Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

ENERGY STAR
Utility Navigation
  • About
  • For Partners
Main navigation
  • Find Products
    • Product Finder
    • Rebate Finder
    • Ask the Experts
    • Product Specification Search
    • Best Value Finder
    • Frequently Asked Questions
  • Save at Home
    • Heat & Cool Efficiently
    • Seal and Insulate
    • Expert Home Improvements
  • New Homes
    • Find a Builder
    • Homeowner Benefits
    • Join as a Partner
    • Program Requirements
    • Residential Resources
    • § 45L Builder Tax Credit
    • ENERGY STAR NextGen
    • About Us
  • Commercial Buildings
    • Benchmark
    • Save Energy
    • Earn Recognition
    • Resources by Audience
    • Resources by Topic
    • Training
    • About Us
  • Industrial Plants
    • Industrial Partnership
    • Industrial Assistance Network
    • Plant Certification
    • Challenge for Industry
    • Industries in Focus
    • Treasure Hunt
    • Get started with ENERGY STAR
    • Program Administrators
    • Service & Product Providers
    • Decarbonizing Industry
Breadcrumb
  1. Home
  2. Energy Efficient Products
  3. Data Center Equipment
  4. 16 More Ways To Cut Energy Waste In The Data Center
  5. Reduce Energy Losses from Power Distribution Units (PDUs)

AIR CLEANERS

AIR-SOURCE HEAT PUMPS

AUDIO/VIDEO

BOILERS

CEILING FANS

CENTRAL AIR CONDITIONER

CLOTHES DRYERS

CLOTHES WASHERS

COMMERCIAL BOILERS

COMMERCIAL CLOTHES WASHERS

Commercial Food Service Equipment

COMMERCIAL WATER HEATERS

COMPUTERS

DECORATIVE LIGHT STRINGS

DEHUMIDIFIERS

DATA CENTER STORAGE

DATA CENTERS

DIGITAL MEDIA PLAYER

Data Center Equipment

  • Embedded Data Centers
  • 5 Simple Ways to Avoid Energy Waste in Your Data Center
  • 16 More Ways to Cut Energy Waste in the Data Center
    • Consolidate Lightly-utilized Servers
    • Implement Efficient Data Storage Measures
    • Utilize Built-in Server Power Management Features
    • Reduce Energy Losses from Power Distribution Units (PDUs)
    • Reduce Energy Loss from Uninterruptible Power Supply Systems
    • Manage Airflow for Cooling Efficiency
    • Move to a Hot Aisle/Cold Aisle Layout
    • Utilize Containment/Enclosures
    • Consider Water Side Economizers
    • Install In-rack or In-row Cooling
    • Make Humidification Adjustments
    • Use an Air-Side Economizer
    • Use Sensors and Controls - Match Cooling, Airflow, IT Loads
    • Provide Energy-efficiency Awareness Training
    • Select a Sustainable Colocation Facility
  • The Energy Cost of Cryptocurrency
  • Data Centers for Utilities
  • IT Solutions and Power Infrastructure
  • Optimize Airflow and HVAC

DUCTLESS HEATING & COOLING

ELECTRIC COOKING PRODUCTS

ELECTRIC VEHICLE CHARGERS

ENTERPRISE SERVERS

FREEZERS

FURNACES

GEOTHERMAL HEAT PUMPS

HEAT PUMP WATER HEATERS

HIGH EFFICIENCY GAS STORAGE WATER HEATERS

IMAGING EQUIPMENT

LABORATORY GRADE REFRIGERATORS AND FREEZERS

LARGE NETWORK EQUIPMENT

LIGHT COMMERCIAL HEATING & COOLING

LIGHT FIXTURES

MONITORS

POOL PUMPS

REFRIGERATORS

RESIDENTIAL WINDOWS, DOORS & SKYLIGHTS

ROOM AIR CONDITIONERS

Seal and Insulate with ENERGY STAR for Partners

SIGNAGE DISPLAYS

SMART HOME ENERGY MANAGEMENT SYSTEMS

SMART THERMOSTATS

SOLAR WATER HEATERS

STORM WINDOWS

TELEPHONES

TELEVISIONS

UNINTERRUPTIBLE POWER SUPPLIES

VENDING MACHINES

VENTILATION FANS

VOICE OVER INTERNET PROTOCOL (VOIP) PHONES

WATER COOLERS

WHOLE HOME TANKLESS GAS WATER HEATERS

Demand Hot Water Recirculating System

Cool Roofs

Rooftop Solar

Green Power Options

Programs and Strategies for Energy Access

Energy Efficiency Home Upgrade Assistance

Inclusive Utility Investment

Product Specifications & Partner Commitments Search

Products Tools and Resources

Recycle

Save on Heating Costs with ENERGY STAR This Season

Scoping Reports

Smart Home Tips for Saving Energy

DIY Lighting with ENERGY STAR

Eligible Commercial Fixture Types

Learn About Brightness

Learn About LED Lighting

Medical Imaging Equipment For Partners

Recent Program Updates

Save Energy in the Data Center / Server Room: Additional Resources

The Certified Lighting Subcomponent Database (CSD)

Earth Day 2023

Enjoy Spring Savings and Help the Planet

Keep Your Cool AND Save Your Money this Summer

Gifts that Do a World of Good

Most Efficient

Reduce Energy Losses from Power Distribution Units (PDUs)

Power Distribution Units (PDUs) deliver conditioned power from the uninterruptable power supply (UPS) system to servers, networking equipment and other electronic devices in the data center.  PDUs are part of a data center’s electrical distribution system, which includes utility or generator-supplied power, building switchgear and transformers, and UPS systems.  Although they are often overlooked, electrical distribution system losses can account for 10% to 12% of the total energy consumed by the data center, on average.1 

Data centers may deploy one or two types of PDUs: 

  1. PDUs may simply be well-constructed power strips.  However, today’s “smart,” or “intelligent”, PDUs allow data center managers to remotely monitor real-time power use, data and event logs, current drawn by each PDU, and current drawn by each outlet.  Some can remotely perform on/off switching for each outlet as well.  These units improve our understanding of energy-use, can help identify comatose servers, can inform capacity planning, and may alert us to equipment failure.
  2. Floor-mounted PDUs traditionally contain isolation transformers that reduce high voltage and current to more common and useful levels, which they feed downstream to rack-based PDUs.  (For example, they might reduce electricity entering the data center at 240 volts and 30 amps in a single phase to multiple 120 volt 15 amp or 120 volt 20 amp plugs.  Floor-mounted PDUs may be integrated with monitoring software to trend power consumption and help plan for future power needs.

Use PDUs with high-efficiency transformers

If your data center uses floor-mounted PDUs, know that PDUs containing high-efficiency transformers are 2% to 3% more efficient overall compared to a PDUs with generic lower-efficiency transformers.

Monitor individual devices to identify energy-efficiency problems and opportunities

Because “smart” PDUs can tell you how much power each device uses, you can easily identify the energy hogs.  PDUs can also identify equipment that is no longer needed. For example, when a PDU indicates that a certain server is running at an average of 35% of peak power, you’ll be able to earmark that server as a candidate for decommissioning.2

A failed power supply, a significant temperature increase, a sudden surge in power usage -- these changes can all be identified by an intelligent PDU.  Some PDUs can send you an alert when something is perceived to be outside normal operating conditions.  For example, when a PDU is reaching its total power capacity, it can alert the data center manager before breaker capacity is reached, letting him/her know that it’s time to bring in more PDUs to prevent outages.

Monitor power consumption to improve capacity planning

PDUs allow you to monitor rack-level power consumption, store the data, trend it, and use it to make decisions about your data center.

For example, suppose you have concerns about reaching the upper limits of power capacity in your facility.  “Smart” PDUs perform outlet-level monitoring, which allows you to pinpoint areas within the data center where a simple equipment rearrangement may free up power capacity.

Turn off unloaded PDUs

Like other equipment in the data center, PDUs should be turned off if they are not in use.  In some facilities, the array of UPS modules and/or PDUs has more than enough capacity to serve the IT load. It may be possible to shut down some modules and still retain the required level of redundancy.3 This will allow the remaining units to operate at a higher load factor, which usually translates to higher efficiency.4  Learn more about reducing energy losses from uninterruptable power supply (UPS) systems.

Maintain balanced PDU loads

Unbalanced electric loads in 3-phase systems cause higher current flows between the legs of the transformer, resulting in waste heat and less efficient transformer operation.5  Redistribute the loads to improve balance. If the transformer is in an air-conditioned space, the reduced waste heat will also reduce the load on the cooling system.

Benchmark your efficiency by calculating PUE

Power data obtained from PDUs can help you calculate Power Usage Effectiveness for your data center.  PUE is a widely accepted benchmarking standard that helps managers determine how effectively data centers use electricity. It provides insights into efficiency efforts, and can also help determine when something has gone awry.

PUE is the ratio of total energy used by a data center facility to the energy delivered to IT equipment – see Figure 1, below.  Total power used in each rack, as reported by PDUs, can be compared to the building’s overall power usage to calculate PUE.  PUE approaches 1 as the data center becomes more efficient.  A 2014 survey6 by the Uptime Institute indicated that the average reported PUE is 1.7.  Learn more about benchmarking your data center’s energy efficiency. 

PUE Example
Figure 1: How Power Usage Effectiveness (PUE) is calculated. A PUE of 3.0 indicates a relatively inefficient data center. Image credit: DataClean.

Savings and Costs

PDUs containing high-efficiency transformers are 2% to 3% more efficient overall compared to a PDUs with generic lower-efficiency transformers.

Target, in one of their two ENERGY STAR certified data centers, powered down two unloaded 300 kVA PDUs to save 261,000 kWh annually. Read their case study (PDF, 609 KB) to learn more.

Tips and Considerations

Data center infrastructure management (DCIM) systems help make the most of smart PDUs.  For example, a single DCIM dashboard can offer real-time power loads, trends, and capacity forecasts. They can also help drive efficiency initiatives with real-time PUE gauges.


1 Evaluating UPS System Efficiency, by K. Kutsmeda, Consulting-Specifying Engineer, June 11, 2015. http://www.csemag.com/single-article/evaluating-ups-system-efficiency/73497ade33f9a66ead63a77f33e94d4e.html

2 5 Ways to Improve Data Center Energy Efficiency with PDUs, The Right Signals Blog, Belden.com, March 10, 2016. https://www.belden.com/Blogs/improving-energy-efficiency-with-pdus

3 Redundancy refers to the duplication of critical components or functions of a system with the intention of increasing reliability.

4 Data Center Master List of Energy Efficiency Actions, Center of Expertise for Energy Efficiency in Data Centers, Lawrence Berkley National Laboratory, US Department of Energy, Feb. 11, 2016. https://datacenters.lbl.gov/resources/data-center-master-list-energy

5 Data Center Master List of Energy Efficiency Actions, Center of Expertise for Energy Efficiency in Data Centers, Lawrence Berkley National Laboratory, US Department of Energy, Feb. 11, 2016. https://datacenters.lbl.gov/resources/data-center-master-list-energy

6 2014 Data Center Industry Survey, Uptime Institute. 2014.  Available online at: https://journal.uptimeinstitute.com/2014-data-center-industry-survey/

ENERGY STAR
United States Environmental Protection Agency

Save Energy.

  • Find Products
  • Save at Home
  • New Homes
  • Commercial Buildings
  • Industrial Plants
  • Partner Resources

Learn More.

  • About Us
  • Join
  • Newsroom
  • Privacy
  • Accessibility Statement
  • Help Desk

Stay Informed.

  • Public Notices
  • Consumer Newsletter
  • Program Updates
Back to top