| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumeration Text |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner.
|
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name.
|
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction.
|
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body.
|
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification.
|
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Universal Product Code (UPC) |
Include UPC code(s) associated with the certified model, focusing on UPC codes featured in online listings. Do not include UPC codes if they are also associated with models not certified as ENERGY STAR. This field is available for all and required for select product categories unless not available. The UPC must be submitted as a string of digits when provided and should represent an actual UPC code. If not provided, the UPC code should be left blank and the reason for not including the UPC code will need to be submitted for the product to pass backend validation in EPA’s QPX system. |
O |
Y |
Text |
Min Occurs:
0
Max Occurs:
unbounded
Min Length: 6
Max Length: 16
|
|
| Reason for Not Providing UPC Code |
Required for select product categories if UPC code is not provided. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
- UPC Code Not Yet Assigned - CB Will Provide Later
- UPC Code Not Yet Assigned - Partner Will Provide Later
- No UPC Code Provided - Custom or Commercial Product
- UPC Code Is Also Associated with Models Not Certified as ENERGY STAR
- No UPC Code Provided - Other Reason
|
| Other Reason for Not Providing UPC Code |
Required if Reason for Not Providing UPC Code equals "No UPC code provided – Other Reason" .
|
O |
N |
Text |
Min Occurs:
0
Max Length: 2000
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers.
|
R |
Y |
|
Min Occurs:
0
Max Occurs:
unbounded
|
|
|
|
Provide each Additional Model Name as a separate data entry.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
|
|
Provide each Additional Model Number as a separate data entry.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs and retail numbers. UPC codes should not be included in this field. Provide each Additional Identifying Information as a separate data entry along with the corresponding model name and model number.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model.
|
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing.
|
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets.
|
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date.
|
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR.
|
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
Include information about one or more laboratories in which the model was tested.
|
R |
Y |
|
Min Occurs:
0
Max Occurs:
unbounded
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models.
|
O |
N |
Integer |
Min Occurs:
0
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 200
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
8
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 2000
|
|
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
|
| Tiled Display System |
Required if Product Type is Signage Display. Is the Signage Display model tested as a Tiled Display System? |
O |
N |
Enumeration Data |
Min Occurs:
0
|
|
| Maximum Tiled Configuration |
Required if Tiled Display System is Yes. Indicate the number of Signage Display panels in the Maximum Tiled Configuration. |
O |
N |
Integer |
Min Occurs:
0
|
|
| Panel Type |
|
R |
N |
Enumeration Data |
|
- TN LCD
- IPS LCD
- VA LCD
- OLED
- Plasma
- Other
|
| Other Panel Type |
Required if Panel Type is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Diagonal Screen Size (in) |
|
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Screen Area (sq in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Display Contrast Ratio |
Indicate the maximum display contrast ratio at 0 degrees from the perpendicular as an integer relative to 1 (e.g., report 100 if the contrast ratio is 100:1). |
R |
N |
Integer |
Min Value: 1
|
|
| Native Vertical Resolution (lines) |
|
R |
N |
Integer |
|
|
| Native Horizontal Resolution (lines) |
|
R |
N |
Integer |
|
|
| Total Native Resolution (megapixels) |
Multiply the Native Vertical Resolution by the Native Horizontal Resolution and divide by 1,000,000. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Native Pixel Density (Dp) (pixels/sq in) |
|
R |
N |
Integer |
|
|
| As-Tested Screen Refresh Rate (Hz) |
Indicate the screen refresh rate during the ENERGY STAR test. |
R |
N |
Integer |
|
|
| Maximum Screen Refresh Rate (Hz) |
Indicate the maximum refresh rate supported by the model. |
R |
N |
Integer |
|
|
| Enhanced Performance Criteria |
Indicate whether the model meets enhanced performance (EPD) criteria. Report this information regardless of whether the Total Energy Consumption allowance is needed to meet the ENERGY STAR requirements. |
R |
N |
Enumeration Data |
|
|
| Color Gamut |
Required if model meets enhanced performance criteria. Report Color Gamut supported by the model as percentage, 0.0 to 100.0%, to the nearest 0.1%, of the CIE LUV 1976 u' v' color space and calculated per Section 5.18 Gamut Area of the Information Display Measurements Standard Version 1.03. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 1
|
|
| Color Spaces Supported |
Indicate the color spaces fully supported (100%) by the model. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
6
|
- sRGB
- Adobe RGB
- NTSC
- DCI-P3
- None
- Other
|
| Reported Contrast Ratio at -85 deg. (Left) Horiz. Viewing Angle |
Required if the Monitor meets enhanced performance criteria. Provide the rated/reported display screen contrast ratio at a horizontal viewing angle of at least -85 degrees (left) from the perpendicular for a flat screen, and at least -83 degrees for a curved screen, with or without a screen cover glass. Indicate the contrast ratio as an integer relative to 1 (e.g., report 100 if the contrast ratio is 100:1). |
O |
N |
Integer |
Min Occurs:
0
Min Value: 1
|
|
| Reported Contrast Ratio at +85 deg. (Right) Horiz. Viewing Angle |
Required if the model meets enhanced performance criteria. Provide the rated/reported display screen contrast ratio at a horizontal viewing angle of at least +85 degrees (right) from the perpendicular for a flat screen, and at least 83 degrees for a curved screen, with or without a screen cover glass. Indicate the contrast ratio as an integer relative to 1 (e.g., report 100 if the contrast ratio is 100:1). |
O |
N |
Integer |
Min Occurs:
0
Min Value: 1
|
|
| High Dynamic Range (HDR) |
Indicate the HDR performance level for models that meet the VESA DisplayHDR CTS v1.0 Section 5.1 criteria. The model must meet the HDR performance level for all three white luminance criteria, including the 10% Center Patch Minimum Requirement (cd/m2), Full-screen Flash Minimum Requirement (cd/m2), and Full-screen Long-duration Minimum Requirement (cd/m2). Indicate N/A if the model does not meet the VESA DisplayHDR criteria. Report this information regardless of whether the HDR Total Energy Consumption allowance is needed to meet the ENERGY STAR requirements and regardless of whether HDR is enabled in the default as-shipped mode. |
R |
N |
Enumeration Data |
|
- DisplayHDR 400
- DisplayHDR 600
- DisplayHDR 1000
- N/A
|
| Available Signal or Data Interfaces |
Select all signal and data interfaces available with the model. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
9
|
- Display
- DVI
- HDMI
- RJ45
- RS232
- Thunderbolt
- USB
- VGA
- Other
|
| Other Available Interfaces |
Required if Available Interfaces is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Model Features |
Indicate all available features in the product. The features should include those not enabled during tests for ENERGY STAR certification. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
18
|
- Automatic Brightness Control
- Built-In Speakers
- Bluetooth
- Curved Screen
- Camera Interface
- Energy Gauge
- Full Network Connectivity
- Flash Memory-card/Smart-card Reader Gesture Recognition
- High Dynamic Range
- Occupancy Sensor
- Plug-in Module (Removable)
- Embedded Module (Non-removable)
- Touch Screen
- USB-C
- User Adjustable Backlight
- Variable Refresh Rate
- Other
- None
|
| Other Features |
Required if Model Features is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Features Enabled in Default On Mode |
Indicate features enabled in the default tested On Mode. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
12
|
- Automatic Brightness Control
- Built-In Speakers
- Bluetooth
- Camera Interface
- Energy Gauge
- Full Network Connectivity
- Gesture Recognition
- High Dynamic Range
- Occupancy Sensor
- Touch Screen
- Variable Refresh Rate
- None
|
| Features Enabled in Default Sleep Mode |
Indicate features enabled in the default tested Sleep Mode. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
6
|
- Bluetooth
- Energy Gauge
- Full Network Connectivity
- Occupancy Sensor
- Touch Screen
- None
|
| Signal Interface |
Provide the Signal Interface used for testing. |
R |
N |
Enumeration Data |
|
- DisplayPort 1.2
- DisplayPort 1.3
- DisplayPort 1.4
- DVI
- HDMI 1.4
- HDMI 2.0
- HDMI 2.1
- SVGA
- Thunderbolt
- USB-C
- VGA
- Other
|
| Other Interface |
Required if the Signal Interface used for testing is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Wireless Technologies Supported |
Indicate the wireless band and frequency supported by the model. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
8
|
- IEEE 802.11ac, 5 GHz
- IEEE 802.11n, 5 GHz
- IEEE 802.11n, 2.4 GHz
- IEEE 802.11g, 2.4 GHz
- IEEE 802.11b, 2.4 GHz
- IEEE 802.11a, 5 GHz
- Other
- None
|
| Ethernet Supported |
Indicate whether the model supports Ethernet. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
6
|
- Fast Ethernet (100 Mbit/s)
- Gigabit Ethernet (1000 Mbit/s)
- Fast Energy Efficient Ethernet (IEEE 802.3az)
- Gigabit Energy Efficient Ethernet (IEEE 802.3az)
- None
- Other
|
| USB-C with Power Delivery Supported |
Indicate whether the model has a USB-C port supporting Power Delivery. |
R |
N |
Enumeration Data |
|
|
| Maximum Power Delivery (W) |
Required if the model supports USB-C with Power Delivery. Provide the rated/reported maximum power which the model can deliver via USB-C connection. |
O |
N |
Integer |
Min Occurs:
0
Min Value: 0
|
|
| Power Source |
Indicate available power sources. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
5
|
- Ac to dc internal power supply
- Ac to dc external power supply
- Power over Ethernet (PoE)
- USB
- Other
|
| Other Power Source |
Required if the Power Source is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Does Model Have a Forced Menu at Initial Start-up? |
|
R |
N |
Enumeration Data |
|
|
| Maximum Measured Luminance (cd/m^2) |
Provide the maximum screen luminance of the On Mode setting in which the display controls, such as brightness and contrast level, are manually configured to a maximum level. Indicate the number in candelas per square meter. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Maximum Reported Luminance (cd/m^2) |
Provide the maximum screen luminance of the On Mode preset setting in which the display is brightest, as specified by the manufacturer, for example, in the user manual. Indicate the number in candelas per square meter, which will appear on the ENERGY STAR list of certified products. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| As-shipped Luminance (cd/m^2) |
Required for all models except models with Automatic Brightness Control (ABC) enabled by default. Indicate the number in candelas per square meter. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 1
|
|
| As-tested Luminance (cd/m^2) |
Luminance used for On Mode testing (LON). Indicate the number in candelas per square meter. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| On Mode Power at 12 Lux at 115 Volts (W) |
Required if ABC is enabled by default and the model was tested at 115 volts. Indicate the 115 volt power consumption at 12 lux ambient light conditions (P12) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| On Mode Power at 300 Lux at 115 Volts (W) |
Required if ABC is enabled by default and the model was tested at 115 volts. Indicate the 115 volt power consumption at 300 lux ambient light conditions (P300) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Measured On Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the measured On Mode power for products without ABC enabled by default or for models with ABC, but with the ABC disabled (PON) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Reported On Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the rated/reported Average On Mode Power at 115 volts, which will appear on the ENERGY STAR list of certified products, in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Maximum On Mode Power Limit for Signage Certification (W) |
Required if the model is a Signage Display. Provide the Maximum On Mode Power limit for Certification with applicable allowances included. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Measured Sleep Mode Power at 115 Volts (W) |
Required if the model was tested at 115 Volts. Provide the measured default Sleep Mode Power at 115 Volts (PSLEEP), in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Reported Sleep Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the rated/reported Average Sleep Mode Power at 115 volts, which will appear on the ENERGY STAR list of certified products, in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Measured Disconnected Sleep Mode Power at 115 Volts (W) |
Required if the model was tested with a data/network connection and at 115 volts. Provide the measured Sleep Mode Power with data/networking features deactivated and without any bridge connection established at 115 volts based on test data in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Maximum Sleep Mode Power Limit for Signage Certification (W) |
Required if the model is a Signage Display. Provide the Maximum Sleep Mode Power limit for Certification with applicable allowances included. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 1
Min Value: 0.5
Max Value: 6
|
|
| Number of Sleep Modes in Addition to Default Sleep Mode |
|
R |
N |
Enumeration Data |
|
|
| Mechanism for Automatically Entering Sleep or Off Mode? |
Indicate all mechanisms enabled by default that allow the model to automatically enter Sleep or Off Mode. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
4
|
- Display Power Management Signaling
- Timer
- Sensor
- Other
|
| Other Mechanism for Automatically Entering Sleep or Off Mode |
Required if Mechanism for Automatically Entering Sleep or Off Mode is Other. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Default Delay Time to Sleep (min) |
Required for products that have an internal default delay time after which the product transitions from On Mode to Sleep or Off Mode. Indicate the Default Delay Time to Sleep in minutes. |
O |
N |
Integer |
Min Occurs:
0
Min Value: 0
|
|
| Measured Off Mode Power at 115 Volts (W) |
Required if the model has an Off Mode and if it was tested at 115 volts. Provide the measured Off Mode Power at 115 volts (POFF) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
Max Value: 0.5
|
|
| Reported Off Mode Power at 115 Volts (W) |
Required if the model has an Off Mode and if it was tested at 115 volts. Provide the rated/reported Average Off Mode Power at 115 volts, which will appear on the ENERGY STAR list of certified products, in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
Max Value: 0.5
|
|
| Measured Total Energy Consumption at 115 Volts (kWh) |
Required if the model is a Monitor and was tested at 115 volts. Provide the Total Energy Consumption at 115 volts based on test data in kilowatt-hours. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Reported Total Energy Consumption at 115 Volts (kWh) |
Required if the model is a Monitor and was tested at 115 volts. Provide the rated/reported Total Energy Consumption at 115 volts, which will appear on the ENERGY STAR list of certified products, in kilowatt-hours. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Max Total Energy Consumption Limit for Monitor (kWh) |
Required if the model is a Monitor. Provide the Maximum Total Energy Consumption limit for certification with applicable allowances included. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 1
|
|
| On Mode Power at 12 Lux at 230 Volts (W) |
Required if ABC is enabled by default and the model was tested at 230 volts. Indicate the 230 volt power consumption at 12 lux ambient light conditions (P12) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| On Mode Power at 300 Lux at 230 Volts (W) |
Required if ABC is enabled by default and the model was tested at 230 volts. Indicate the 230 volt power consumption at 300 lux ambient light conditions (P300) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Measured On Mode Power at 230 Volts (W) |
Required if the model was tested at 230 volts. Provide the measured On Mode power for products without ABC enabled by default or for models with ABC, but with the ABC disabled (PON) in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Measured Sleep Mode Power at 230 Volts (W) |
Required if the model was tested at 230 volts. Provide the measured Sleep Mode Power at 230 volts (PSLEEP), in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Measured Disconnected Sleep Mode Power at 230 Volts (W) |
Required if the model was tested with a data/network connection and at 230 volts. Provide the measured Sleep Mode Power with data/networking features deactivated and without any bridge connection established at 230 volts based on test data in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| Measured Off Mode Power at 230 Volts (W) |
Required if the model has an Off Mode and if it was tested at 230 volts. Provide the measured Off Mode Power at 230 volts (POFF) based on test data in watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
Max Value: 0.5
|
|
| Measured Total Energy Consumption at 230 Volts (kWh) |
Required if the model is a Monitor and was tested at 115 volts. Provide the Total Energy Consumption at 230 volts based on test data in kilowatt-hours. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
|
|
| True Power Factor (PF) During On Mode Testing at 115 Volts (W) |
Required if the model was tested at 115 volts. Indicate the power factor (PF) averaged over the entire duration of On Mode testing. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| True Power Factor (PF) During On Mode Testing at 230 Volts (W) |
Required if the model was tested at 230 volts. Indicate the power factor (PF) averaged over the entire duration of On Mode testing. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
Max Value: 1.00
|
|