ENERGY STAR Enterprise Servers Template

Service Method: Submit_Enterprise_Servers_4_x
Version Number: V4
Description Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Enterprise Servers Version 4.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History :
  • 04/28/2023 - Submit_Enterprise_Servers_4_x Final
  • 04/13/2023 - Submit_Enterprise_Servers_4_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumeration Text
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80


ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer

Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200


Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration

Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)

Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date

ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400


Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Min Occurs: 0
Max Length: 400


Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255


Universal Product Code (UPC) Include UPC code(s) associated with the certified model, focusing on UPC codes featured in online listings. Do not include UPC codes if they are also associated with models not certified as ENERGY STAR. This field is available for all and required for select product categories unless not available. The UPC must be submitted as a string of digits when provided and should represent an actual UPC code. If not provided, the UPC code should be left blank and the reason for not including the UPC code will need to be submitted for the product to pass backend validation in EPA’s QPX system. O Y Text Min Occurs: 0
Max Occurs: unbounded
Min Length: 6
Max Length: 16


Reason for Not Providing UPC Code Required for select product categories if UPC code is not provided. O N Enumeration Data Min Occurs: 0

  • UPC Code Not Yet Assigned - CB Will Provide Later
  • UPC Code Not Yet Assigned - Partner Will Provide Later
  • No UPC Code Provided - Custom or Commercial Product
  • UPC Code Is Also Associated with Models Not Certified as ENERGY STAR
  • No UPC Code Provided - Other Reason

Other Reason for Not Providing UPC Code Required if Reason for Not Providing UPC Code equals "No UPC code provided – Other Reason" . O N Text Min Occurs: 0
Max Length: 2000


Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200


Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255


Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Min Occurs: 0
Max Length: 255


  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs and retail numbers. UPC codes should not be included in this field. Provide each Additional Identifying Information as a separate data entry along with the corresponding model name and model number. O N Text Min Occurs: 0
Max Length: 255


Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No

If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Min Occurs: 0
Max Length: 80


Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No

Date Available on Market Date model is first sold within one or more markets. R N Date

Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date

Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date

Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200


Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. R Y
Min Occurs: 0
Max Occurs: unbounded


  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer Min Occurs: 0


  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Min Occurs: 0
Max Length: 200


In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States

Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Min Occurs: 0
Max Length: 2000


Product Specific Information  
ENERGY STAR Specification Version
R N Enumeration Data
  • 4.0

Product Form Factor
R N Enumeration Data
  • Tower/Pedestal
  • Rack-mount
  • Multi-node
  • Blade - Half Chassis
  • Blade - Full Chassis
  • Other

Product Processor Socket Count Number of processor sockets available on the motherboard of the product. R N Enumeration Data
  • 1
  • 2
  • 4
  • Greater than 4

Single Server Indicate Yes if certification is for a single server. If certification is for a product family submission, indicate No. R N Enumeration Data
  • Yes
  • No

Storage Heavy Server
R N Enumeration Data
  • Yes
  • No

Resilient System
R N Enumeration Data
  • Yes
  • No

Number of Nodes for Multi-node Required if Product Type is Multi-node. O N Integer Min Occurs: 0
Min Value: 0


Error Correcting Code Indicate Yes if all memory options in the system offer Error Correcting Code. R N Enumeration Data
  • Yes
  • No

Error Correcting Code Enabled in Hardware as Shipped
R N Enumeration Data
  • Yes
  • No

Available Expansion Slots Indicate the number of available expansion slots for I/O Devices and APAs. R N Integer Min Value: 0


Operating Systems Supported
R Y Enumeration Data Min Occurs: 1
Max Occurs: 6

  • Windows
  • Linux
  • Unix
  • Solaris
  • SPARC
  • Other

Operating Systems Used for Testing
R N Enumeration Data
  • Windows
  • Linux
  • Unix
  • Solaris
  • SPARC
  • Other

SERT Submission System URL for Model Indicate the name of the URL for SERT files location provided by the SERT data submission system. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Saving Features Available
R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Dynamic voltage and frequency scaling of processor(s)
  • Processor or core reduced power states
  • Power capping
  • Variable speed fan control based on power or thermal readings
  • Low power memory states
  • Low power I/O states
  • Other
  • None

Power Saving Features Enabled Identify Power Saving Features enabled by default upon shipment. R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Dynamic voltage and frequency scaling of processor(s)
  • Processor or core reduced power states
  • Power capping
  • Variable speed fan control based on power or thermal readings
  • Low power memory states
  • Low power I/O states
  • Other
  • None

End User Required Power Saving Features Identify Power Saving Features that require the end user to enable them. R Y Enumeration Data Min Occurs: 1
Max Occurs: 8

  • Dynamic voltage and frequency scaling of processor(s)
  • Processor or core reduced power states
  • Power capping
  • Variable speed fan control based on power or thermal readings
  • Low power memory states
  • Low power I/O states
  • Other
  • N/A

Other Power Saving Feature 1: Description Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Provide power saving feature. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Other Power Saving Feature 1: Enabled on Shipment Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 1: End-User Enabling Required Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 2: Description Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Provide power saving feature. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Other Power Saving Feature 2: Enabled on Shipment Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 2: End-User Enabling Required Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 3: Description Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Provide power saving feature. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Other Power Saving Feature 3: Enabled on Shipment Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 3: End-User Enabling Required Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 4: Description Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Provide power saving feature. If more than four Power Saving Features, separate features using a semi-colon. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Other Power Saving Feature 4: Enabled on Shipment Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Other Power Saving Feature 4: End-User Enabling Required Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

APA #1 Model Name Required if APA #1 is included in configuration. Indicate model name of the available APA with the highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #1 Model Number Required if APA #1 is included in configuration. Indicate model number of the available APA with the highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #1 Reported Idle Power (Watts) Required if APA #1 is included in configuration. Indicate manufacturer reported idle power value of the available APA with the highest idle power value. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0


APA #2 Model Name Required if APA #2 is included in configuration. Indicate model name of the available APA with the second highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #2 Model Number Required if APA #2 is included in configuration. Indicate model number of the available APA with the second highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #2 Reported Idle Power (Watts) Required if APA #2 is included in configuration. Indicate manufacturer reported idle power value of the available APA with the second highest idle power value. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0


APA #3 Model Name Required if APA #3 is included in configuration. Indicate model name of the available APA with the third highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #3 Model Number Required if APA #3 is included in configuration. Indicate model number of the available APA with the third highest idle power value. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


APA #3 Reported Idle Power (Watts) Required if APA #3 is included in configuration. Indicate manufacturer reported idle power value of the available APA with the third highest idle power value. O N Decimal Min Occurs: 0
No. of Decimal: 2
Min Value: 0


Additional APA Model Numbers Required if additional APAs are shipped with the computer server beyond the three listed above. Indicate each model number separated by semi-colons in this field. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Power Management Enabled in Hardware on Shipment
R N Enumeration Data
  • Yes
  • No

Processor Power Management Additional Information Required if additional processor power management information is available. Provide any additional information on the processor power management that is enabled on shipment including what power management options are deployed. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Storage Power Management Enabled in Hardware on Shipment
R N Enumeration Data
  • Yes
  • No

Storage Power Management Additional Information Required if additional storage power management information is available. Provide any additional information on the storage power management that is enabled on shipment including what power management options are deployed. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Memory Power Management Enabled in Hardware on Shipment
R N Enumeration Data
  • Yes
  • No

Memory Power Management Additional Information Required if additional memory power management information is available. Provide any additional information on the memory power management that is enabled on shipment including what power management options are deployed. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


I/O Power Management Enabled in Hardware on Shipment Indicate if I/O (Input/Output) devices contain power management enabled in hardware on shipment. R N Enumeration Data
  • Yes
  • No

I/O Power Management Additional Information Required if additional I/O power management information is available. Provide any additional information on the I/O devices power management that is enabled on shipment including what power management options are deployed. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Dynamic Voltage Scaling Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Processor Dynamic Frequency Scaling Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Processor Dynamic Voltage Scaling End-User Enabling Required
R N Enumeration Data
  • Yes
  • No

Processor Dynamic Frequency Scaling End-User Enabling Required
R N Enumeration Data
  • Yes
  • No

Processor or Core Reduced Power States Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Processor or Core Reduced Power States Enabling Required Indicate Yes if the end-user is required to enable processor or core reduced power states. R N Enumeration Data
  • Yes
  • No

Power Capping Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Power Capping End-User Enabling Required
R N Enumeration Data
  • Yes
  • No

Variable Speed Fan Control Enabled on Shipment Indicate Yes if the variable speed fan control based on power or thermal readings is enabled on shipment. R N Enumeration Data
  • Yes
  • No

Variable Speed Fan Control End-User Enabling Required Indicate Yes if the variable speed fan control based on power or thermal readings is required to be enabled by the end-user. R N Enumeration Data
  • Yes
  • No

Low Power Memory States Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Low Power Memory States End-User Enabling Required
R N Enumeration Data
  • Yes
  • No

Low Power I/O States Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Liquid Cooling Capability Enabled on Shipment
R N Enumeration Data
  • Yes
  • No

Liquid Cooling Capability End-User Enabling Required
R N Enumeration Data
  • Yes
  • No

Available DIMM Slots For blade or multi-node systems, indicate the number of available DIMM slots per blade or node. R N Integer Min Value: 0


Number of System Memory Channels For blade or multi-node systems, indicate the number of system memory channels per blade or node. R N Integer Min Value: 0


Maximum Memory Capacity
R N Decimal No. of Decimal: 2


Maximum Number Blade Slots Required if Product Type is Blade Server. Indicate the maximum number of blade slots for this configuration. O N Integer Min Occurs: 0
Min Value: 0


Other Chassis Features Required if additional chassis features are available. Indicate additional chassis features such as common storage, networking, etc. for this configuration. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


SERT Version Required for models certified using SERT 2.0.1. Indicate the SERT version used for certification. R N Enumeration Data
  • 2.0.1
  • Other

SERT Version Other Required if SERT version used for certification is not Version 2.0.1, indicate SERT version used during testing. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


64-bit Architecture Indicate Yes if 64-bit architecture is supported. Indicate No if only 32-bit architecture is supported. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

SERT Test Results Folder Name Indicate the name of the folder that the CB has created in the EPA SERT data upload website which contains all of the required SERT files defined in Section 4.1.2.v of the Version 3.0 specification. R N Text Min Length: 1
Max Length: 1000


Model Number or Config ID for Low-end Performance Configuration Required if Product Family is Yes. See ENERGY STAR Computer Servers V3.0.1, Section G.2, for definition of Low-end Performance Configuration. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Installed Processors for Low-end Performance Configuration Required if Product Family is Yes. If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. O N Integer Min Occurs: 0
Min Value: 1
Max Value: 4


Cores Per Processor Low-end Performance Configuration Required if Product Family is Yes. O N Integer Min Occurs: 0
Min Value: 1


Number of System Threads for Low-end Performance Configuration Required if Product Family is Yes. For blade or multi-node systems, indicate the number of system threads per blade or node. O N Integer Min Occurs: 0
Min Value: 0


Processor Brand Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Model Name Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Speed for Low-end Performance Configuration (GHz) Required if Product Family is Yes. O N Decimal Min Occurs: 0
No. of Decimal: 3
Min Value: 0


Num. of Buffered DDR Channels for Low-end Perform.Config. Required if Product Family is Yes. Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. O N Integer Min Occurs: 0
Min Value: 0


Memory Manufacturer for Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Memory Model Number Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Memory Speed Low-end Performance Configuration (GHz) Indicate the speed of the installed memory for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


Low-end Performance Configuration Size Per DIMM (GB) Required if Product Family is Yes. If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Installed Num. DIMMs for Low-end Performance Configuration Required if Product Family is Yes. For blade or multi-node systems, indicate the installed number of DIMMs per blade or node. O N Integer Min Occurs: 0
Min Value: 0


Installed Memory for Low-end Performance Configuration (GB) Required if Product Family is Yes. Indicate total installed memory for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


Num. Solid State Drives (SSDs) Low-end Performance Configuration Required if Product Family is Yes. Indicate how many SSDs are contained in this configuration. O N Integer Min Occurs: 0
Min Value: 0


Number Rotational Drives Low-end Performance Configuration Required if Product Family is Yes. Indicate how many rotational drives are contained in this configuration. O N Integer Min Occurs: 0
Min Value: 0


Low-end Performance Configuration Redundant Power Supply Required if Product Family is Yes. Indicate if the power supply unit (PSU) is redundant capable. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Power Supply Type for Low-end Performance Configuration Required if Product Family is Yes. O N Enumeration Data Min Occurs: 0

  • Single-Output
  • Multi-Output

Power Supply Manufacturer Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Model Name Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Model Number Low-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Rated Output Low-end Performance Configuration (W) Required if Product Family is Yes. O N Decimal Min Occurs: 0
No. of Decimal: 2


Num. Power Supplies for Low-end Performance Configuration Required if Product Family is Yes. Indicate the number of power supplies installed. O N Integer Min Occurs: 0
Min Value: 0


Number of PSU for Redundancy Low-end Performance Configuration Required if Product Family is Yes and the power supply unit (PSU) is redundant capable. O N Integer Min Occurs: 0
Min Value: 0


PSU 80Plus Platinum Certified Low-end Performance Configuration Required if Product Family is Yes. Indicate if the power supply unit meets the criteria for the 80Plus Platinum Certification. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

SERT Compress Eff. Score for Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT CryptoAES Efficiency Score Low-end Performance Config Required if Product Family is Yes. Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT LU Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU LU Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SORT Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU SORT Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SHA256 Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Flood Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Memory Flood Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Capacity Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Sequential Efficiency Score Low-end Performance Config Required if Product Family is Yes. Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Random Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Storage Random Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SSJ Efficiency Score Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Idle Measurement (Watts) Low-end Performance Configuration Required if Product Family is Yes. Indicate the SERT measured idle power in watts for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Active State Efficiency Score Low-end Performance Config Required if Product Family is Yes. Indicate the SERT Active State Efficiency Score as defined in ENERGY STAR Computer Servers V3, Equation 3. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Total Server Normalized Perform. Score Low-end Config Required if Product Family is Yes. Indicate manufacturer reported total normalized performance component (numerator) used to calculate the configuration’s Active State Efficiency Score. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Total Server Power Score (Watts) Low-end Performance Config Required if Product Family is Yes. Indicate manufacturer reported total power component (denominator) used to calculate the configuration’s Active State Efficiency Score. O N Decimal Min Occurs: 0
No. of Decimal: 2


Tested Num. Blade Slots Low-end Performance Configuration Required if Product Family is Yes and Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. O N Integer Min Occurs: 0
Min Value: 0


Model Number or Config ID for Typical or Single Configuration See ENERGY STAR Computer Servers V3.0, Section G.2, for definition of Typical or Single Configuration. O N Text Min Occurs: 0
Max Length: 1000


Installed Processors for Typical or Single Configuration If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. R N Integer Min Value: 1
Max Value: 4


Cores Per Processor Typical or Single Configuration
R N Integer Min Value: 1


Number of System Threads for Typical or Single Configuration Required if Product Family is Yes. For blade or multi-node systems, indicate the number of system threads per blade or node. R N Integer Min Value: 0


Processor Brand Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Processor Model Name Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Processor Speed for Typical or Single Configuration (GHz)
R N Decimal No. of Decimal: 3
Min Value: 0


Num. of Buffered DDR Channels for Typical or Single Config Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. R N Integer Min Value: 0


Memory Manufacturer for Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Memory Model Number Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Memory Speed Typical or Single Configuration (GHz) Indicate the speed of the installed memory for this configuration. R N Decimal No. of Decimal: 2


Typical or Single Configuration Size Per DIMM (GB) If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. R N Text Min Length: 1
Max Length: 1000


Installed Num. DIMMs for Typical or Single Configuration Required if Product Family is Yes. For blade or multi-node systems, indicate the installed number of DIMMs per blade or node. R N Integer Min Value: 0


Installed Memory for Typical or Single Configuration (GB) Indicate total installed memory for this configuration. R N Decimal No. of Decimal: 2


Num. Solid State Drives (SSDs) Typical or Single Configuration Indicate how many SSDs are contained in this configuration. R N Integer Min Value: 0


Number Rotational Drives Typical or Single Configuration Indicate how many rotational drives are contained in this configuration. R N Integer Min Value: 0


Typical or Single Configuration Redundant Power Supply Indicate if the power supply unit (PSU) is redundant capable. R N Enumeration Data
  • Yes
  • No

Power Supply Type for Typical or Single Configuration
R N Enumeration Data
  • Single-Output
  • Multi-Output

Power Supply Manufacturer Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Power Supply Model Name Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Power Supply Model Number Typical or Single Configuration
R N Text Min Length: 1
Max Length: 1000


Power Supply Rated Output Typical or Single Configuration (W)
R N Decimal No. of Decimal: 2


Num. Power Supplies for Typical or Single Configuration Indicate the number of power supplies installed. R N Integer Min Value: 0


Number of PSU for Redundancy Typical or Single Configuration Required if the power supply unit (PSU) is redundant capable. O N Integer Min Occurs: 0
Min Value: 0


PSU 80Plus Platinum Certified Typical or Single Configuration Indicate if the power supply unit meets the criteria for the 80Plus Platinum Certification. R N Enumeration Data
  • Yes
  • No

SERT Compress Eff. Score for Typical or Single Configuration Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT CryptoAES Efficiency Score Typical or Single Configuration Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT LU Efficiency Score Typical or Single Configuration Indicate the SERT CPU LU Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT SOR Efficiency Score Typical or Single Configuration Indicate the SERT CPU SOR Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT SORT Efficiency Score Typical or Single Configuration Indicate the SERT CPU SORT Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT SHA256 Efficiency Score Typical or Single Configuration Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT Flood Efficiency Score Typical or Single Configuration Indicate the SERT Memory Flood Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT Capacity Efficiency Score Typical or Single Configuration Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT Sequential Efficiency Score Typical or Single Configuration Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT Random Efficiency Score Typical or Single Configuration Indicate the SERT Storage Random Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT SSJ Efficiency Score Typical or Single Configuration Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. R N Decimal No. of Decimal: 2


SERT Idle Measurement (Watts) Typical or Single Configuration Indicate the SERT measured idle power in watts for this configuration. R N Decimal No. of Decimal: 2


SERT Active State Efficiency Score Typical or Single Config Indicate the SERT Active State Efficiency Score as defined in ENERGY STAR Computer Servers V3, Equation 3. R N Decimal No. of Decimal: 2


SERT Total Server Normal Perform. Score Typical or Single Config Indicate manufacturer reported total normalized performance component (numerator) used to calculate the configuration’s Active State Efficiency Score. R N Decimal No. of Decimal: 2


SERT Total Server Power Score (Watts) Typical or Single Config Indicate manufacturer reported total power component (denominator) used to calculate the configuration’s Active State Efficiency Score. R N Decimal No. of Decimal: 2


Tested Num. Blade Slots Typical or Single Configuration Required if Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. O N Integer Min Occurs: 0
Min Value: 0


Model Number or Config ID for High-end Performance Configuration Required if Product Family is Yes. See ENERGY STAR Computer Servers V3.0, Section G.2, for definition of High-end Performance Configuration. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Installed Processors for High-end Performance Configuration Required if Product Family is Yes. If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. O N Integer Min Occurs: 0
Min Value: 1
Max Value: 4


Cores Per Processor High-end Performance Configuration Required if Product Family is Yes. O N Integer Min Occurs: 0
Min Value: 1


Number of System Threads for High-end Performance Configuration Required if Product Family is Yes For blade or multi-node systems, indicate the number of system threads per blade or node. O N Integer Min Occurs: 0
Min Value: 0


Processor Brand High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Model Name High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Processor Speed for High-end Performance Configuration (GHz) Required if Product Family is Yes. O N Decimal Min Occurs: 0
No. of Decimal: 3
Min Value: 0


Num. of Buffered DDR Channels for High-end Performance Config Required if Product Family is Yes. Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. O N Integer Min Occurs: 0
Min Value: 0


Memory Manufacturer for High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Memory Model Number High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Memory Speed High-end Performance Configuration (GHz) Indicate the speed of the installed memory for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


High-end Performance Configuration Size Per DIMM (GB) Required if Product Family is Yes. If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Installed Num. DIMMs for High-end Performance Configuration Required if Product Family is Yes. For blade or multi-node systems, indicate the installed number of DIMMs per blade or node. O N Integer Min Occurs: 0
Min Value: 0


Installed Memory for High-end Performance Configuration (GB) Required if Product Family is Yes. Indicate total installed memory for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


Num. Solid State Drives (SSDs) High-end Performance Config Required if Product Family is Yes. Indicate how many SSDs are contained in this configuration. O N Integer Min Occurs: 0
Min Value: 0


Number Rotational Drives High-end Performance Configuration Required if Product Family is Yes. Indicate how many rotational drives are contained in this configuration. O N Integer Min Occurs: 0
Min Value: 0


High-end Performance Configuration Redundant Power Supply Required if Product Family is Yes. Indicate if the power supply unit (PSU) is redundant capable. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

Power Supply Type for High-end Performance Configuration
O N Enumeration Data Min Occurs: 0

  • Single-Output
  • Multi-Output

Power Supply Manufacturer High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Model Name High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Model Number High-end Performance Configuration Required if Product Family is Yes. O N Text Min Occurs: 0
Min Length: 0
Max Length: 1000


Power Supply Rated Output High-end Performance Configuration (W) Required if Product Family is Yes. O N Decimal Min Occurs: 0
No. of Decimal: 2


Num. Power Supplies for High-end Performance Configuration Required if Product Family is Yes. Indicate the number of power supplies installed. O N Integer Min Occurs: 0
Min Value: 0


Number of PSU for Redundancy High-end Performance Configuration Required if Product Family is Yes and the power supply unit (PSU) is redundant capable. O N Integer Min Occurs: 0
Min Value: 0


PSU 80Plus Platinum Certified High-end Performance Configuration Required if Product Family is Yes. Indicate if the power supply unit meets the criteria for the 80Plus Platinum Certification. O N Enumeration Data Min Occurs: 0

  • Yes
  • No

SERT Compress Eff. Score for High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT CryptoAES Efficiency Score High-end Performance Config Required if Product Family is Yes. Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT LU Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU LU Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SOR Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU SOR Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SORT Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU SORT Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SHA256 Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Flood Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Memory Flood Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Capacity Efficiency Score High-end Performance Config Required if Product Family is Yes. Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Sequential Efficiency Score High-end Performance Config Required if Product Family is Yes. Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Random Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Storage Random Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT SSJ Efficiency Score High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Idle Measurement (Watts) High-end Performance Configuration Required if Product Family is Yes. Indicate the SERT measured idle power in watts for this configuration. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Active State Efficiency Score High-end Performance Config Required if Product Family is Yes. Indicate the SERT Active State Efficiency Score as defined in ENERGY STAR Computer Servers V3, Equation 3. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Total Server Normal Perform. Score High-end Perform Config Required if Product Family is Yes. Indicate manufacturer reported total normalized performance component (numerator) used to calculate the configuration’s Active State Efficiency Score. O N Decimal Min Occurs: 0
No. of Decimal: 2


SERT Total Server Power Score (Watts) High-end Perform Config Required if Product Family is Yes. Indicate manufacturer reported total power component (denominator) used to calculate the configuration’s Active State Efficiency Score. O N Decimal Min Occurs: 0
No. of Decimal: 2


Tested Num. Blade Slots High-end Performance Configuration Required if Product Family is Yes and Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. O N Integer Min Occurs: 0
Min Value: 0