Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

ENERGY STAR
Utility Navigation
  • About
  • For Partners
Main navigation
  • Find Products
    • Product Finder
    • Rebate Finder
    • Ask the Experts
    • Product Specification Search
    • Best Value Finder
    • Frequently Asked Questions
  • Save at Home
    • Heat & Cool Efficiently
    • Seal and Insulate
    • Expert Home Improvements
  • New Homes
    • Find a Builder
    • Homeowner Benefits
    • Join as a Partner
    • Program Requirements
    • Residential Resources
    • § 45L Builder Tax Credit
    • ENERGY STAR NextGen
    • About Us
  • Commercial Buildings
    • Benchmark
    • Save Energy
    • Earn Recognition
    • Resources by Audience
    • Resources by Topic
    • Training
    • About Us
  • Industrial Plants
    • Industrial Partnership
    • Industrial Assistance Network
    • Plant Certification
    • Challenge for Industry
    • Industries in Focus
    • Treasure Hunt
    • Get started with ENERGY STAR
    • Program Administrators
    • Service & Product Providers
    • Decarbonizing Industry
Breadcrumb
  1. Home
  2. Energy Efficient Products
  3. Data Center Equipment
  4. 16 More Ways To Cut Energy Waste In The Data Center
  5. Utilize Containment/Enclosures

AIR CLEANERS

AIR-SOURCE HEAT PUMPS

AUDIO/VIDEO

BOILERS

CEILING FANS

CENTRAL AIR CONDITIONER

CLOTHES DRYERS

CLOTHES WASHERS

COMMERCIAL BOILERS

COMMERCIAL CLOTHES WASHERS

Commercial Food Service Equipment

COMMERCIAL WATER HEATERS

COMPUTERS

DECORATIVE LIGHT STRINGS

DEHUMIDIFIERS

DATA CENTER STORAGE

DATA CENTERS

DIGITAL MEDIA PLAYER

Data Center Equipment

  • Embedded Data Centers
  • 5 Simple Ways to Avoid Energy Waste in Your Data Center
  • 16 More Ways to Cut Energy Waste in the Data Center
    • Consolidate Lightly-utilized Servers
    • Implement Efficient Data Storage Measures
    • Utilize Built-in Server Power Management Features
    • Reduce Energy Losses from Power Distribution Units (PDUs)
    • Reduce Energy Loss from Uninterruptible Power Supply Systems
    • Manage Airflow for Cooling Efficiency
    • Move to a Hot Aisle/Cold Aisle Layout
    • Utilize Containment/Enclosures
    • Consider Water Side Economizers
    • Install In-rack or In-row Cooling
    • Make Humidification Adjustments
    • Use an Air-Side Economizer
    • Use Sensors and Controls - Match Cooling, Airflow, IT Loads
    • Provide Energy-efficiency Awareness Training
    • Select a Sustainable Colocation Facility
  • The Energy Cost of Cryptocurrency
  • Data Centers for Utilities
  • IT Solutions and Power Infrastructure
  • Optimize Airflow and HVAC

DUCTLESS HEATING & COOLING

ELECTRIC COOKING PRODUCTS

ELECTRIC VEHICLE CHARGERS

ENTERPRISE SERVERS

FREEZERS

FURNACES

GEOTHERMAL HEAT PUMPS

HEAT PUMP WATER HEATERS

HIGH EFFICIENCY GAS STORAGE WATER HEATERS

IMAGING EQUIPMENT

LABORATORY GRADE REFRIGERATORS AND FREEZERS

LARGE NETWORK EQUIPMENT

LIGHT COMMERCIAL HEATING & COOLING

LIGHT FIXTURES

MONITORS

POOL PUMPS

REFRIGERATORS

RESIDENTIAL WINDOWS, DOORS & SKYLIGHTS

ROOM AIR CONDITIONERS

Seal and Insulate with ENERGY STAR for Partners

SIGNAGE DISPLAYS

SMART HOME ENERGY MANAGEMENT SYSTEMS

SMART THERMOSTATS

SOLAR WATER HEATERS

STORM WINDOWS

TELEPHONES

TELEVISIONS

UNINTERRUPTIBLE POWER SUPPLIES

VENDING MACHINES

VENTILATION FANS

VOICE OVER INTERNET PROTOCOL (VOIP) PHONES

WATER COOLERS

WHOLE HOME TANKLESS GAS WATER HEATERS

Demand Hot Water Recirculating System

Cool Roofs

Rooftop Solar

Green Power Options

Programs and Strategies for Energy Access

Energy Efficiency Home Upgrade Assistance

Inclusive Utility Investment

Product Specifications & Partner Commitments Search

Products Tools and Resources

Recycle

Save on Heating Costs with ENERGY STAR This Season

Scoping Reports

Smart Home Tips for Saving Energy

DIY Lighting with ENERGY STAR

Eligible Commercial Fixture Types

Learn About Brightness

Learn About LED Lighting

Medical Imaging Equipment For Partners

Recent Program Updates

Save Energy in the Data Center / Server Room: Additional Resources

The Certified Lighting Subcomponent Database (CSD)

Earth Day 2023

Enjoy Spring Savings and Help the Planet

Keep Your Cool AND Save Your Money this Summer

Gifts that Do a World of Good

Most Efficient

Utilize Containment/Enclosures

Containment refers to physical barriers used in a hot aisle/cold aisle layout that further eliminate the mixing of cold ("supply") air and hot exhaust air.  Containment barriers include plastic curtains and Plexiglas sheets that prevent hot exhaust air from flowing over the tops of server racks, mixing with cold supply air, and thereby reducing its cooling capacity.

With containment in place, CRAC units can reduce their fan speeds, CRAH units can use higher temperature chilled water, and economizers can be utilized more often for “free cooling.”  Despite these energy-saving benefits, a 2014 Uptime Institute survey indicated that only 30% of operators have at least ¾ of their data center using some form of containment. Less than half of all survey respondents had at least 50% of their data center benefiting from containment.1

Hot Aisle / Cold Aisle Layout: Good, But You Can Do Better

The hot aisle/cold aisle layout helps prevent cold “supply” air from mixing with hot exhaust air, resulting in cooling savings from 10 to 35 percent.  While hot aisle/cold aisle layout is a sound start on the road to an energy-efficient data center, hot exhaust air can still flow over the top of servers, leading to higher server inlet temperatures at the upper portion of server racks.  (See Figure 1.)  Likewise, air from the cold aisle can “short circuit” by flowing around the sides or over the tops of racks to mix with hot return air.  Both of these scenarios result in energy waste because fans, CRACs and CRAHs must work harder to make up for higher temperatures in the cold aisle.

Data Center Diagram
Figure 1: Diagram of a hot aisle/cold aisle configuration without containment. Note the mixing of hot and cold air. (Image credit: 42U.com)

Containment Options

It’s Curtains for Google

“We’ve used effectively the kind of curtains you’d use in a meat locker in a grocery store to keep cold air from infiltrating with the hot air, and vice versa. The reason we’re using those is that we can put any rack in there we want. All we need to do is roll up the curtains, wheel in a rack and then drop the curtain down on top of the rack and it’s effectively sealed off. So there are very cheap solutions you can apply in virtually any data center that will greatly reduce if not eliminate the potential for the hot and cold air to mix.”

- Google Energy Czar Bill Weihl

A variety of different containment barriers can prevent the mixing of hot exhaust air with cold supply air:

  • Flexible strip curtains. Similar to plastic refrigeration sheets you might see at a supermarket, flexible strip curtains are an inexpensive option. They are easily installed with an aluminum track system that allows curtains to attach to drop ceilings and to the tops of racks (as shown in Figure 2). Google has successfully deployed these devices in its data centers (see inset).2
  • Rigid Containment. This configuration effectively turns either the cold aisle or the hot aisle into its own room by sealing the aisle with doors, sidewalls, and roofs (as shown in Figures 3 and 4). These are often used for racks with very high densities (and therefore high heat loads.)
  • Rigid Containment with Chimneys and an Overhead Return Plenum. Two chimneys of vertical ductwork direct hot exhaust air from the hot aisle up into the overhead return plenum, which is created by a drop ceiling. (See in Figure 5.) Hot air in the plenum returns to the CRAC intakes where it is cooled.
Cold aisle containment
Figure 2: Cold aisle containment with flexible strip curtains (Image credit: 42U.com)
Hot Aisle Diagram
Figure 3: Hot aisle rigid containment with in-row cooling. The in-row air conditioner captures the hot exhaust air from the rear of the equipment, conditions it, and returns it to the cold aisle. (Image credit: Episode Network)
Cold Aisle Diagram
Figure 4: Cold aisle containment with rigid enclosures prevents cold supply air from the CRAC units from mixing with hot exhaust air. (Image credit: Keyzone Computer Products, Ltd.)
Hot Aisle Raised Floor
Figure 5: Hot aisle rigid containment with chimneys and overhead plenum. (Image credit: Belden.com)

Saving and Costs

  • Cold aisle containment can be implemented easily and quickly, and can reduce cooling-related energy costs by as much as 30 percent.3  It typically and carries a payback time measured in a few weeks to a few months, depending on whether utility rebates are available to help offset project costs.
  • PG&E's experience with containment retrofits indicated that typical paybacks can be less than two years.4
  • Google’s Green Data Centers: Network POP Case Study (PDF, 4 MB) examines a small data center’s experience with vented tile optimization, temperature and humidity adjustments, cold aisle containment, and CRAC air return extensions.  Taken together, these measures showed a return on investment (ROI) in less than one year.
  • An analysis of hot aisle versus cold aisle containment revealed hot aisle containment can save 40% more than cold aisle containment5 for two main reasons.  One is that the higher return air temperatures produced by hot aisle containment allow cooling units to work more efficiently.  The second is that cold aisle containment can result in the uncontained area (where workers spend most their time) becoming too hot.  Uncomfortable working conditions force staff to increase the use of mechanical cooling.
  • Other potential costs for consideration include:
    • HVAC system adjustments/tuning after containment barriers are installed.  For example, CRAC unit operation can no longer be governed by return air temperatures -- they must use server inlet temperatures instead
    • Electrical costs for reconfiguring power distribution to the racks, and
    • Associated labor, overtime, and vendor costs, if applicable.

Tips and Considerations

Cold Rooms Help Control Energy Costs

At NetApp's Global Dynamic Laboratory, air containment plays an important role in saving energy. The data center includes tunnel-like enclosures, or cold rooms, that prevent hot exhaust air from mixing with cool supply air.

This design enables data center operators to use warmer supply air (70 to 80 degrees F vs. 50 to 60 degrees F).  Using warmer supply air reduces the runtime of the chilled water system because the facility can use ambient air more often. It also lowers overall fan horsepower by about 3 percent because warmer air is lighter and easier to move.

Another cost-saving aspect of the design involves locating two air handlers above each cold room. This placement takes advantage of the fact that cool air sinks without the use of a fan.  (A traditional raised floor environment requires extra fan energy to push cool air upward from the subflooring.)

Last but not least, the facility can use higher chilled water supply temperatures. Cooling water to 55 degrees F instead of 44 degrees F boosts efficiency by about 20 percent.

  • Depending on their location inside the data center, adjustments to fire detection and/or fire suppression systems may be necessary. Staff at Kaiser Permanente’s ENERGY STAR certified data center deployed special above-aisle cold aisle containment tiles that shrink and drop to the floor at high temperatures – avoiding the need for a fire suppression system.  See their case study (PDF, 79 KB) and public service announcement (PDF, 2 MB).
  • When the cold aisle is contained, the rest of the data center becomes warmer.  This may result in uncomfortable working conditions for staff and unsafe operating temperatures for some equipment.
  • Though many CRAC units use return air temperature to indicate room temperature, this will not work with containment because the return air is concentrated and therefore much hotter. (Return air refers to warm air entering the CRAC for cooling.)  Instead, CRAC unit operation should be governed by server inlet temperatures.
  • A paper by American Power Conversion (APC) (PDF, 657 KB) argued for hot aisle containment over cold aisle containment for three reasons:
    1. Air returning to the air conditioning unit is hotter, resulting in better cooling unit efficiency.
    2. Increased economizer mode hours.
    3. Server inlets have access to a large air mass (the rest of the data center room) that can help prevent overheating in case of a cooling failure.

1 https://journal.uptimeinstitute.com/2014-data-center-industry-survey/

2 Source: 2010 Green.net Conference

3 Focused Cooling Using Cold Aisle Containment, https://www.vertivco.com/globalassets/shared/focused-cooling-using-cold-aisle-contaiment.pdf (PDF, 582 KB)

4 Conversation with Mark Bramfitt, former Principal Program Manager, High Technology Energy Efficiency Team, PG&E, July 14, 2010.

5 Source: http://www.facilitiesnet.com/whitepapers/pdfs/APC_011112.pdf (PDF, 684 KB)

ENERGY STAR
United States Environmental Protection Agency

Save Energy.

  • Find Products
  • Save at Home
  • New Homes
  • Commercial Buildings
  • Industrial Plants
  • Partner Resources

Learn More.

  • About Us
  • Join
  • Newsroom
  • Privacy
  • Accessibility Statement
  • Help Desk

Stay Informed.

  • Public Notices
  • Consumer Newsletter
  • Program Updates
Back to top