Description: Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Computers Version 6.0. This template is for thin clients. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History Subscribe to updates via RSS 2.0:
  • 08/27/14 - Submit_Computers_Thin_Clients_6_x Updated
  • 12/16/13 - Submit_Computers_Thin_Clients_6_x Final
  • 11/26/13 - Submit_Computers_Thin_Clients_6_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Product Specific Information info
ENERGY STAR Specification Version R N Enumeration Data
  • 6.0
  • 6.1
Product Type R N Enumeration Data
  • Thin Client
  • Integrated Thin Client
System Sleep Mode Default Time Upon Shipment (min) Required if Sleep Mode default time upon shipment is applicable. O N Integer Max Value: 30
Display Sleep Mode Default Time Upon Shipment (min) Required if display sleep mode default time upon shipment is applicable. O N Integer Max Value: 15
Ethernet Capability R N Enumeration Data
  • Yes
  • No
Reduced Sleep/Off Ethernet Speed Required if Ethernet Capability is Yes. Indicate Yes if the speed of any active 1 Gb/s or higher Ethernet network links will be reduced to less than 1 Gb/s when transitioning to sleep or off mode. O N Enumeration Data
  • Yes
  • No
Product Sold Through Enterprise Channels R N Enumeration Data
  • Yes
  • No
Meets Wake Management Requirement R N Enumeration Data
  • Yes
  • No
  • Not Applicable
WOL (Wake on LAN) From Sleep Required if Ethernet Capability is Yes. O N Enumeration Data
  • Shipped Enabled Under All Conditions
  • Shipped Enabled When Operating on Ac Power Only
  • Shipped Disabled
  • Shipped Disabled with Both Client OS and Network Controls to Enable Feature
Has the Ability to Enable and Disable WOL for Sleep Mode Required if Ethernet Capability is Yes. O N Enumeration Data
  • Yes
  • No
Software Updates Indicate Yes if software updates are conducted from the centrally managed network while model is in Sleep or Off mode. R N Enumeration Data
  • Yes
  • No
Product Capable of Sleep R N Enumeration Data
  • Yes
  • No
Multimedia Encode/Decode Support R N Enumeration Data
  • Yes
  • No
Graphics Allowance Indicate if graphics adder is applicable. R N Enumeration Data
  • Yes
  • No
WOL Allowance Indicate if Wake on LAN adder is applicable. R N Enumeration Data
  • Yes
  • No
Operating System Name R Y Enumeration Data
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Operating System Name Other Required if Operating System Name is Other. O N Text Max Length: 1000
Processor Brand R N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Processor Name R Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Processor Name Other Required if Processor Name is Other. O N Text Max Length: 1000
Installed System Memory RAM (GB) Provide the memory actually installed in the model tested, not the maximum supported. R N Decimal No. of Decimal: 1
Min Value: 0.0
Graphics Category Required if graphics adder is applicable. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Switchable Graphics Enabled by Default in Ac Mode Required when a device has both integrated graphics and switchable graphics. This setting means that the graphics is switched to integrated graphics when the graphics demand is low. The OEM can provide guidance on detecting what state the graphics is in. This setting is only applicable when a device has both integrated graphics and discrete graphics. O N Enumeration Data
  • Yes
  • No
Discrete Graphics Frame Buffer Bandwidth (GB/s) Required if graphics adder is applicable. O N Decimal No. of Decimal: 1
Discrete Graphics Frame Buffer Data Width (bits) Required if graphics adder is applicable. O N Integer
Gigabit Ethernet Ports (count) R N Integer Min Value: 0
Energy Efficient Ethernet (EEE) Indicate if Energy Efficient Ethernet is supported. R N Enumeration Data
  • Yes
  • No
Number of Storage Drives R N Integer Min Value: 0
Number of Integrated Displays (count) Required if integrated display allowance is applicable. O N Integer
Integrated Display Resolution (megapixels) Required if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Integrated Display Viewable Screen Area (sq in) Required if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Enhanced Performance Display Present Required if Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Internal/External Pwr Supply Efficiency at 10% Load Required if available. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Internal Power Supply Efficiency at 20% Load Required if internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Internal Power Supply Efficiency at 50% Load Required if internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Internal Power Supply Efficiency at 100% Load Required if internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
External Power Supply Average Efficiency Required if available. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
External/Internal Power Supply Rated Power (W) Required if available. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Physical CPU Cores (count) Provide the number of physical - not logical - CPU cores. R N Integer Min Value: 0
CPU Packages (count) Provide the number of CPUs/packages. R N Integer Min Value: 0
CPU Base Clock Speed (GHz) Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. R N Decimal No. of Decimal: 1
Min Value: 0.0
CPU Maximum Clock Speed (GHz) Provide the burst, turbo, maximum, temporary, or intermittent clock speed. R N Decimal No. of Decimal: 1
Min Value: 0.0
Storage Technology Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. R Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Storage Technology Other Required if Storage Technology is Other. O N Text Max Length: 1000
Performance Score Performance Score is the product of Physical CPU Cores and CPU Clock Speed in GHz. R N Decimal No. of Decimal: 1
Min Value: 0.0
Proxy Support This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. R N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Measured Power in Off at 115 V (W) Required for models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Measured Power in Off at 230 V (W) Required for models tested at 230 V. O N Decimal No. of Decimal: 1
User-activated Low-power Mode Enabled by Default Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. R N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
User-activated Low-power Mode Enabled by Dflt Other Required if User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Long Idle State Pwr Used in Place of Sleep Mode Pwr Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). R N Enumeration Data
  • Yes
  • No
Measured Power in Sleep at 115 V (W) Required for models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Measured Power in Sleep at 230 V (W) Required for models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Measured Power in Long Idle at 115 V (W) Required for models tested at 115 V. O N Decimal No. of Decimal: 1
Measured Power in Long Idle at 230 V (W) Required for models tested at 230 V. O N Decimal No. of Decimal: 1
Measured Power in Short Idle at 115 V (W) Required for models tested at 115 V. O N Decimal No. of Decimal: 1
Measured Power in Short Idle at 230 V (W) Required for models tested at 230 V. O N Decimal No. of Decimal: 1
Reported TEC at 115 V (kWh) Required for models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported TEC at 230 V (kWh) Required for models tested at 230 V. O N Decimal No. of Decimal: 1
Maximum TEC Requirement (Etec max) (kWh) R N Decimal No. of Decimal: 1

Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Computers Version 6.0. This template is for thin clients. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.