Description Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Residential Electric Cooking Products Version 1.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History :
  • 10/11/2023 - Submit_Residential_Electric_Cooking_Products_1_x Final
  • 10/06/2023 - Submit_Residential_Electric_Cooking_Products_1_x Updated
  • 09/26/2023 - Submit_Residential_Electric_Cooking_Products_1_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumeration Text
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80


ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer

Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200


Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration

Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)

Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date

ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Min Occurs: 0
Max Length: 400


Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Universal Product Code (UPC) Include UPC code(s) associated with the certified model, focusing on UPC codes featured in online listings. Do not include UPC codes if they are also associated with models not certified as ENERGY STAR. This field is available for all and required for select product categories unless not available. The UPC must be submitted as a string of digits when provided and should represent an actual UPC code. If not provided, the UPC code should be left blank and the reason for not including the UPC code will need to be submitted for the product to pass backend validation in EPA’s QPX system. O Y Text Min Occurs: 0
Max Occurs: unbounded
Min Length: 6
Max Length: 16


Reason for Not Providing UPC Code Required for select product categories if UPC code is not provided. O N Enumeration Data Min Occurs: 0

  • UPC Code Not Yet Assigned - CB Will Provide Later
  • UPC Code Not Yet Assigned - Partner Will Provide Later
  • No UPC Code Provided - Custom or Commercial Product
  • UPC Code Is Also Associated with Models Not Certified as ENERGY STAR
  • No UPC Code Provided - Other Reason

Other Reason for Not Providing UPC Code Required if Reason for Not Providing UPC Code equals "No UPC code provided – Other Reason" . O N Text Min Occurs: 0
Max Length: 2000


Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200


Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs and retail numbers. UPC codes should not be included in this field. Provide each Additional Identifying Information as a separate data entry along with the corresponding model name and model number. O N Text Min Occurs: 0
Max Length: 255


Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No

If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Min Occurs: 0
Max Length: 80


Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No

Date Available on Market Date model is first sold within one or more markets. R N Date

Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date

Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date

Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200


Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer Min Occurs: 0


  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Min Occurs: 0
Max Length: 200


In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States

Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Min Occurs: 0
Max Length: 2000


Product Specific Information  
ENERGY STAR Specification Version
R N Enumeration Data
  • 1.0

Product Type Designate the technology type of the electric cooking top. R N Enumeration Data
  • Cooktop
  • Range

Installation Type Specify the installation type of the cooking top. R N Enumeration Data
  • Portable
  • Built-in/Slide-in
  • Freestanding

Cooktop Technology Provide heating technology used in cooking product. R Y Enumeration Data Min Occurs: 1
Max Occurs: 4

  • Induction
  • Radiant
  • Coil
  • Other

Cooktop Technology - Other Required if Cooktop Technology is Other. Indicate cooktop technology. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Height (inches) Provide the product height (inches) excluding handles, knobs and Coils. R N Decimal No. of Decimal: 2


Depth (inches) Provide the product depth (inches) excluding handles or knobs. R N Decimal No. of Decimal: 2


Width (inches) Provide the product width (inches) excluding handles or knobs. R N Decimal No. of Decimal: 2


Number of Cooking Zones Provide the total number of cooking zones available on the cooking tops. R N Integer Min Value: 1


Control Type Indicate the control interface type used on the cooking product. R Y Enumeration Data Min Occurs: 1
Max Occurs: 4

  • Digital
  • Knobs
  • Touch Control
  • Other

Control Type - Other Required if Control Type is Other. Indicate relevant interface type. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Rated Nameplate Voltage (V) Provide the manufacturer reported value. R N Enumeration Data
  • 120 V
  • 220 V
  • 240 V

Rated Nameplate Amperage (Amps) Provide the manufacturer reported minimum circuit amperage value. R N Enumeration Data
  • 5
  • 10
  • 15
  • 20
  • 30
  • 40
  • 50
  • 60
  • Other

Rated Nameplate Amperage (Amps) - Other Required if rated nameplate amperage is other. Provide the manufacturer reported minimum circuit amperage value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Specialty Zones Provide any specialty zones if included in the product. For concentric cooking zones are heating zones that have two or three concentric circles that have the same center point, the circle used is to correspond to the cookware size. Indicate if the cooking top has dual, triple, or no concentric cooking zones. For bridge element, report if two or more cooking zones can be merged and synced to create a larger cooking area or specialty zone acting in unison. O Y Enumeration Data Min Occurs: 0
Max Occurs: 9

  • Simmer Zone
  • Warming Zone
  • Melting Zone
  • Griddle Zone
  • Power Heating Zone
  • Dual Concentric Cooking Zones
  • Triple Concentric Cooking Zones
  • Bridge Element
  • Other

Specialty Zones - Other Required if specialty zones are other. Indicate the Specialty Zones. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Smart Capabilities Indicate if the product has smart capabilities allowing it to connect to other devices or networks via different wireless protocols. O Y Enumeration Data Min Occurs: 0
Max Occurs: 8

  • Wifi Enabled
  • Status Notifications
  • Energy Usage Reporting
  • Remote Oven Control
  • Cooking Progress Monitoring
  • Sync Capability with Vent Fan
  • Sync Capability with Cookware
  • Other

Smart Capabilities - Other Required if Smart Capabilities is Other. Indicate relevant smart capabilities type. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Additional Product Features Indicate the features that are applicable to the cooking top. Please indicate none if your product does not include additional features. R Y Enumeration Data Min Occurs: 1
Max Occurs: 7

  • Cookware presence sensor
  • Cookware size sensor
  • Indicator Light - Hot Surface
  • Indicator Light - Heating Element On
  • Controls Lock
  • Active Cooling
  • Other
  • None

Additional Product Features - Other Required if Additional Product Features is Other. Indicate relevant feature(s). O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Calculated Integrated Annual Energy Consumption (kWh/year) Provide the calculated value based on measured test data. R N Decimal No. of Decimal: 2
Min Value: 0
Max Value: 195


Reported Integrated Annual Energy Consumption (kWh/year) Provide the rated/reported Annual Energy Consumption, which will appear on the ENERGY STAR list of certified products. R N Integer Min Value: 0
Max Value: 195


Low-Power Mode Energy Consumption for Oven Component (kWh/year) Provide the measured annual combined low-power mode energy consumption of the conventional electric oven component of a combined electric cooking product, ETLP,O (kWh/year) based on measured test data. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0
Max Value: 7


Low-Power Mode Energy Consumption for Cooking Top (kWh/year) Provide the measured annual combined low-power mode energy consumption for the cooking top, ETLP (kWh/year) based on measured test data. R N Decimal No. of Decimal: 2
Min Value: 0
Max Value: 195


Average Cooking Zone Time (seconds) Provide the average heat up time to 90C (t90) for all cooking zones. R N Integer Min Value: 1


Cooking Zone #1 Time t90 (seconds) Required if the simmer test is measured. Provide the heat up time to 90C (t90) for the first cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #2 Time t90 (seconds) Required if the simmer test is measured and the product has at least two cooking zones. Provide the heat up time to 90C (t90) for the second cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #3 Time t90 (seconds) Required if the simmer test is measured and the product has at least three cooking zones. Provide the heat up time to 90C (t90) for the third cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #4 Time t90 (seconds) Required if the simmer test is measured and the product has at least four cooking zones. Provide the heat up time to 90C (t90) for the fourth cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #5 Time t90 (seconds) Required if the simmer test is measured and the product has at least five cooking zones. Provide the heat up time to 90C (t90) for the fifth cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #6 Time t90 (seconds) Required if the simmer test is measured and the product has at least six cooking zones. Provide the heat up time to 90C (t90) for the sixth cooking zone. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #1 Maximum Size (mm) Provide the maximum size of the first cooking zone. R N Integer Min Value: 1


Cooking Zone #2 Maximum Size (mm) Provide the maximum size of the second cooking zone. Required if the product has at least two cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #3 Maximum Size (mm) Provide the maximum size of the third cooking zone. Required if the product has at least three cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #4 Maximum Size (mm) Provide the maximum size of the fourth cooking zone. Required if the product has at least four cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #5 Maximum Size (mm) Provide the maximum size of the fifth cooking zone. Required if the product has at least five cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #6 Maximum Size (mm) Provide the maximum size of the sixth cooking zone. Required if the product has at least six cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #1 Wattage (W) Provide the rated wattage of the first cooking zone. R N Integer Min Value: 1


Cooking Zone #2 Wattage (W) Provide the rated wattage of the second cooking zone. Required if the product has at least two cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #3 Wattage (W) Provide the rated wattage of the third cooking zone. Required if the product has at least three cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #4 Wattage (W) Provide the rated wattage of the fourth cooking zone. Required if the product has at least four cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #5 Wattage (W) Provide the rated wattage of the fifth cooking zone. Required if the product has at least five cooking zones. O N Integer Min Occurs: 0
Min Value: 1


Cooking Zone #6 Wattage (W) Provide the rated wattage of the sixth cooking zone. Required if the product has at least six cooking zones. O N Integer Min Occurs: 0
Min Value: 1