port) with Lighting
  • In-line (single-port) with Lighting

Number of Speeds Provide the number of speeds. For models with a rotary speed dial or similar mechanism that allows for a theoretically infinite number of speeds, indicate 3 for Number of Speeds. R N Integer Min Value: 1
Max Value: 3


Duct Size Diameter or Depth (in.) Provide the depth for rectangular ducts or the diameter for circular ducts. R N Decimal No. of Decimal: 2


Duct Size Width (in.) Required for model numbers with rectangular ducts. Provide the duct width. O N Decimal Min Occurs: 0
No. of Decimal: 2


Rated Input Power 1 (W) Required for Range Hoods. Provide the rated input power at the configuration selected in the field As Tested Configuration 1. O N Decimal Min Occurs: 0
No. of Decimal: 1
Max Value: 75


Measured Motor Wattage 1 (W) Provide the actual Motor Wattage at maximum (1) speed based on test data. For Range Hoods, provide the data at the configuration selected in the field As Tested Configuration 1. R N Decimal No. of Decimal: 1
Min Value: 0.1


Measured Airflow 1 (CFM) Provide the actual Airflow at maximum (1) speed based on test data, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the data at the configuration selected in the field As Tested Configuration 1. R N Decimal No. of Decimal: 1
Min Value: 0.1


Reported Airflow 1 (CFM) Provide the rated/reported Airflow at maximum (1) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the data at the configuration selected in the field As Tested Configuration 1. R N Decimal No. of Decimal: 1
Min Value: 0.1


Efficacy 1 (CFM/W) Provide the calculated efficacy at maximum (1) speed based on measured test data. For Range Hoods, provide the data at the configuration selected in the field As Tested Configuration 1. R N Decimal No. of Decimal: 1
Min Value: 2.8


Reported Sound Level 1 (sone) Required if Product Type is Range Hood or Bathroom or Utility Room. Provide the rated/reported Sound Level at maximum (1) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the data at the configuration selected in the field As Tested Configuration 1. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0
Max Value: 3.0


As-Tested Configuration 1 Required if Product Type is Range Hood. For Range Hoods, with single or more configurations, provide the as-tested configuration of the tested unit. O N Enumeration Data Min Occurs: 0

  • Horizontal
  • Vertical
  • Other

Rated Input Power 2 (W) Required if Range Hood with two or more configurations. Provide the rated input power at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Max Value: 75


Measured Motor Wattage 2 (W) Required if Bathroom, Utility or In-Line fans have two or more speeds or Range Hoods have two or more configurations. For Bathroom, Utility and In-Line fans, provide the actual Motor Wattage at next highest tested (2) speed based on test data. For Range Hoods, provide the actual Motor Wattage based on test data at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Measured Airflow 2 (CFM) Required if Bathroom, Utility or In-Line fans have two or more speeds or if Range Hoods have two or more configurations. For Bathroom, Utility and In-Line fans, provide the actual Airflow at next highest tested (2) speed based on test data, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the actual Airflow based on test data at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Reported Airflow 2 (CFM) Required if Bathroom, Utility or In-Line fans have two or more speeds or if Range Hoods have two or more configurations. For Bathroom, Utility and In-Line fans, provide the rated/reported Airflow at next highest tested (2) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the rated/reported Airflow at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Efficacy 2 (CFM/W) Required if Bathroom, Utility or In-Line fans have two or more speeds or if Range Hoods have two or more configurations. For Bathroom, Utility and In-Line fans, provide the calculated efficacy value at next highest tested (2) speed based on measured test data. For Range Hoods, provide the efficacy value based on measured test data at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 2.8


Reported Sound Level 2 (sone) Required if Bathroom, Utility or In-Line fans have two or more speeds or if Range Hoods have two or more configurations. For Bathroom, Utility and In-Line fans, provide the rated/reported Sound Level at next highest tested (2) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the rated/reported Sound Level at the configuration selected in the field As Tested Configuration 2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.0
Max Value: 3.0


As-Tested Configuration 2 Required if Product Type is Range Hood and unit has two or more configurations. Provide the second as-tested configuration of the tested unit. O N Enumeration Data Min Occurs: 0

  • Horizontal
  • Vertical
  • Other

Rated Input Power 3 (W) Required if Range Hood with three configurations. Provide the rated input power at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Max Value: 75


Measured Motor Wattage 3 (W) Required if Bathroom, Utility or In-Line fans have three or more speeds or if Range Hoods have three configurations. For Bathroom, Utility and In-Line fans, provide the actual Motor Wattage at minimum (3) speed based on test data. For Range Hoods, provide the actual Motor Wattage based on test data at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Measured Airflow 3 (CFM) Required if Bathroom, Utility or In-Line fans have three or more speeds or if Range Hoods have three configurations. For Bathroom, Utility and In-Line fans, provide the actual Airflow at minimum (3) speed based on test data, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the actual Airflow based on test data at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Reported Airflow 3 (CFM) Required if Bathroom, Utility or In-Line fans have three or more speeds or if Range Hoods have three configurations. For Bathroom, Utility and In-Line fans, provide the rated/reported Airflow at minimum (3) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the rated/reported Airflow at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Efficacy 3 (CFM/W) Required if Bathroom, Utility or In-Line fans have three or more speeds or if Range Hoods have three configurations. For Bathroom, Utility and In-Line fans, provide the calculated efficacy value at the minimum (3) speed based on measured test data. For Range Hoods, provide the calculated efficacy value based on measured test data at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 2.8


Reported Sound Level 3 (sone) Required if Bathroom, Utility or In-Line fans have three or more speeds or if Range Hoods have three configurations. For Bathroom, Utility and In-Line fans, provide the rated/reported Sound Level minimum (3) speed, which will appear on the ENERGY STAR list of certified products. For Range Hoods, provide the rated/reported Sound Level at the configuration selected in the field As Tested Configuration 3. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0


As-Tested Configuration 3 Required if Product Type is Range Hood. For Range Hoods with three configurations, provide the third as-tested configuration of the tested unit. O N Enumeration Data Min Occurs: 0

  • Horizontal
  • Vertical
  • Other

Other Configuration Explanation Required if Product Type is Range Hood and Unit As-Tested Configuration is Other for one or more as-tested configurations. Provide an explanation of as-tested configuration. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Measured Airflow at 0.25 in. w.g. (CFM) at Maximum Speed Required if Product Type is Bathroom or Utility Room. Provide the actual airflow based on .25 inch water gauge (w.g.) static pressure test data. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 0.1


Percentage of Airflow at 0.1 w.g. at Maximum Speed Required if Product Type is Bathroom or Utility Room. Provide the actual airflow percentage equal to or greater than .1 inch water gauge (w.g.) static pressure test data, expressed as a percentage. O N Integer Min Occurs: 0
Min Value: 70


Optional Sound Level (sone) at 0.25 in w.g. at Maximum Speed If Product Type is Bathroom or Utility Room it is optional to provide the actual sound level based on 0.25 inch w.g. static pressure test data. O N Decimal Min Occurs: 0
No. of Decimal: 1


Ventilating Fan Features Select all that apply to the operation of the ventilating fan. O Y Enumeration Data Min Occurs: 0
Max Occurs: 4

  • Motion sensor
  • Humidity sensor
  • Timer
  • Connected functionality

Additional Features Provide additional features not associated with fan or lighting performance, such as speakers, etc. O N Text Min Occurs: 0
Max Length: 1000


Lighting Program Type This field is no longer relevant for V4.2. O N Enumeration Data Min Occurs: 0

  • Luminaires
  • Lamps

ENERGY STAR Lamp ESUID This field is no longer relevant for V4.2. O N Integer Min Occurs: 0


Alternate ENERGY STAR Lamp ESUIDs This field is no longer relevant for V4.2. O Y Integer Min Occurs: 0
Max Occurs: unbounded


Lighting Technology Required for vent fans with lighting to include lighting technology in the certified product listing. O N Enumeration Data Min Occurs: 0

  • LED
  • Fluorescent
  • HID

Source Type This field is no longer relevant for V4.2. O N Enumeration Data Min Occurs: 0

  • Self-ballasted CFL (GU24)
  • Compact Fluorescent
  • Linear Fluorescent
  • Circline
  • High Pressure Sodium
  • Metal Halide
  • Ceramic Metal Halide
  • GU24 Based Integrated LED Lamp
  • LED Light Engine
  • Inseparable LED Source (modules, arrays, packages)

Light Source is Self-ballasted or has Integrated Driver This field is no longer relevant for V4.2. O N Enumeration Data Min Occurs: 0

  • Yes
  • No
  • N/A

Light Source Shipped with Vent Fan? This field is no longer relevant for V4.2. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

External Ballast/Driver Manufacturer This field is no longer relevant for V4.2. O N Text Min Occurs: 0
Max Length: 1000


External Ballast/Driver Model Number This field is no longer relevant for V4.2. O N Text Min Occurs: 0
Max Length: 1000


Number of Light Sources per Ballast/Driver This field is no longer relevant for V4.2. O N Integer Min Occurs: 0


Number of Ballasts/Drivers per Vent Fan This field is no longer relevant for V4.2. O N Integer Min Occurs: 0


Reported Input Power of Light Source (W) Required for vent fans with lighting to include input power in the certified product listing. Reported input power of the light source should be consistent with the value stated on the product packaging. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0.00
Max Value: 250.00


Efficacy (lm/W) This field is no longer relevant for V4.2. O N Decimal Min Occurs: 0
No. of Decimal: 1
Min Value: 42


Reported Light Output (lm) Required for vent fans with lighting to include reported light output in the certified product listing. Reported light output should be consistent with the value stated on product packaging. O N Integer Min Occurs: 0


Light Source Life (hours) Required for vent fans with lighting to include light source life in the certified product listing. O N Integer Min Occurs: 0
Min Value: 6000


Color Rendering Index (CRI) Required for vent fans with lighting to include CRI in the certified product listing. O N Integer Min Occurs: 0
Min Value: 80
Max Value: 100


Nominal Correlated Color Temperature (CCT) Required for vent fans with lighting to include CCT in the certified product listing. O N Enumeration Data Min Occurs: 0

  • 2700K
  • 3000K
  • 3500K
  • 4000/4100K
  • 5000K

Mercury Content (mg) This field is no longer relevant for V4.2. O N Decimal Min Occurs: 0
No. of Decimal: 1


Dimmable Required for vent fans with lighting to include dimming capability in the certified product listing. O N Enumeration Data Min Occurs: 0

  • Non-Dimmable
  • Continuous Dimming
  • Step Dimming

Luminaire Features Required for vent fans to include special lighting features in the certified product listing. O Y Enumeration Data Min Occurs: 0
Max Occurs: 10

  • Connected Functionality
  • Color Tunable
  • White Light Tunable
  • Motion Sensor
  • Damp Location Rated
  • Wet Location Rated
  • Warm Dimming
  • DALI Dimming
  • 0-10V Dimming
  • Wireless Dimming

Power Factor This field is no longer relevant for V4.2. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00


Additional Allowable Light Source Manufacturer This field is no longer relevant for V4.2. O N Text Min Occurs: 0
Max Length: 1000


Additional Allowable Light Source Model Number This field is no longer relevant for V4.2. O N Text Min Occurs: 0
Max Length: 1000


Displayed Notes This field is no longer relevant for V4.2. O N Text Min Occurs: 0
Max Length: 1000