Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

ENERGY STAR
Utility Navigation
  • About
  • For Partners
Main navigation
  • Find Products
    • Product Finder
    • Rebate Finder
    • Ask the Experts
    • Product Specification Search
    • Best Value Finder
    • Frequently Asked Questions
  • Save at Home
    • Heat & Cool Efficiently
    • Seal and Insulate
    • Expert Home Improvements
  • New Homes
    • Find a Builder
    • Homeowner Benefits
    • Join as a Partner
    • Program Requirements
    • Residential Resources
    • § 45L Builder Tax Credit
    • ENERGY STAR NextGen
    • About Us
  • Commercial Buildings
    • Benchmark
    • Save Energy
    • Earn Recognition
    • Resources by Audience
    • Resources by Topic
    • Training
    • About Us
  • Industrial Plants
    • Industrial Partnership
    • Industrial Assistance Network
    • Plant Certification
    • Challenge for Industry
    • Industries in Focus
    • Treasure Hunt
    • Get started with ENERGY STAR
    • Program Administrators
    • Service & Product Providers
    • Decarbonizing Industry
Breadcrumb
  1. Home
  2. Energy Efficient Products
  3. Data Center Equipment
  4. 5 Simple Ways To Avoid Energy Waste In Your Data Center
  5. Raise the Temperature

AIR CLEANERS

AIR-SOURCE HEAT PUMPS

AUDIO/VIDEO

BOILERS

CEILING FANS

CENTRAL AIR CONDITIONER

CLOTHES DRYERS

CLOTHES WASHERS

COMMERCIAL BOILERS

COMMERCIAL CLOTHES WASHERS

Commercial Food Service Equipment

COMMERCIAL WATER HEATERS

COMPUTERS

DECORATIVE LIGHT STRINGS

DEHUMIDIFIERS

DATA CENTER STORAGE

DATA CENTERS

DIGITAL MEDIA PLAYER

Data Center Equipment

  • Embedded Data Centers
  • 5 Simple Ways to Avoid Energy Waste in Your Data Center
    • Raise the Temperature
    • Virtualize Servers
    • Identify and Remove Unused Servers
    • Replace Standard Fans with Variable Speed Fans
    • Institute an ENERGY STAR Purchasing Policy
  • 16 More Ways to Cut Energy Waste in the Data Center
  • The Energy Cost of Cryptocurrency
  • Data Centers for Utilities
  • IT Solutions and Power Infrastructure
  • Optimize Airflow and HVAC

DUCTLESS HEATING & COOLING

ELECTRIC COOKING PRODUCTS

ELECTRIC VEHICLE CHARGERS

ENTERPRISE SERVERS

FREEZERS

FURNACES

GEOTHERMAL HEAT PUMPS

HEAT PUMP WATER HEATERS

HIGH EFFICIENCY GAS STORAGE WATER HEATERS

IMAGING EQUIPMENT

LABORATORY GRADE REFRIGERATORS AND FREEZERS

LARGE NETWORK EQUIPMENT

LIGHT COMMERCIAL HEATING & COOLING

LIGHT FIXTURES

MONITORS

POOL PUMPS

REFRIGERATORS

RESIDENTIAL WINDOWS, DOORS & SKYLIGHTS

ROOM AIR CONDITIONERS

Seal and Insulate with ENERGY STAR for Partners

SIGNAGE DISPLAYS

SMART HOME ENERGY MANAGEMENT SYSTEMS

SMART THERMOSTATS

SOLAR WATER HEATERS

STORM WINDOWS

TELEPHONES

TELEVISIONS

UNINTERRUPTIBLE POWER SUPPLIES

VENDING MACHINES

VENTILATION FANS

VOICE OVER INTERNET PROTOCOL (VOIP) PHONES

WATER COOLERS

WHOLE HOME TANKLESS GAS WATER HEATERS

Demand Hot Water Recirculating System

Cool Roofs

Rooftop Solar

Green Power Options

Programs and Strategies for Energy Access

Energy Efficiency Home Upgrade Assistance

Inclusive Utility Investment

Product Specifications & Partner Commitments Search

Products Tools and Resources

Recycle

Save on Heating Costs with ENERGY STAR This Season

Scoping Reports

Smart Home Tips for Saving Energy

DIY Lighting with ENERGY STAR

Eligible Commercial Fixture Types

Learn About Brightness

Learn About LED Lighting

Medical Imaging Equipment For Partners

Recent Program Updates

Save Energy in the Data Center / Server Room: Additional Resources

The Certified Lighting Subcomponent Database (CSD)

Earth Day 2023

Enjoy Spring Savings and Help the Planet

Keep Your Cool AND Save Your Money this Summer

Gifts that Do a World of Good

Most Efficient

Raise the Temperature

You Should Not Feel Cold in Your Data Center

Fifteen to twenty years ago it wasn’t unusual to put on a jacket or sweater upon entering a data center.  In fact, some data center operators installed coat hangers and kept spare jackets by the entrance for exactly that purpose.  At the time, data centers set thermostats as low as 55 degrees F.  Today, if you walk into your data center and find it noticeably colder than the rest of the building, chances are good that you can save energy by raising the temperature.

At what temperature should a data center be operated?  In 2008, the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) expanded the recommended temperature range from 68°F to 77°F (the 2004 level) to 64.4°F to 80.6°F – as measured at the inlet (or front) of the server.  Some data centers can be run at higher temperatures.

Server Inlet Temps
Figure 1: Recommended server inlet temperatures

Although any data center will save energy by raising temperatures, data centers with air-side or water-side economizers and/or variable speed fan drives in their cooling units stand to benefit the most. That's because higher set point temperatures increase the amount of time that: 1) outdoor air can be used for cooling, and 2) cooling units can run at reduced fan speeds.

Modern Equipment Can Handle Higher Temperatures

Most recent data center equipment is rated for a maximum inlet temperature of 95 degrees F.  For example, the Dell Power Edge R7301  and the HP ProLiant DL 580 Gen 8 servers2 both have upper temperature limits of 95°F. Some servers have limits as high as 113°F or more3, making them ideal for data centers that rely on outdoor air year round for cooling.

Savings and Costs

Data centers can save 4% to 5% in energy costs for every 1°F increase in server inlet temperature.  As a result, raising server inlet temperatures has been a key component of many data center energy efficiency efforts:

  • BNY Mellon, an ENERGY STAR certified data center, raised the temperature of their “supply air” (air exiting the cooling unit) from 72 to 78 degrees F, which allowed them to increase their chilled water temperature from 44 to 47 degrees F, lowering cooling costs. Their story is featured in an ENERGY STAR case study (PDF, 600 KB).
  • RagingWire, an ENERGY STAR certified data center, raised their chilled water temperature from 50 to 60 degrees F after installing hot aisle containment. An extensive wireless sensor network was installed to monitor and maintain appropriate server inlet temperatures. The project paid for itself in a year, and their story is featured in an ENERGY STAR case study.
  • The Green Grid completed a comprehensive analysis (PDF, 2 KB) detailing the return on investment (ROI) and power usage effectiveness (PUE) associated with several data center efficiency upgrades. The payback for adding airflow management devices such as baffles and blanking panels, repositioning temperature/humidity sensors, and adjusting temperature set points was just 29 months.
  • Google’s Green Data Centers: Network POP Case Study (PDF, 4 KB) documents specific energy efficiency measures taken in a server room.  Measures included temperature and humidity adjustments, optimized air vent tiles, cold aisle containment, and CRAC air return extensions.  The initiative had a return on investment (ROI) of less than one year.

Tips and Considerations

  • Although adjusting inlet temperature is relatively simple, metering temperature, humidity and power changes across the data center can be complicated. Contact a firm specializing in data center monitoring for assistance.
  • Raising inlet temperature may lead to uncomfortable working conditions. For example, at the higher end of ASHRAE's operating range, the cold aisle (server inlet) temperature might be 80.6°F, but the neighboring hot aisle temperature could be as high as 105°F to 110°F.
  • The highest recommended server inlet temperature setting may not be the most efficient. A study by Dell4 revealed that higher server inlet temperatures can cause internal server fans to automatically speed up, resulting in increased overall energy use.  The study recommended server inlet temperatures between the upper 70s and lower 80s (degrees F) to prevent this from happening.
  • Raising temperatures may lead to data center “hot spots,” or areas receiving insufficient cool air.  Hot spots can lead to equipment failure if maximum operating temperatures are exceeded.  ASHRAE recommends measuring and recording server inlet temperatures at the center of the top, middle and bottom of server racks, at about 2 inches from the front of the equipment.5   See Figure 2.  This helps ensure that you don’t miss hot spots on server racks.

    Where to Measure Server Inlet Temps
    Figure 2: Where to measure server inlet temperatures
  • One way to identify hot spots is through thermal imaging. All objects emit infrared radiation based on their temperatures; thermal imaging makes it possible to view equipment temperature conditions which are invisible to the naked eye. The hotter an object is, the more it radiates, allowing infrared (or thermal) imaging to assess cooling and air flow problems in the data center.  In addition to identifying hot spots, thermal imaging can locate “cold spots,” where equipment is receiving too much cool air, wasting energy.  (As a bonus, thermal imaging can also identify overloaded circuits and loose connections before they result in unplanned outages.)  With knowledge gleaned from thermal imaging, data center managers can adjust airflow management devices (e.g., vented floor tiles, diffusers) and cooling equipment to reduce hot and cold spots—ultimately reducing the amount of time cooling units need to run. Figure 3 below shows a row of server racks with cold air (depicted in blue) coming up through perforated floor tiles.  The temperature gradient visibly increases as air moves from the bottom to the top of the racks, becoming hotter (and transitioning from yellow, to orange, to red) along the way.

    Infrared Image

    Figure 3: Infrared image showing temperature gradients across server racks.  
    Photo credit: Thermal Imaging Services, LLC.


1 https://www.dell.com/support/manuals/us/en/04/poweredge-r730xd/r730xd_ompublication/standard-operating-temperature?guid=guid-c5c1a8e6-c380-46ea-a788-604fd8778370&lang=en-us

2 https://support.hpe.com/hpsc/doc/public/display?docId=c04142791

3 Jon Fitch. Dell’s Next Generation Servers: Pushing the Limits of Data Center Cooling Cost Savings. February 2012. http://www.dell.com/downloads/global/products/pedge/data_center_cooling_fresh_air.pdf (PDF, 838 KB)

4 David Moss, Data Center Operating Temperature: The Sweet Spot.  June 2011. 

5 https://www.raritan.com/blog/detail/ashrae-colder-is-not-better-for-a-data-center

ENERGY STAR
United States Environmental Protection Agency

Save Energy.

  • Find Products
  • Save at Home
  • New Homes
  • Commercial Buildings
  • Industrial Plants
  • Partner Resources

Learn More.

  • About Us
  • Join
  • Newsroom
  • Privacy
  • Accessibility Statement
  • Help Desk

Stay Informed.

  • Public Notices
  • Consumer Newsletter
  • Program Updates
Back to top