| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Televisions  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
|
| Application |
Indicate the application or market for which the product is intended for use. |
R |
Y |
Enumeration Data |
|
- Consumer
- Commercial Signage/Monitor
- Hospital Grade
- Hospitality
- Other
|
| Display Type |
|
R |
N |
Enumeration Data |
|
- DLP
- LCD
- OLED
- Plasma
- Other
|
| Other Display Type |
Required if the Display Type is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Backlight Technology |
|
R |
N |
Enumeration Data |
|
- CCFL
- Direct-lit LED
- Edge-lit LED
- HCFL
- LED edge-lit
- LED full-backlit
- OLED
- Other
|
| Other Backlight Technology |
Required if the Backlight Technology is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Native Vertical Resolution (lines) |
|
R |
N |
Integer |
|
|
| Native Horizontal Resolution (lines) |
|
R |
N |
Integer |
|
|
| Resolution Format |
|
R |
N |
Enumeration Data |
|
- 720p
- 1080i
- 1080p
- 2160p
- Other
|
| Other Resolution Format |
Required if the Resolution Format is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Local Dimming |
|
R |
N |
Enumeration Data |
|
- None
- Display Dims as an Entire Unit
- Display Dims by Horizontal or Vertical Rows
- Display Dims in Local Sectors
- Other
|
| Other Local Dimming |
Required if Local Dimming is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Viewable Screen Height (in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Viewable Screen Width (in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Diagonal Viewable Screen Size (in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Viewable Screen Area (sq in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| External Power Supply (EPS) |
Indicate whether the product ships with an External Power Supply (EPS). |
R |
N |
Enumeration Data |
|
|
| Features |
Indicate all available features in the product. The features should include those not enabled during tests for ENERGY STAR certification. |
R |
Y |
Enumeration Data |
|
- 3D
- Additional Analog Tuner
- Anti-Burn-In
- Anti-Glare
- Automatic Brightness Control
- Digital IP Tuner
- Electronic Program Guide
- Energy Gauge
- Gesture Recognition
- HPNA
- High Dynamic Range
- Integrated DVD
- Integrated DVR
- Integrated Hard Drive
- MoCA
- Motion Blur Reduction
- Occupancy Sensor
- Picture-in-Picture
- Quick Start
- Upconversion
- User Adjustable Backlight
- Voice Recognition
- Wide Color Gamut
- Other
- None
|
| Features Enabled in Default On Mode |
Indicate features enabled in the default tested On Mode. |
R |
Y |
Enumeration Data |
|
- Automatic Brightness Control
- Gesture Recognition
- High Dynamic Range
- Motion Blur Reduction
- Occupancy Sensor
- Upconversion
- Voice Recognition
- Other
- None
|
| Features Enabled in Default On Mode Other |
Required if Features Enabled in Default On Mode is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Features Enabled in Default Standby-Passive Mode |
Required for models tested in Standby-Passive Mode. Indicate the features enabled in the tested default Standby-Passive Mode. |
R |
Y |
Enumeration Data |
|
- Gesture Recognition
- Internal Timer or Clock
- Quick Start
- Occupancy Sensor
- Voice Recognition
- Other
- None
- N/A
|
| Features Enabled in Default Standby-Passive Mode Other |
Required if Features Enabled in Default Standby-Passive Mode is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Features Enabled in Default Standby-Active, Low Mode |
Required for models tested in Standby-Active, Low Mode. Indicate the features enabled in the tested default Standby-Active, Low Mode. |
R |
Y |
Enumeration Data |
|
- Gesture Recognition
- Internal Timer or Clock
- Quick Start
- Occupancy Sensor
- Voice Recognition
- Wake-on-LAN
- WoWLAN
- Other
- None
- N/A
|
| Features Enabled in Default Standby-Active, Low Mode Other |
Required if Features Enabled in Default Standby-Active, Low Mode is Other. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Full Network Connectivity |
Required for models tested in Standby-Active, Low Mode. Indicate whether the model meets the definition of Full Network Connectivity. |
O |
N |
Enumeration Data |
|
|
| Features Enabled in Default Standby-Active, High Mode |
Required for models with a Standby-Active, High Mode. Indicate the features enabled in the tested default Standby-Active, High Mode. |
R |
Y |
Enumeration Data |
|
- Gesture Recognition
- Internal Timer or Clock
- Quick Start
- Occupancy Sensor
- Voice Recognition
- Other
- None
- N/A
|
| Features Enabled in Default Standby-Active, High Mode Other |
Required if Features Enabled in Default Standby-Active, High Mode is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Wireless Technologies Supported |
Indicate the wireless band and frequency supported by the model. |
R |
Y |
Enumeration Data |
|
- IEEE 802.11ac, 5 GHz
- IEEE 802.11n, 5 GHz
- IEEE 802.11n, 2.4 GHz
- IEEE 802.11g, 2.4 GHz
- IEEE 802.11b, 2.4 GHz
- IEEE 802.11a, 5 GHz
- Other
- None
|
| Low Power Wireless Technologies |
Indicate whether the model supports low power wireless technologies. |
R |
Y |
Enumeration Data |
|
- ZigBee
- Bluetooth
- Other
- None
|
| Physical Data Ports |
|
R |
Y |
Enumeration Data |
|
- Universal Serial Bus (USB)
- Firewire
- Thunderbolt
- SATA
- SCSI
- RS-232
- Other
- None
|
| Ethernet Supported |
|
R |
Y |
Enumeration Data |
|
- Fast Ethernet (100 Mbit/s)
- Gigabit Ethernet (1000 Mbit/s)
- Fast Energy Efficient Ethernet (IEEE 802.3az)
- Gigabit Energy Efficient Ethernet (IEEE 802.3az)
- None
- Other
|
| Thin Client Capability |
Indicate whether the product has Thin Client Capability. |
R |
N |
Enumeration Data |
|
|
| Multimedia Protocols |
Indicate the interoperability protocols to receive and share multimedia supported by the model. |
R |
Y |
Enumeration Data |
|
|
| Multimedia Protocols Other |
Required if Multimedia Protocols is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Audio/Video Ports |
|
R |
Y |
Enumeration Data |
|
- Coaxial
- Component
- Composite
- DVI
- HDMI 2.X
- HDMI 1.X
- IEEE 1394
- RF
- S-Video
- VGA
- Other
|
| Other Audio/Video Ports |
Required if Audio/Video Ports is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| On Mode Power at 100 lx (W) |
Required for models with ABC enabled by default. Provide the measured On Mode Power at 100 lx illuminance. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| On Mode Power at 35 lx (W) |
Required for models with ABC enabled by default. Provide the measured On Mode Power at 35 lx illuminance. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| On Mode Power at 12 lx (W) |
Required for models with ABC enabled by default. Provide the measured On Mode Power at 12 lx illuminance. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| On Mode Power at 3 lx (W) |
Required for models with ABC enabled by default. Provide the measured On Mode Power at 3 lx illuminance. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| Measured On Mode Power (W) |
Provide the measured On Mode power (Pon) at 115 V. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Reported On Mode Power (W) |
Provide the rated/reported On Mode power at 115 V for models with or without ABC enabled by default, which will appear on the ENERGY STAR list of certified products. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Maximum On Mode Power for Certification (W) |
Provide the Maximum On Mode Power limit for the product plus high resolution allowance, if applicable. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Luminance in Default Picture Setting (cd/m^2) |
Provide the number in candelas per square meter. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Name of Default Picture Setting as Shipped |
Name of Default Picture Setting (or as selected using forced menu). |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Luminance in Brightest Selectable Picture Setting (cd/m^2) |
Provide the number in candelas per square meter. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Name of Brightest Selectable Preset Picture Setting |
Also known as the Brightest Selectable Picture Setting in the Final Rule. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Measured Standby-Passive Mode Power (W) |
Provide the measured Standby-Passive Mode power (Pstandby-passive) in watts. Provide power use at 115 V. |
R |
N |
Decimal |
No. of Decimal: 1
Max Value: 0.5
|
|
| Reported Standby-Passive Mode Power (W) |
Provide the rated/reported Standby-Passive Mode power in watts at 115 V, which will appear on the ENERGY STAR list of certified products. |
R |
N |
Decimal |
No. of Decimal: 1
Max Value: 0.5
|
|
| Measured Standby-Active, Low Mode Power (W) |
Required if Standby-Active mode included. Provide the measured Standby-Active, Low Mode power (Pstandby-active, low) in watts. Provide power use at 115 V. |
O |
N |
Decimal |
No. of Decimal: 1
Max Value: 3.0
|
|
| Reported Standby-Active, Low Mode Power (W) |
Required if Standby-Active mode included. Provide the rated/reported Standby-Active, Low Mode power in watts at 115 V, which will appear on the ENERGY STAR list of certified products. |
O |
N |
Decimal |
No. of Decimal: 1
Max Value: 3.0
|
|
| Reported Annual Energy Consumption (kWh) |
Provide the rated/reported Annual Energy Consumption power in kWh at 115 V, which will appear on the ENERGY STAR list of certified products. Values less than 100 kWh shall be rounded to the nearest tenth of a kWh; otherwise, they shall be rounded to the nearest kWh, as specified in Section 8.2 of Appendix H to 10 CFR Part 430. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Download Acquisition Mode (DAM) Present |
Indicate whether the product has a Download Acquisition Mode. |
R |
N |
Enumeration Data |
|
|
| DAM Duration (min per day) |
Required if Download Acquisition Mode (DAM) Present is Yes. Indicate typical time in DAM. If typical time in DAM is less than a minute, indicate number of seconds in decimal form i.e. 0.75 for 45 seconds. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| DAM Measured Power (W) |
Required if Download Acquisition Mode (DAM) Present is Yes. Indicate typical power consumed while in DAM. Provide power use at 115 V. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| DAM Functions |
Required if Download Acquisition Mode (DAM) Present is Yes. Indicate which activities occur under DAM. |
O |
Y |
Enumeration Data |
|
- Download Channel Listing Information for Use by an Electronic Programming Guide
- Monitor for Emergency Messaging/Communications
- Otherwise Communicate Through a Network Protocol
- Other
- N/A
|
| Second Prompt Confirming Retail Configuration |
Indicate whether the product displays a second prompt confirming selection of Retail Configuration. |
R |
N |
Enumeration Data |
|
|
| Information Displayed About Default Picture Setting |
Indicate Yes if model displays information that Default Picture Setting is setting under which product is certified for ENERGY STAR. Settings other than the default setting (the default setting may be called “Home” or “Auto” or “General”), can include other pre-set picture settings such as “Sports,” “Cinema,” etc. Products with a physical ENERGY STAR mark affixed to the front or top of the TV may display alternate language. |
R |
N |
Enumeration Data |
|
- Yes
- No
- No Other Picture Settings Available
|