| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Directional_Lamps_1_x  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Lamp Category |
Indicate if the model is omnidirectional, directional, or decorative. |
R |
N |
Enumeration Data |
|
|
| Technology Used |
Indicate if the model utilizes CFL or LED to generate the light. |
R |
N |
Enumeration Data |
|
|
| Certification Status |
Indicate whether the light source has achieved initial certification or full certification. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Full Certification
|
| Base Type |
Indicate one of the allowable base types. |
R |
N |
Enumeration Data |
|
- E26
- E26d
- E17
- E11
- E12
- GU10
- GU24
- GU5.3
- GX5.3
|
| Tested Voltage (V) |
Provide the voltage at which the model was tested. |
R |
N |
Enumeration Data |
|
- 12 AC
- 12 DC
- 24 AC
- 24 DC
- 120
- 240
- 277
|
| Reported Voltage (V) |
Provide the rated/reported voltage(s). |
R |
Y |
Enumeration Data |
|
- 12 AC
- 12 DC
- 24 AC
- 24 DC
- 120
- 240
- 277
|
| Multiple Discrete Light Output Levels |
Indicate if the model has multiple distinct light output levels (e.g. 3-way). For multiple output lamps, provide performance information at the highest output level throughout the template. |
R |
N |
Enumeration Data |
|
|
| Measured Input Power (W) |
Provide the measured input power of the model based on test data. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
|
|
| Reported Input Power (W) |
Provide the rated/reported lamp input power of the model, which will appear on the list of ENERGY STAR certified products. This value is required to be the same as measured or more conservative (more consumptive) as permitted for the purposes of safety ratings. Note that reported light output divided by reported wattage must meet the specification requirements for efficacy. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
|
|
| Claimed Wattage Equivalency |
Required if the model makes wattage equivalency claims to a standard incandescent. |
O |
N |
Integer |
Min Value: 0
|
|
| Lamp Shape Equivalency |
Provide the lamp shape that the manufacturer is claiming equivalency to. |
R |
N |
Enumeration Data |
|
- ER30
- ER40
- R14
- R16
- R20
- R30
- R40
- BR30
- BR38
- BR40
- PAR14
- PAR16
- PAR20
- PAR30
- PAR30L
- PAR38
- MR16
- MRX16
- CFL Reflector
|
| Maximum Overall Length (mm) |
Provide the maximum overall length of the model tested in millimeters. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
|
|
| Maximum Overall Diameter (mm) |
Provide the maximum overall diameter of the model tested in millimeters. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
|
|
| Center Beam Intensity (cd) |
Required for PAR and MR lamps. Provide the peak center beam candle power in candela. |
O |
N |
Integer |
Min Value: 0
|
|
| Frequency (Hz) |
Provide the average frequency based on test data. |
R |
N |
Integer |
Min Value: 120
|
|
| Start Time (ms) |
Provide the average start time, in milliseconds, based on test data. |
R |
N |
Integer |
Max Value: 1000
|
|
| CFL: Covered/Bare Tube |
Required for CFL lamps. Indicate whether the lamp has an envelope over the light source or not. |
O |
N |
Enumeration Data |
|
|
| CFL: Mercury Content (mg) |
Required for CFL lamps. Provide the manufacturer's claimed mercury content in mg of mercury in the tested model. |
O |
N |
Decimal |
No. of Decimal: 1
Max Value: 3.0
|
|
| CFL: Run-Up Time to 80% (s) |
Required for CFL lamps. Provide the average measured run-up time, in seconds, of the model based on test data. |
O |
N |
Integer |
Max Value: 120
|
|
| Measured Efficacy (lm/W) |
Provide the calculated value based on test data per supplemental testing guidance in section 9.1. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 40.0
|
|
| Reported Efficacy (lm/W) |
Provide the calculated value based on reported light output and reported input power. Note that reported light output divided by reported wattage must meet the specification requirements for efficacy. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 40.0
|
|
| Measured Light Output (lm) |
Provide the measured light output of the model based on test data. |
R |
N |
Integer |
|
|
| Tolerance Applied to Light Output |
Indicate if a 3% tolerance has been applied to the measured light output. |
R |
N |
Enumeration Data |
|
|
| Reported Light Output (lm) |
Required for all lamps except MR and PAR. Reported light output per section 9.2 should be consistent with the value stated on the product packaging and will appear on the list of ENERGY STAR certified products. Values may be more conservative. Note that reported output divided by reported wattage must meet the specification requirements for efficacy. |
O |
N |
Integer |
Min Value: 0
Max Value: 6000
|
|
| Elevated Temperature Light Output Ratio |
Required for directional lamps that do not restrict use in enclosed or recessed fixtures. Indicate the percentage in decimal format. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.90
|
|
| Rated Life (Hours) |
Provide claimed lifetime, in hours, supported by lumen maintenance and life testing. |
R |
N |
Integer |
Min Value: 10000
|
|
| Nominal Correlated Color Temperature (CCT) |
Provide the nominal CCT which will appear on the list of ENERGY STAR certified products. |
R |
N |
Enumeration Data |
|
- 2700K
- 3000K
- 3500K
- 4000/4100K
- 5000K
- 6500K
|
| Correlated Color Temperature (CCT) |
Provide the average CCT value based on test data. |
R |
N |
Integer |
Min Value: 2580
Max Value: 7040
|
|
| Color Rendering Index (CRI) |
Provide the average CRI value based on test data. |
R |
N |
Integer |
Min Value: 80
Max Value: 100
|
|
| CRI: Average R9 |
Provide the average R9 of the samples based on test data. |
R |
N |
Integer |
|
|
| LED: Color Maintenance |
Required for solid state lamps. Provide the average change in chromaticity between 0 and 6,000 hours. |
O |
N |
Decimal |
No. of Decimal: 3
Max Value: 0.007
|
|
| LED: Color Angular Uniformity |
Required for directional solid state lamps. Indicate the variation of chromaticity across the beam angle of the lamp. |
O |
N |
Decimal |
No. of Decimal: 3
Max Value: 0.006
|
|
| LED: Lumen Maintenance at 3,000 Hours |
Required for solid state lamps that utilize the early interim certification option. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%) without adding tolerance. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.931
|
|
| LED: Lumen Maintenance at 6,000 Hours |
Required for solid state lamps. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%) without adding tolerance. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.867
|
|
| LED: Lumen Maintenance at 7,500 Hours |
Required for solid state lamps that have tested to or past 7,500 hours. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.915
|
|
| LED: Lumen Maintenance at 8,750 Hours |
Required for solid state lamps that have tested to or past 8,750 hours. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.915
|
|
| LED: Lumen Maintenance at 10,000 Hours |
Required for solid state lamps that have tested to or past 10,000 hours. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.915
|
|
| LED: Lumen Maintenance at 11,250 Hours |
Required for solid state lamps that have tested to or past 11,250 hours. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.915
|
|
| LED: Lumen Maintenance at 12,500 |
Required for solid state lamps that have tested to or past 12,500 hours. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .95 for 95%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.915
|
|
| CFL: Lumen Maintenance at 1,000 Hours |
Required for CFL lamps. Indicate the lumen maintenance value as a percentage in decimal format (i.e., us .85 for 85%). |
O |
N |
Decimal |
Min Value: 0.900
|
|
| CFL: Lumen Maintenance at 40% of Rated Life |
Required for CFL lamps. Indicate the lumen maintenance value as a percentage in decimal format (i.e., use .85 for 85%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.800
|
|
| CFL: United Surviving at Rated Life |
Required for CFL lamps. Indicate the percentage of units, in decimal format, surviving life testing at rated life. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.50
|
|
| RCST: Number of Cycles |
Provide the number of cycles surviving rapid cycle stress testing. |
R |
N |
Integer |
Min Value: 5000
|
|
| Measured Beam Angle (degrees) |
Required for directional lamps. Provide the measured beam angle in degrees based on test data. |
O |
N |
Integer |
Max Value: 360
|
|
| Reported Beam Angle (degrees) |
Required for directional lamps. Provide the reported beam angle in degrees. |
O |
N |
Integer |
Max Value: 360
|
|
| Power Factor |
Required for all lamps except lamps less than or equal to 5 watts. Provide the average power factor based on test data. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| Minimum Starting or Operating Temperature (C) |
Provide the minimum starting or operating temperature for the model tested. |
R |
N |
Integer |
|
|
| Dimmable |
Indicate whether the model is dimmable or non-dimmable. |
R |
N |
Enumeration Data |
|
|
| Dimming: Claimed Minimum Light Output Level |
Required for models claiming dimming capability. Indicate the manufacturer reported minimum light output level as a percentage, in decimal format (i.e., use .85 for 85%). |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Dimmer Compatibility |
Required for models claiming dimming capability. Indicate the type of dimmer used to determine compatibility. |
O |
N |
Enumeration Data |
|
- Phase Cut
- Non Phase Cut
- NEMA SSL7
|
| Warranty (Years) |
|
R |
N |
Integer |
Min Value: 2
|
|
| Lamp Rated Applications |
Indicate if the model is rated for use by the manufacturer. Safety related fields must be consistent with lamp marking. |
R |
Y |
Enumeration Data |
|
- Enclosed Fixtures
- Not for Use in Enclosed Fixtures
- Recessed Fixtures
- Not for Use in Recessed Fixtures
- Damp Location Rated
- Wet Location Rated
- Use With Photo And/Or Motion Sensors
- Use With Timers
- Vibration Service
- Shatter Resistant
- Wireless Control
- Capable of Changing CCT
- Audio Capabilities
- None
- Other
|
| Lamp Rated Applications Other |
Required if Lamp Rated Application is Other. Provide the lamp rated application(s). |
O |
N |
Text |
Max Length: 1000
|
|
| Lamp Test Orientation |
Indicate if the model is listed as position restricted by the manufacturer. |
R |
N |
Enumeration Data |
|
- Universal - Not Position Restricted
- Vertical - Base Up Only
- Vertical - Base Down Only
- Horizontal Only
|
| Commercial/Residential |
Indicate if the model is intended to be sold for commercial applications, residential applications, or both. |
R |
Y |
Enumeration Data |
|
|
| Additional Notes |
Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model's listing such as 3-way light levels, etc). |
O |
N |
Text |
Max Length: 1000
|
|