| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumeration Text |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner.
|
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name.
|
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction.
|
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body.
|
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification.
|
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Universal Product Code (UPC) |
Include UPC code(s) associated with the certified model, focusing on UPC codes featured in online listings. Do not include UPC codes if they are also associated with models not certified as ENERGY STAR. This field is available for all and required for select product categories unless not available. The UPC must be submitted as a string of digits when provided and should represent an actual UPC code. If not provided, the UPC code should be left blank and the reason for not including the UPC code will need to be submitted for the product to pass backend validation in EPA’s QPX system. |
O |
Y |
Text |
Min Occurs:
0
Max Occurs:
unbounded
Min Length: 6
Max Length: 16
|
|
| Reason for Not Providing UPC Code |
Required for select product categories if UPC code is not provided. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
- UPC Code Not Yet Assigned - CB Will Provide Later
- UPC Code Not Yet Assigned - Partner Will Provide Later
- No UPC Code Provided - Custom or Commercial Product
- UPC Code Is Also Associated with Models Not Certified as ENERGY STAR
- No UPC Code Provided - Other Reason
|
| Other Reason for Not Providing UPC Code |
Required if Reason for Not Providing UPC Code equals "No UPC code provided – Other Reason" .
|
O |
N |
Text |
Min Occurs:
0
Max Length: 2000
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission.
|
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers.
|
R |
Y |
|
Min Occurs:
0
Max Occurs:
unbounded
|
|
|
|
Provide each Additional Model Name as a separate data entry.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
|
|
Provide each Additional Model Number as a separate data entry.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs and retail numbers. UPC codes should not be included in this field. Provide each Additional Identifying Information as a separate data entry along with the corresponding model name and model number.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 255
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model.
|
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing.
|
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets.
|
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date.
|
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR.
|
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model.
|
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
Include information about one or more laboratories in which the model was tested.
|
R |
Y |
|
Min Occurs:
0
Max Occurs:
unbounded
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models.
|
O |
N |
Integer |
Min Occurs:
0
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 200
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
8
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided.
|
O |
N |
Text |
Min Occurs:
0
Max Length: 2000
|
|
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
Indicate for this model which type of EVSE describes it. |
R |
N |
Enumeration Data |
|
- Level 1
- Level 2
- Level 1/Level 2 Dual Input
|
| National Electric Code Product Safety Standards Met |
Indicate which safety standards are met by this model. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
3
|
|
| Network Protocol with Wake Capability |
Indicate which, if any, network protocols the model is shipped with, and None if the model does not have any network connected capability. You can select multiple network protocols if the model has the capability for multiple protocols. |
R |
Y |
Enumeration Data |
Min Occurs:
1
Max Occurs:
4
|
- Wi-Fi or Gigabit Ethernet
- Cellular
- Other LAN (Local Area Network)
- None
|
| Other LAN Network Protocol with Wake Capability |
Required if Network Protocol with Wake Capability is Other. Indicate what ‘other’ LAN protocol is present. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Network Protocol Enabled During Testing |
Required if one or multiple Network Protocols with Wake Capability were selected above. Indicate which capability, if any, is enabled by default/enabled during this testing. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
3
|
- Wi-Fi or Gigabit Ethernet
- Cellular
- Other LAN (Local Area Network)
|
| Other LAN Network Protocol Enabled During Testing |
Required if Network Protocol Enabled During Testing is Other. Indicate what ‘other’ LAN protocol is enabled. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Presence of Full Network Connectivity |
Indicate if there is presence of full network connectivity in Partial On Mode according to Section 4.1.1 of the specification. |
R |
N |
Enumeration Data |
|
|
| Input Cord Length (ft.) |
Enter input cord length used for test or mean cord length if it varies for multiple-input EVSE. Enter 0 if none. |
R |
N |
Integer |
Min Value: 0
|
|
| Input Cord Gauge (AWG) |
Enter American Wire Gauge (AWG) of the current-carrying line (L) and neutral (N) conductors used for test or mean conductor AWG if it varies. Enter N/A if none. |
R |
N |
Text |
Min Length: 1
Max Length: 4
|
|
| Output Cord Length (ft.) |
Enter output cord length used for test or mean cord length if it varies for multiple-input EVSE. Enter 0 if none. |
R |
N |
Integer |
Min Value: 0
|
|
| Output Cord Gauge (AWG) |
Enter American Wire Gauge (AWG) of the current-carrying line (L) and neutral (N) conductors used for test or mean conductor AWG if it varies. Enter N/A if none. |
R |
N |
Text |
Min Length: 1
Max Length: 4
|
|
| Screen Area, if EVSE has high res display (in2) |
Required if EVSE has a high resolution display. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Maximum (100%) Measured Luminance of the High Res Display |
Required if EVSE has a high resolution display (candelas per m2). |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Maximum (100%) Measured Luminance of the High Res Display Image |
Required if EVSE has a high resolution display. Indicate if the model displayed the three-bar pattern specified in IEC 62087:2011, Section 11.5.5 or if it displayed the default image that appears as-shipped. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
- IEC Test Pattern
- Default Image
|
| Measured Luminance at 65% of Max Brightness of High Res Display |
Required if EVSE has a high resolution display (candelas per m2). |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Automatic Brightness Control (ABC) Capable? |
Indicate if this model is capable of the self-acting mechanism that controls the brightness of a display or lamp as a function of ambient light. |
R |
N |
Enumeration Data |
|
|
| Automatic Brightness Control Enabled As-shipped? |
Required if model is ABC capable. Indicate Yes if model is shipped with this capability and it is enabled by default. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
|
| Connected Functionality Capable? |
This field is no longer relevant due to the updated connected criteria in the Version 1.1 specification and should not be used. Instead, Certification Bodies should use the Connected Functionality field. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
|
| Connected Functionality Capabilities Summary |
This field is no longer relevant due to the updated connected criteria in the Version 1.1 specification and should not be used. Instead, Certification Bodies should use the Product Features and Other Product Features fields to indicate any information that may be pertinent to consumers regarding connected functionality that is not already covered in other fields. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 4000
|
|
| Connected Functionality |
Indicate Yes if model meets all the V1.2 ENERGY STAR Connected Criteria as determined through examination of the product and/or product documentation. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
|
| Communication Hardware Architecture |
Required if Connected Functionality is Yes. Select all that apply. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
4
|
- A - Built-in
- B - Manufacturer-specific external communication module (s) and/or device (s)
- C - Open standards-based communication port on the appliance with open standards-based communication module
- D - Open standards-based communication port(s) on the appliance in addition to a, b, or c
|
| Communication Standard - Application Layer |
Required if Connected Functionality is Yes. Select all that apply. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
6
|
- Smart Energy Profile (SEP) 2.x
- OpenADR
- Open Charge Point Protocol (OCPP)
- 6LoWPAN
- Z-Wave
- CTA-2045
- Other
|
| Communication Standard - Application Layer Other |
Required if Communication Standard - Application Layer is Other. Indicate relevant standard(s). |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Communication Standard - Media/Network Layer |
Required if Connected Functionality is Yes. Select all that apply. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
7
|
- Wired Ethernet
- Wi-Fi
- HomePlug Green PHY
- 6LoWPAN
- Z-Wave
- CTA-2045
- Other
|
| Communication Standard - Media/Network Layer Other |
Required if Communication Standard - Media/Network Layer is Other. Indicate relevant standard(s). |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Primary Communication Module/Device Brand Name |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Primary Communication Module/Device Model Number |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Features Enabled By Primary Communication Module/Device |
This field is no longer relevant for V1.2. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
6
|
- User amenity (e.g. real time power reporting, remote management, user settings and messages)
- Open Charge Point Protocol (OCPP)
- Demand response via CTA-2045
- Demand response via OpenADR with on-premises VEN
- Demand response via OpenADR with cloud-based VEN
- Demand Response via SEP 2.x
|
| Secondary Communication Module/Device Brand Name |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Secondary Communication Module/Device Model Number |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Features Enabled By Secondary Communication Module/Device |
This field is no longer relevant for V1.2. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
5
|
- User amenity (e.g. real time power reporting, remote management, user settings and messages)
- Demand response via CTA-2045
- Demand response via OpenADR with on-premises VEN
- Demand response via OpenADR with cloud-based VEN
- Demand response via SEP 2.x
|
| Tertiary Communication Module/Device Brand Name |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Tertiary Communication Module/Device Model Number |
This field is no longer relevant for V1.2. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Features Enabled By Tertiary Communication Module/Device |
This field is no longer relevant for V1.2. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
5
|
- User amenity (e.g. real time power reporting, remote management, user settings and messages)
- Demand response via CTA-2045
- Demand response via OpenADR with on-premises VEN
- Demand response via OpenADR with cloud-based VEN
- Demand response via SEP 2.x
|
| Network Device Security Standards |
Required if Connected Functionality is Yes. Indicate all the standards and frameworks that apply to the Connected EVSE Product. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
8
|
- NIST Cybersecurity Framework
- NISTIR 8259A
- CSA Cybersecurity Verification Program
- ETSI EN 303 645
- ANSI/UL 2900
- UL IoT Security Rating (UL MCV 1376)
- CTA-2088
- Other
- None
|
| Network Device Security Standards - Other |
Required if Network Security Standards is Other. Identify the relevant network security standard(s) or framework(s). |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Description of System Cyber Security Measures |
Required if Connected Functionality is Yes. Describe measures taken by the EV Service Provider to support IT security (if any) for systems intended for home use, including company policy, compliance with published frameworks and standards, etc. This field is intended to capture measures beyond the implementation of security features at the device level. If there aren’t any security measures, specify none. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 2000
|
|
| Is Broadband Internet Connection Needed for Demand Response? |
Required if Connected Functionality is Yes. Indicate if Demand Response capabilities require broadband internet connection. |
O |
N |
Enumeration Data |
Min Occurs:
0
|
|
| Protocols Used to Support Smart Charging |
Required if Connected Functionality is Yes. Indicate whether the EVSE has the transceiver and/or necessary hardware to support smart charging (i.e. beyond simple managed charging with pulse width modulation or CANBus) by identifying which of the following station-to-vehicle protocol(s) the EVSE is capable of using to achieve smart charging capability. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
5
|
- ISO 15118-2 or later
- SAE J1772
- IEC 61851-1
- CHAdeMO 2.0
- Other
|
| Protocols Used to Support Smart Charging - Other |
Required if Protocols Used to Support Smart Charging is Other. Indicate relevant protocols. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 1000
|
|
| Auxiliary Product Features |
Required for all products certified to Version 1.2. Include all auxiliary features included in this product. Ensure that the total allowance includes adders for these features in No Vehicle Mode, Partial On Mode and Idle Mode respectively. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
8
|
- PLC Board (ISO 15118)
- Credit Card Reader
- Revenue Grade Meter
- Radio Frequency Identification (RFID)
- Speaker
- Camera/ Occupancy Sensing
- High Resolution Display
- None
|
| Product Features |
Indicate additional product features important to consumers beyond those included in the Auxiliary Product Features field. |
O |
Y |
Enumeration Data |
Min Occurs:
0
Max Occurs:
8
|
- Vehicle to grid capability
- Model is portable
- PV integration capability
- Battery storage integration capability
- Smart Home Energy Management System (SHEMS) compatibility
- Wireless power transfer capability
- Other
- None
|
| Other Product Features |
Required if Other is selected from Product Features. Include and describe other product features important to consumers. |
O |
N |
Text |
Min Occurs:
0
Min Length: 0
Max Length: 4000
|
|
| Max Nameplate Output Current (A) |
Indicate the Maximum Nameplate Output Current for every model. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Dual Input Max Nameplate Output Current (A) |
Required for dual-input Level 1/2 models, indicate the Level 2 Maximum Nameplate Output Current. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Input Voltage (V) |
Indicate the Input Voltage for every model. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
Y |
Decimal |
Min Occurs:
1
Max Occurs:
unbounded
No. of Decimal: 2
|
|
| Dual Input Voltage (V) |
Required for dual-input Level 1/2 models, indicate the Level 2 Input Voltage. |
O |
Y |
Decimal |
Min Occurs:
0
Max Occurs:
unbounded
No. of Decimal: 2
|
|
| Number of Outputs |
Indicate the number of outputs available for every model. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Integer |
Min Value: 0
Max Value: 20
|
|
| Dual Input Number of Outputs |
Required for dual-input Level 1/2 models, indicate the Level 2 number of outputs available. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance for ABC Room Illuminance (lux) |
Required for models with ABC enabled during testing (in the high illuminance condition of 300 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default No Vehicle Mode Input Power |
Indicate the No Vehicle Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| No Vehicle Mode Total Allowance (W) |
Indicate the No Vehicle Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default No Vehicle Mode Power Factor |
Indicate the No Vehicle Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default Partial On Mode Input Power |
Indicate the Partial On Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Partial On Mode Total Allowance (W) |
Indicate the Partial On Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default Partial On Mode Power Factor |
Indicate the Partial On Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default Idle Mode Input Power (W) |
Indicate the Idle Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Idle Mode Total Allowance (W) |
Indicate the Idle Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance for ABC or Default Idle Mode Power Factor |
Indicate the Idle Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Full Current Operation Mode Test: UUT Available Current |
Indicate the Full Current Operation Mode Test: UUT Available Current. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance Full Current Operation Mode: Input Power |
Indicate the Full Current Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance Full Current Operation Mode: Output Power |
Indicate the Full Current Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| High Illuminance 30 A Operation Mode: Input Power |
Required if Full Current is ≥ 30 A. Indicate the 30 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance 30 A Operation Mode: Output Power |
Required if Full Current is ≥ 30 A models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance 15 A Operation Mode Test: Input Power |
Required if Full Current is ≥ 15 A. Indicate the 15 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance 15 A Operation Mode Test: Output Power |
Required if Full Current is ≥ 15 A. Indicate the 15 A Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance 4 A Operation Mode Test: Input Power |
Required if Full Current is ≥ 4 A. Indicate the 4 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| High Illuminance 4 A Operation Mode Test: Output Power |
Required if Full Current is ≥ 4 A. Indicate the 4 A Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance for ABC Room Illuminance (lux) |
Required for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance No Vehicle Mode Input Power (W) |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance No Vehicle Mode Power Factor |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in No Vehicle Mode. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Partial On Mode Input Power (W) |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Partial On Mode Power Factor |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in Partial On Mode. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Idle Mode Input Power (W) |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Idle Mode Power Factor |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in Idle Mode. For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Full Current Mode Test: Input Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance Full Current Operation Mode Test: Output Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 30 A Operation Mode Test: Input Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 30 A Operation Mode Test: Output Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 15 A Operation Mode Test: Input Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 15 A Operation Mode Test: Output Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 4 A Operation Mode Test: Input Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Low Illuminance 4 A Operation Mode Test: Output Power |
Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance for ABC Room Illuminance (lux) |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the high illuminance condition of 300 lux). Indicate the Level 2 ABC Room Illuminance value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance No Vehicle ModeInput Power (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input No Vehicle Mode Total Allowance (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Total Allowance value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance No Vehicle Mode Power Factor |
Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance Partial On Mode Input Power (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Partial On Mode Total Allowance (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Total Allowance value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance Partial On Mode Power Factor |
Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance Idle Mode Input Power (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Idle Mode Total Allowance (W) |
Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Total Allowance value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance Idle Mode Power Factor |
Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Full Current Operation Mode Test Available Current |
Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: UUT Available Current value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. Full Current Operation Mode Input Power |
Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. Full Current Operation ModeOutput Power |
Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. 30 A Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models, indicate the Level 2 30 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. 30 A Operation Mode Test: Output Power |
Required for dual-input Level 1/2 models, indicate the Level 2 30 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. 15 A Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models, indicate the Level 2 15 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illumin. 15 A Operation Mode Test: Output Power |
Required for dual-input Level 1/2 models, indicate the Level 2 15 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance 4 A Operation Mode: Input Power |
Required for dual-input Level 1/2 models, indicate the Level 2 4 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input High Illuminance 4 A Operation Mode: Output Power |
Required for dual-input Level 1/2 models, indicate the Level 2 4 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance for ABC Room Illuminance (lux) |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 ABC Room Illuminance value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance No Vehicle Mode Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 No Vehicle Mode Input Power value in Watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance No Vehicle Mode Power Factor |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 No Vehicle Mode Power Factor value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance Partial On Mode Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Partial On Mode Input Power value in Watts. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance Partial On Mode Power Factor |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Partial On Mode Power Factor value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance Idle Mode Input Power (W) |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Idle Mode Input Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illuminance Idle Mode Power Factor |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Idle Mode Power Factor value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. Current Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Full Current Operation Mode Test: Input Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. Current Operation Mode Test:Output Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Full Current Operation Mode Test: Output Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 30 A Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 30 A Operation Mode Test: Input Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 30 A Operation Mode Test: Output Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 30 A Operation Mode Test: Output Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 15 A Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 15 A Operation Mode Test: Input Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 15 A Operation Mode Test: Output Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 15 A Operation Mode Test: Output Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 4 A Operation Mode Test: Input Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 4 A Operation Mode Test: Input Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|
| Dual Input Low Illumin. 4 A Operation Mode Test: Output Power |
Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 4 A Operation Mode Test: Output Power value. |
O |
N |
Decimal |
Min Occurs:
0
No. of Decimal: 2
|
|