Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

ENERGY STAR
Utility Navigation
  • About
  • For Partners
Main navigation
  • Find Products
    • Product Finder
    • Rebate Finder
    • Ask the Experts
    • Product Specification Search
    • Best Value Finder
    • Frequently Asked Questions
  • Save at Home
    • Heat & Cool Efficiently
    • Seal and Insulate
    • Expert Home Improvements
  • New Homes
    • Find a Builder
    • Homeowner Benefits
    • Join as a Partner
    • Program Requirements
    • Residential Resources
    • § 45L Builder Tax Credit
    • ENERGY STAR NextGen
    • About Us
  • Commercial Buildings
    • Benchmark
    • Save Energy
    • Earn Recognition
    • Resources by Audience
    • Resources by Topic
    • Training
    • About Us
  • Industrial Plants
    • Industrial Partnership
    • Industrial Assistance Network
    • Plant Certification
    • Challenge for Industry
    • Industries in Focus
    • Treasure Hunt
    • Get started with ENERGY STAR
    • Program Administrators
    • Service & Product Providers
    • Decarbonizing Industry
Breadcrumb
  1. Home
  2. Energy Efficient Products
  3. Data Center Equipment
  4. 16 More Ways To Cut Energy Waste In The Data Center
  5. Consider Water-Side Economizers

AIR CLEANERS

AIR-SOURCE HEAT PUMPS

AUDIO/VIDEO

BOILERS

CEILING FANS

CENTRAL AIR CONDITIONER

CLOTHES DRYERS

CLOTHES WASHERS

COMMERCIAL BOILERS

COMMERCIAL CLOTHES WASHERS

Commercial Food Service Equipment

COMMERCIAL WATER HEATERS

COMPUTERS

DECORATIVE LIGHT STRINGS

DEHUMIDIFIERS

DATA CENTER STORAGE

DATA CENTERS

DIGITAL MEDIA PLAYER

Data Center Equipment

  • Embedded Data Centers
  • 5 Simple Ways to Avoid Energy Waste in Your Data Center
  • 16 More Ways to Cut Energy Waste in the Data Center
    • Consolidate Lightly-utilized Servers
    • Implement Efficient Data Storage Measures
    • Utilize Built-in Server Power Management Features
    • Reduce Energy Losses from Power Distribution Units (PDUs)
    • Reduce Energy Loss from Uninterruptible Power Supply Systems
    • Manage Airflow for Cooling Efficiency
    • Move to a Hot Aisle/Cold Aisle Layout
    • Utilize Containment/Enclosures
    • Consider Water Side Economizers
    • Install In-rack or In-row Cooling
    • Make Humidification Adjustments
    • Use an Air-Side Economizer
    • Use Sensors and Controls - Match Cooling, Airflow, IT Loads
    • Provide Energy-efficiency Awareness Training
    • Select a Sustainable Colocation Facility
  • The Energy Cost of Cryptocurrency
  • Data Centers for Utilities
  • IT Solutions and Power Infrastructure
  • Optimize Airflow and HVAC

DUCTLESS HEATING & COOLING

ELECTRIC COOKING PRODUCTS

ELECTRIC VEHICLE CHARGERS

ENTERPRISE SERVERS

FREEZERS

FURNACES

GEOTHERMAL HEAT PUMPS

HEAT PUMP WATER HEATERS

HIGH EFFICIENCY GAS STORAGE WATER HEATERS

IMAGING EQUIPMENT

LABORATORY GRADE REFRIGERATORS AND FREEZERS

LARGE NETWORK EQUIPMENT

LIGHT COMMERCIAL HEATING & COOLING

LIGHT FIXTURES

MONITORS

POOL PUMPS

REFRIGERATORS

RESIDENTIAL WINDOWS, DOORS & SKYLIGHTS

ROOM AIR CONDITIONERS

Seal and Insulate with ENERGY STAR for Partners

SIGNAGE DISPLAYS

SMART HOME ENERGY MANAGEMENT SYSTEMS

SMART THERMOSTATS

SOLAR WATER HEATERS

STORM WINDOWS

TELEPHONES

TELEVISIONS

UNINTERRUPTIBLE POWER SUPPLIES

VENDING MACHINES

VENTILATION FANS

VOICE OVER INTERNET PROTOCOL (VOIP) PHONES

WATER COOLERS

WHOLE HOME TANKLESS GAS WATER HEATERS

Demand Hot Water Recirculating System

Cool Roofs

Rooftop Solar

Green Power Options

Programs and Strategies for Energy Access

Energy Efficiency Home Upgrade Assistance

Inclusive Utility Investment

Product Specifications & Partner Commitments Search

Products Tools and Resources

Recycle

Save on Heating Costs with ENERGY STAR This Season

Scoping Reports

Smart Home Tips for Saving Energy

DIY Lighting with ENERGY STAR

Eligible Commercial Fixture Types

Learn About Brightness

Learn About LED Lighting

Medical Imaging Equipment For Partners

Recent Program Updates

Save Energy in the Data Center / Server Room: Additional Resources

The Certified Lighting Subcomponent Database (CSD)

Earth Day 2023

Enjoy Spring Savings and Help the Planet

Keep Your Cool AND Save Your Money this Summer

Gifts that Do a World of Good

Most Efficient

Consider Water-Side Economizers

In a large data center, a mechanical chiller1 often provides a continuous supply of chilled water for use in air handling units2 to cool the data center. A water-cooled chiller uses a separate “condenser” water loop to take away the heat gained in the chiller’s refrigerant3 and release the heat in an evaporative cooling tower.4

Chiller-less Cooling

When it is cold and dry enough outside, the condenser water itself can be used to cool the chilled water directly through a separate heat exchanger (“water-side economizer”) and the chiller can be bypassed. Please see Figure 1 below with chilled water loop in dark blue and yellow and the condenser water loop in light blue and orange.  Water side economizers save enormous amounts of energy because they cool water without operating the mechanical chiller. That’s why data center operators may refer to the use of economizers as “free cooling.”

Water-Side Economizer
Figure 1: Diagram of typical waterside economizer.

Risk Reduction

Water-side economizers offer cooling redundancy because they can provide chilled water in the event that a mechanical chiller goes offline. This can reduce the risk of data center down time.

Savings and Costs

During water-side economizer operation, the cost of producing chilled water is reduced by up to 70%.5  A number of studies have indicated favorable paybacks on water side economizer retrofits.  For example:

  • A 2014 DOE study of three federal data centers and proposed efficiency measures concluded that investment in a water-side economizer retrofit pays back in 2.3 years.6 
  • Water-side economizer retrofit projects tend to offer better return on investment for larger data centers. A paper published by ASHRAE demonstrates this point.  It cites a one year payback for a water-side economizer retrofit project on a chiller plant serving a data center with a 2,000 ton cooling load.  A smaller data center with a 110 ton cooling load had a payback of 5 to 10 years.7
  • Wells Fargo built an economizer into its Minneapolis data center facility at a cost of about $1 million.  The bank envisions saving up to $450,000 annually on its energy costs, since the water-side economizer takes advantage of the cold seasonal temperatures in Minnesota.8

Water side economizer retrofits can sometimes be too costly. Two ENERGY STAR certified data centers — operated by BNY Mellon (PDF, 600 KB) and Target (PDF, 609 KB) — examined water-side economizers and found unfavorable paybacks.

Tips and Considerations

  • Water side economizers are best suited in climates where the wet bulb temperature is lower than 55°F for 3,000 hours or more.9 This describes the majority of the United States, barring some areas in the Southwest and portions of the Southeast. (See Figure 2 below.)

    Water-side Free Cooling Map
    Figure 2: Hours of ideal water-side economizer conditions in the United States. (Courtesy of DOE and The Green Grid)
  • Water-side economizers can be integrated with the chiller or non-integrated. Integrated water-side economizers are the better option because they can pre-cool water before it reaches the chiller. Non-integrated water-side economizers run in place of the chiller when conditions allow.10
  • Data centers that use containment, along with a cold aisle or hot aisle configuration, can use higher supply air temperatures. These higher temperatures can be maintained using a higher chilled water set point of 55°F or warmer. This higher chilled water temperature allows water-side economizers to be used more often, saving energy.
  • Adequate physical space is a major concern when considering water-side economization. Oracle attempted a retrofit and concluded that the additional parts–new "pipes, valves, and controls"–required physical space that existing facilities simply did not have available. In addition, they had concerns about cooling tower operation and performance at freezing ambient conditions, and about control issues with switching between condense mode and economizer chiller mode.  In the end, they settled on new variable speed chillers that were extremely efficient at low ambient outdoor temperatures.11
  • Water side economizers use a great deal of water in their evaporative cooling towers. Digital Realty recently deployed a new type of free-cooling system: one that uses pumped-refrigerant economization and consumes no water.12

1 A chiller is an industrial machine that removes heat from water via a refrigeration cycle to produce chilled water, typically at 35 to 45 degrees.

2 Air handling units typically use fans to blow unconditioned air across copper tubes that are filled with circulating chilled water.  This provides cool “supply” air to the data center.

3 The condenser water is used to cool the refrigerant and condense it from a gas to a liquid.

4 A cooling tower is a special type of heat exchanger that allows water and air to come in contact with each other in order to lower the temperature of the hot water. In a cooling tower, small volumes of water evaporate, lowering the temperature of the water circulating throughout the cooling tower.

5 Data Center Best Practice Guide, PG&E.  

6 Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers. DOE. May 2014. Available online at: http://energy.gov/sites/prod/files/2014/06/f16/casestudy_3federaldatacenters_0.pdf (PDF, 1.3 MB)

7Stein, Jeff.  Waterside Economizing in Data Centers: Design and Control Considerations (PDF, 397 KB). ASHRAE, 2009.

8 Mitchell, R. L. (2007, November 5). Case Study: Wells Fargo’s Free Data Center Cooling System. Retrieved February 10, 2009, from Computerworld.

9 Data Center Best Practice Guide, PG&E.  

10Stein, Jeff.  Waterside Economizing in Data Centers: Design and Control Considerations (PDF, 397 KB).  ASHRAE, 2009.

11  EPA Conference on Enterprise Servers and Data Centers: Opportunities for Energy Savings, January 31 to February 1, 2006.  Available online at: https://www.energystar.gov/sites/default/files/asset/document/MKhattar_Case_Study.pdf (PDF, 123 KB)

12 Case Study: Digital Realty Saves Water with Innovative Cooling Technology.  9/2/2016. Available online at: http://www.datacenterjournal.com/case-study-digital-realty-saves-water-innovative-cooling-technology/

ENERGY STAR
United States Environmental Protection Agency

Save Energy.

  • Find Products
  • Save at Home
  • New Homes
  • Commercial Buildings
  • Industrial Plants
  • Partner Resources

Learn More.

  • About Us
  • Join
  • Newsroom
  • Privacy
  • Accessibility Statement
  • Help Desk

Stay Informed.

  • Public Notices
  • Consumer Newsletter
  • Program Updates
Back to top