Home > Partner Resources > Third-Party Certification > Certification Body Resources > XML Web Services Submission Process > ENERGY STAR Comp Desk, Note, IC, Port All-in-one, Slate/Tablets Template

ENERGY STAR Comp Desk, Note, IC, Port All-in-one, Slate/Tablets Template

Service Method: Submit_Computers_Desktops_Notebooks_and_Integrated_Desktops_6_x
Version Number: V6 Desktops, Notebooks, Integrated Desktops
Description: Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Computers Version 6.0 or Version 6.1. This template is for desktops, notebooks, integrated desktop computers, slates/tablets, two-in-one notebooks, and portable all-in-one computers. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History Subscribe to updates via RSS 2.0:
  • 08/27/14 - Submit_Computers_Desktops_Notebooks_and_Integrated_Desktops_6_x Updated
  • 12/16/13 - Submit_Computers_Desktops_Notebooks_and_Integrated_Desktops_6_x Final
  • 11/26/13 - Submit_Computers_Desktops_Notebooks_and_Integrated_Desktops_6_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Computers_Desktops_Notebooks_and_Integrated_Desktops info
ENERGY STAR Specification Version R N Enumeration Data
  • 6.0
  • 6.1
Product Type R N Enumeration Data
  • Desktop
  • Notebook
  • Integrated Desktop
  • Slate/Tablet
  • Two-In-One Notebook
  • Portable All-In-One Computer
System Sleep Mode Default Time Upon Shipment (min) Required if Sleep Mode default time upon shipment is applicable. O N Integer Max Value: 30
Display Sleep Mode Default Time Upon Shipment (min) Required if display sleep mode default time upon shipment is applicable. O N Integer Max Value: 15
Product Marketed as a Workstation R N Enumeration Data
  • Yes
  • No
Ethernet Capability R N Enumeration Data
  • Yes
  • No
Reduced Sleep/Off Ethernet Speed Required if Ethernet Capability is Yes. Indicate Yes if the speed of any active 1 Gb/s or higher Ethernet network links will be reduced to less than 1 Gb/s when transitioning to sleep or off mode. O N Enumeration Data
  • Yes
  • No
Product Sold Through Enterprise Channels R N Enumeration Data
  • Yes
  • No
Meets Wake Management Requirement R N Enumeration Data
  • Yes
  • No
  • Not Applicable
WOL (Wake on LAN) From Sleep Required if Ethernet Capability is Yes. O N Enumeration Data
  • Shipped Enabled Under All Conditions
  • Shipped Enabled When Operating on Ac Power Only
  • Shipped Disabled
  • Shipped Disabled with Both Client OS and Network Controls to Enable Feature
Has the Ability to Enable and Disable WOL for Sleep Mode Required if Ethernet Capability is Yes. O N Enumeration Data
  • Yes
  • No
Applicable Categories for TEC Criteria R Y Enumeration Data
  • 0
  • I1
  • I2
  • I3
  • D1
  • D2
Category 0 Operating System Name Required for Category 0 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category 0 Operating System Name Other Required for Category 0 models if Operating System Name is Other. O N Text Max Length: 1000
Category 0 Processor Brand Required for Category 0 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category 0 Processor Name Required for Category 0 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category 0 Processor Name Other Required for Category 0 models if Category 0 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category 0 Installed System Memory RAM (GB) Required for Category 0 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category 0 Graphics Category Required for Category 0 models if graphics adder is applicable, when a device has switchable graphics. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category 0 Switchable Graphics Enabled by Default in Ac Mode Required for Category 0 when a device has both integrated graphics and discrete graphics. This setting means that the graphics is switched to integrated graphics when the graphics demand is low. The OEM can provide guidance on detecting what state the graphics is in. This setting is only applicable when a device has both integrated graphics and discrete graphics. O N Enumeration Data
  • Yes
  • No
Category 0 Capable of Switchable Graphics in Battery Mode Required for Category 0 models when a device has switchable graphics. O N Enumeration Data
  • Yes
  • No
Category 0 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category 0 models when a device has discrete graphics. O N Decimal No. of Decimal: 1
Category 0 Discrete Graphics Frame Buffer Data Width (bits) Required for Category 0 models when a device has discrete graphics. O N Integer
Category 0 Gigabit Ethernet Ports (count) Required for Category 0 models. O N Integer Min Value: 0
Category 0 Energy Efficient Ethernet (EEE) Required for Category 0 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category 0 Number of Storage Drives Required for Category 0 models. O N Integer Min Value: 0
Category 0 Number of Integrated Displays (count) Required for Category 0 if integrated display allowance is applicable. O N Integer
Category 0 Integrated Display Resolution (megapixels) Required for Category 0 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category 0 Integrated Display Viewable Screen Area (sq in) Required for Category 0 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category 0 Enhanced Performance Display Present Required if for Category 0 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category 0 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category 0 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category 0 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category 0 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category 0 Internal Power Supply Efficiency at 20% Load Required if for Category 0 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category 0 Internal Power Supply Efficiency at 50% Load Required if for Category 0 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category 0 Internal Power Supply Efficiency at 100% Load Required if for Category 0 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category 0 External Power Supply Average Efficiency Required if for Category 0 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category 0 External/Internal Power Supply Rated Power (W) Required for Category 0 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category 0 Physical CPU Cores (count) Required for Category 0 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category 0 CPU Packages (count) Required for Category 0 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category 0 CPU Base Clock Speed (GHz) Required for Category 0 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category 0 CPU Maximum Clock Speed (GHz) Required for Category 0 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category 0 Storage Technology Required for Category 0 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category 0 Storage Technology Other Required if Category 0 Storage Technology is Other. O N Text Max Length: 1000
Category 0 Performance Score Required for Category 0 models. Performance Score is the product of Category 0 Physical CPU Cores and Category 0 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category 0 Proxy Support Required for Category 0 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category 0 Measured Power in Off at 115 V (W) Required for Category 0 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category 0 Measured Power in Off at 230 V (W) Required for Category 0 models tested at 230 V. O N Decimal No. of Decimal: 1
Category 0 User-activated Low-power Mode Enabled by Default Required for Category 0 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category 0 User-activated Low-power Mode Enabled by Dflt Other Required if Category 0 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category 0 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category 0 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category 0 Measured Power in Sleep at 115 V (W) Required for Category 0 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category 0 Measured Power in Sleep at 230 V (W) Required for Category 0 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category 0 Measured Power in Long Idle at 115 V (W) Required for Category 0 models tested at 115 V. O N Decimal No. of Decimal: 1
Category 0 Measured Power in Long Idle at 230 V (W) Required for Category 0 models tested at 230 V. O N Decimal No. of Decimal: 1
Category 0 Measured Power in Short Idle at 115 V (W) Required for Category 0 models tested at 115 V. O N Decimal No. of Decimal: 1
Category 0 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category 0 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Category 0 Measured Power in Short Idle at 230 V (W) Required for Category 0 models tested at 230 V. O N Decimal No. of Decimal: 1
Category 0 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category 0 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category 0 TEC at 115 V (kWh) Required for Category 0 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category 0 TEC at 230 V (kWh) Required for Category 0 models tested at 230 V. O N Decimal No. of Decimal: 1
Category 0 Base TEC Allowance Required for Category 0 models. O N Integer Min Value: 14
Max Value: 135
Category 0 Functional Adder Allowances (kWh) Required for Category 0 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category 0 Maximum TEC Requirement (Etec max) (kWh) Required for Category 0 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1
Category I1 Operating System Name Required for Category I1 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category I1 Operating System Name Other Required for Category I1 models if Operating System Name is Other. O N Text Max Length: 1000
Category I1 Processor Brand Required for Category I1 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category I1 Processor Name Required for Category I1 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category I1 Processor Name Other Required for Category I1 models if Category I1 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category I1 Installed System Memory RAM (GB) Required for Category I1 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I1 Graphics Category Required for Category I1 models if graphics adder is applicable, when a device has switchable graphics. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category I1 Switchable Graphics Enabled by Default in Ac Mode Required for Category I1 when a device has both integrated graphics and discrete graphics. This setting means that the graphics is switched to integrated graphics when the graphics demand is low. The OEM can provide guidance on detecting what state the graphics is in. This setting is only applicable when a device has both integrated graphics and discrete graphics. O N Enumeration Data
  • Yes
  • No
Category I1 Capable of Switchable Graphics in Battery Mode Required for Category I1 models when a device has switchable graphics. O N Enumeration Data
  • Yes
  • No
Category I1 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category I1 models when a device has switchable graphics. O N Decimal No. of Decimal: 1
Category I1 Discrete Graphics Frame Buffer Data Width (bits) Required for Category I1 models when a device has switchable graphics. O N Integer
Category I1 Gigabit Ethernet Ports (count) Required for Category I1 models. O N Integer Min Value: 0
Category I1 Energy Efficient Ethernet (EEE) Required for Category I1 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category I1 Number of Storage Drives Required for Category I1 models. O N Integer Min Value: 0
Category I1 Number of Integrated Displays (count) Required for Category I1 if integrated display allowance is applicable. O N Integer
Category I1 Integrated Display Resolution (megapixels) Required for Category I1 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I1 Integrated Display Viewable Screen Area (sq in) Required for Category I1 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I1 Enhanced Performance Display Present Required if for Category I1 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category I1 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category I1 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I1 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category I1 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I1 Internal Power Supply Efficiency at 20% Load Required if for Category I1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I1 Internal Power Supply Efficiency at 50% Load Required if for Category I1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I1 Internal Power Supply Efficiency at 100% Load Required if for Category I1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I1 External Power Supply Average Efficiency Required if for Category I1 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I1 External/Internal Power Supply Rated Power (W) Required for Category I1 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category I1 Physical CPU Cores (count) Required for Category I1 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category I1 CPU Packages (count) Required for Category I1 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category I1 CPU Base Clock Speed (GHz) Required for Category I1 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I1 CPU Maximum Clock Speed (GHz) Required for Category I1 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I1 Storage Technology Required for Category I1 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category I1 Storage Technology Other Required if Category I1 Storage Technology is Other. O N Text Max Length: 1000
Category I1 Performance Score Required for Category I1 models. Performance Score is the product of Category I1 Physical CPU Cores and Category I1 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I1 Proxy Support Required for Category I1 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category I1 Measured Power in Off at 115 V (W) Required for Category I1 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I1 Measured Power in Off at 230 V (W) Required for Category I1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I1 User-activated Low-power Mode Enabled by Default Required for Category I1 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category I1 User-activated Low-power Mode Enabled by Dflt Other Required if Category I1 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category I1 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category I1 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category I1 Measured Power in Sleep at 115 V (W) Required for Category I1 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I1 Measured Power in Sleep at 230 V (W) Required for Category I1 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I1 Measured Power in Long Idle at 115 V (W) Required for Category I1 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I1 Measured Power in Long Idle at 230 V (W) Required for Category I1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I1 Measured Power in Short Idle at 115 V (W) Required for Category I1 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I1 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I1 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Category I1 Measured Power in Short Idle at 230 V (W) Required for Category I1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I1 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I1 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category I1 TEC at 115 V (kWh) Required for Category I1 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category I1 TEC at 230 V (kWh) Required for Category I1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I1 Base TEC Allowance Required for Category I1 models. O N Integer Min Value: 14
Max Value: 135
Category I1 Functional Adder Allowances (kWh) Required for Category I1 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category I1 Maximum TEC Requirement (Etec max) (kWh) Required for Category I1 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1
Category I2 Operating System Name Required for Category I2 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category I2 Operating System Name Other Required for Category I2 models if Operating System Name is Other. O N Text Max Length: 1000
Category I2 Processor Brand Required for Category I2 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category I2 Processor Name Required for Category I2 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category I2 Processor Name Other Required for Category I2 models if Category I2 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category I2 Installed System Memory RAM (GB) Required for Category I2 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I2 Graphics Category Required for Category I2 models if graphics adder is applicable, when a device has switchable graphics. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category I2 Switchable Graphics Enabled by Default in Ac Mode Required for Category I2 when a device has both integrated graphics and discrete graphics. This setting means that the graphics is switched to integrated graphics when the graphics demand is low. The OEM can provide guidance on detecting what state the graphics is in. This setting is only applicable when a device has both integrated graphics and discrete graphics. O N Enumeration Data
  • Yes
  • No
Category I2 Capable of Switchable Graphics in Battery Mode Required for Category I2 models when a device has switchable graphics. O N Enumeration Data
  • Yes
  • No
Category I2 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category I2 models when a device has switchable graphics. O N Decimal No. of Decimal: 1
Category I2 Discrete Graphics Frame Buffer Data Width (bits) Required for Category I2 models when a device has switchable graphics. O N Integer
Category I2 Gigabit Ethernet Ports (count) Required for Category I2 models. O N Integer Min Value: 0
Category I2 Energy Efficient Ethernet (EEE) Required for Category I2 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category I2 Number of Storage Drives Required for Category I2 models. O N Integer Min Value: 0
Category I2 Number of Integrated Displays (count) Required for Category I2 if integrated display allowance is applicable. O N Integer
Category I2 Integrated Display Resolution (megapixels) Required for Category I2 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I2 Integrated Display Viewable Screen Area (sq in) Required for Category I2 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I2 Enhanced Performance Display Present Required if for Category I2 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category I2 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category I2 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I2 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category I2 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I2 Internal Power Supply Efficiency at 20% Load Required if for Category I2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I2 Internal Power Supply Efficiency at 50% Load Required if for Category I2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I2 Internal Power Supply Efficiency at 100% Load Required if for Category I2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I2 External Power Supply Average Efficiency Required if for Category I2 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I2 External/Internal Power Supply Rated Power (W) Required for Category I2 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category I2 Physical CPU Cores (count) Required for Category I2 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category I2 CPU Packages (count) Required for Category I2 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category I2 CPU Base Clock Speed (GHz) Required for Category I2 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I2 CPU Maximum Clock Speed (GHz) Required for Category I2 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I2 Storage Technology Required for Category I2 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category I2 Storage Technology Other Required if Category I2 Storage Technology is Other. O N Text Max Length: 1000
Category I2 Performance Score Required for Category I2 models. Performance Score is the product of Category I2 Physical CPU Cores and Category I2 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I2 Proxy Support Required for Category I2 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category I2 Measured Power in Off at 115 V (W) Required for Category I2 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I2 Measured Power in Off at 230 V (W) Required for Category I2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I2 User-activated Low-power Mode Enabled by Default Required for Category I2 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category I2 User-activated Low-power Mode Enabled by Dflt Other Required if Category I2 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category I2 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category I2 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category I2 Measured Power in Sleep at 115 V (W) Required for Category I2 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I2 Measured Power in Sleep at 230 V (W) Required for Category I2 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I2 Measured Power in Long Idle at 115 V (W) Required for Category I2 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I2 Measured Power in Long Idle at 230 V (W) Required for Category I2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I2 Measured Power in Short Idle at 115 V (W) Required for Category I2 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I2 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I2 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Category I2 Measured Power in Short Idle at 230 V (W) Required for Category I2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I2 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I2 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category I2 TEC at 115 V (kWh) Required for Category I2 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category I2 TEC at 230 V (kWh) Required for Category I2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I2 Base TEC Allowance Required for Category I2 models. O N Integer Min Value: 14
Max Value: 135
Category I2 Functional Adder Allowances (kWh) Required for Category I2 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category I2 Maximum TEC Requirement (Etec max) (kWh) Required for Category I2 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1
Category I3 Operating System Name Required for Category I3 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category I3 Operating System Name Other Required for Category I3 models if Operating System Name is Other. O N Text Max Length: 1000
Category I3 Processor Brand Required for Category I3 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category I3 Processor Name Required for Category I3 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category I3 Processor Name Other Required for Category I3 models if Category I3 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category I3 Installed System Memory RAM (GB) Required for Category I3 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I3 Graphics Category Required for Category I3 models if graphics adder is applicable, when a device has switchable graphics. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category I3 Switchable Graphics Enabled by Default in Ac Mode Required for Category I3 when a device has both integrated graphics and discrete graphics. This setting means that the graphics is switched to integrated graphics when the graphics demand is low. The OEM can provide guidance on detecting what state the graphics is in. This setting is only applicable when a device has both integrated graphics and discrete graphics. O N Enumeration Data
  • Yes
  • No
Category I3 Capable of Switchable Graphics in Battery Mode Required for Category I3 models when a device has switchable graphics. O N Enumeration Data
  • Yes
  • No
Category I3 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category I3 models when a device has switchable graphics. O N Decimal No. of Decimal: 1
Category I3 Discrete Graphics Frame Buffer Data Width (bits) Required for Category I3 models when a device has switchable graphics. O N Integer
Category I3 Gigabit Ethernet Ports (count) Required for Category I3 models. O N Integer Min Value: 0
Category I3 Energy Efficient Ethernet (EEE) Required for Category I3 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category I3 Number of Storage Drives Required for Category I3 models. O N Integer Min Value: 0
Category I3 Number of Integrated Displays (count) Required for Category I3 if integrated display allowance is applicable. O N Integer
Category I3 Integrated Display Resolution (megapixels) Required for Category I3 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I3 Integrated Display Viewable Screen Area (sq in) Required for Category I3 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I3 Enhanced Performance Display Present Required if for Category I3 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category I3 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category I3 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category I3 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category I3 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I3 Internal Power Supply Efficiency at 20% Load Required if for Category I3 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I3 Internal Power Supply Efficiency at 50% Load Required if for Category I3 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I3 Internal Power Supply Efficiency at 100% Load Required if for Category I3 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I3 External Power Supply Average Efficiency Required if for Category I3 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category I3 External/Internal Power Supply Rated Power (W) Required for Category I3 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category I3 Physical CPU Cores (count) Required for Category I3 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category I3 CPU Packages (count) Required for Category I3 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category I3 CPU Base Clock Speed (GHz) Required for Category I3 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I3 CPU Maximum Clock Speed (GHz) Required for Category I3 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I3 Storage Technology Required for Category I3 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category I3 Storage Technology Other Required if Category I3 Storage Technology is Other. O N Text Max Length: 1000
Category I3 Performance Score Required for Category I3 models. Performance Score is the product of Category I3 Physical CPU Cores and Category I3 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I3 Proxy Support Required for Category I3 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category I3 Measured Power in Off at 115 V (W) Required for Category I3 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category I3 Measured Power in Off at 230 V (W) Required for Category I3 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I3 User-activated Low-power Mode Enabled by Default Required for Category I3 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category I3 User-activated Low-power Mode Enabled by Dflt Other Required if Category I3 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category I3 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category I3 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category I3 Measured Power in Sleep at 115 V (W) Required for Category I3 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I3 Measured Power in Sleep at 230 V (W) Required for Category I3 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category I3 Measured Power in Long Idle at 115 V (W) Required for Category I3 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I3 Measured Power in Long Idle at 230 V (W) Required for Category I3 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I3 Measured Power in Short Idle at 115 V (W) Required for Category I3 models tested at 115 V. O N Decimal No. of Decimal: 1
Category I3 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I3 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Category I3 Measured Power in Short Idle at 230 V (W) Required for Category I3 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I3 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category I3 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category I3 TEC at 115 V (kWh) Required for Category I3 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category I3 TEC at 230 V (kWh) Required for Category I3 models tested at 230 V. O N Decimal No. of Decimal: 1
Category I3 Base TEC Allowance Required for Category I3 models. O N Integer Min Value: 14
Max Value: 135
Category I3 Functional Adder Allowances (kWh) Required for Category I3 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category I3 Maximum TEC Requirement (Etec max) (kWh) Required for Category I3 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1
Category D1 Operating System Name Required for Category D1 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category D1 Operating System Name Other Required for Category D1 models if Operating System Name is Other. O N Text Max Length: 1000
Category D1 Processor Brand Required for Category D1 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category D1 Processor Name Required for Category D1 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category D1 Processor Name Other Required for Category D1 models if Category D1 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category D1 Installed System Memory RAM (GB) Required for Category D1 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D1 Graphics Category Required for Category D1 models. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category D1 Switchable Graphics Enabled by Default in Ac Mode Not applicable for Category D1 models. O N Enumeration Data
  • Yes
  • No
Category D1 Capable of Switchable Graphics in Battery Mode Not applicable for Category D1 models. O N Enumeration Data
  • Yes
  • No
Category D1 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category D1 models. O N Decimal No. of Decimal: 1
Category D1 Discrete Graphics Frame Buffer Data Width (bits) Required for Category D1 models. O N Integer
Category D1 Gigabit Ethernet Ports (count) Required for Category D1 models. O N Integer Min Value: 0
Category D1 Energy Efficient Ethernet (EEE) Required for Category D1 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category D1 Number of Storage Drives Required for Category D1 models. O N Integer Min Value: 0
Category D1 Number of Integrated Displays (count) Required for Category D1 if integrated display allowance is applicable. O N Integer
Category D1 Integrated Display Resolution (megapixels) Required for Category D1 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D1 Integrated Display Viewable Screen Area (sq in) Required for Category D1 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D1 Enhanced Performance Display Present Required if for Category D1 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category D1 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category D1 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D1 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category D1 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D1 Internal Power Supply Efficiency at 20% Load Required if for Category D1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D1 Internal Power Supply Efficiency at 50% Load Required if for Category D1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D1 Internal Power Supply Efficiency at 100% Load Required if for Category D1 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D1 External Power Supply Average Efficiency Required if for Category D1 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D1 External/Internal Power Supply Rated Power (W) Required for Category D1 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category D1 Physical CPU Cores (count) Required for Category D1 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category D1 CPU Packages (count) Required for Category D1 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category D1 CPU Base Clock Speed (GHz) Required for Category D1 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D1 CPU Maximum Clock Speed (GHz) Required for Category D1 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D1 Storage Technology Required for Category D1 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category D1 Storage Technology Other Required if Category D1 Storage Technology is Other. O N Text Max Length: 1000
Category D1 Performance Score Required for Category D1 models. Performance Score is the product of Category D1 Physical CPU Cores and Category D1 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D1 Proxy Support Required for Category D1 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category D1 Measured Power in Off at 115 V (W) Required for Category D1 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D1 Measured Power in Off at 230 V (W) Required for Category D1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D1 User-activated Low-power Mode Enabled by Default Required for Category D1 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category D1 User-activated Low-power Mode Enabled by Dflt Other Required if Category D1 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category D1 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category D1 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category D1 Measured Power in Sleep at 115 V (W) Required for Category D1 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category D1 Measured Power in Sleep at 230 V (W) Required for Category D1 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category D1 Measured Power in Long Idle at 115 V (W) Required for Category D1 models tested at 115 V. O N Decimal No. of Decimal: 1
Category D1 Measured Power in Long Idle at 230 V (W) Required for Category D1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D1 Measured Power in Short Idle at 115 V (W) Required for Category D1 models tested at 115 V. O N Decimal No. of Decimal: 1
Category D1 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category D1 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Category D1 Measured Power in Short Idle at 230 V (W) Required for Category D1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D1 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category D1 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category D1 TEC at 115 V (kWh) Required for Category D1 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category D1 TEC at 230 V (kWh) Required for Category D1 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D1 Base TEC Allowance Required for Category D1 models. O N Integer Min Value: 14
Max Value: 135
Category D1 Functional Adder Allowances (kWh) Required for Category D1 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category D1 Maximum TEC Requirement (Etec max) (kWh) Required for Category D1 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1
Category D2 Operating System Name Required for Category D2 models. O Y Enumeration Data
  • Android
  • Chrome
  • iOS
  • Linux
  • Mac OS X
  • Mac OS X Server
  • Other
  • Solaris 10
  • Solaris 9
  • Unix
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows CE
  • Windows Home Server
  • Windows Server 2008
  • Windows XP
Category D2 Operating System Name Other Required for Category D2 models if Operating System Name is Other. O N Text Max Length: 1000
Category D2 Processor Brand Required for Category D2 models. For Product Type Slate/Tablet, Processor Brand will not be included on certified product list. O N Enumeration Data
  • AMD
  • Intel
  • IBM
  • Sun
  • VIA
  • Other
Category D2 Processor Name Required for Category D2 models. For Product Type Slate/Tablet, Processor Name will not be included on certified product list. O Y Enumeration Data
  • Athlon
  • Athlon 64
  • Atom
  • Celeron
  • Core i3
  • Core i5
  • Core i7
  • Core2 Duo
  • Core2 Quad
  • Core M
  • Geode
  • Itanium
  • Itanium 2
  • Nano
  • Neo
  • Opteron
  • Other
  • Pentium
  • Pentium D
  • Pentium IV
  • Phenom X3
  • Phenom X4
  • Xeon
Category D2 Processor Name Other Required for Category D2 models if Category D2 Processor Name is Other. For Product Type Slate/Tablet, Processor Name Other will not be included on certified product list. O N Text Max Length: 1000
Category D2 Installed System Memory RAM (GB) Required for Category D2 models. Provide the memory actually installed in the model tested, not the maximum supported. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D2 Graphics Category Required for Category D2 models. O N Enumeration Data
  • G1
  • G2
  • G3
  • G4
  • G5
  • G6
  • G7
Category D2 Switchable Graphics Enabled by Default in Ac Mode Not applicable for Category D2 models. O N Enumeration Data
  • Yes
  • No
Category D2 Capable of Switchable Graphics in Battery Mode Not applicable for Category D2 models. O N Enumeration Data
  • Yes
  • No
Category D2 Discrete Graphics Frame Buffer Bandwidth (GB/s) Required for Category D2 models. O N Decimal No. of Decimal: 1
Category D2 Discrete Graphics Frame Buffer Data Width (bits) Required for Category D2 models. O N Integer
Category D2 Gigabit Ethernet Ports (count) Required for Category D2 models. O N Integer Min Value: 0
Category D2 Energy Efficient Ethernet (EEE) Required for Category D2 models. Indicate if Energy Efficient Ethernet is supported. O N Enumeration Data
  • Yes
  • No
Category D2 Number of Storage Drives Required for Category D2 models. O N Integer Min Value: 0
Category D2 Number of Integrated Displays (count) Required for Category D2 if integrated display allowance is applicable. O N Integer
Category D2 Integrated Display Resolution (megapixels) Required for Category D2 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D2 Integrated Display Viewable Screen Area (sq in) Required for Category D2 if integrated display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D2 Enhanced Performance Display Present Required if for Category D2 Enhanced-performance Display allowance is applicable. O N Enumeration Data
  • Yes
  • No
Category D2 Enhanced Perform Disp Diagonal Vble Screen Size (in) Required if for Category D2 Enhanced-performance Display allowance is applicable. If multiple integrated displays, provide average. O N Decimal No. of Decimal: 2
Min Value: 0.00
Category D2 Internal/External Pwr Supply Efficiency at 10% Load Required if for Category D2 Power Supply Efficiency allowance is included in test report. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D2 Internal Power Supply Efficiency at 20% Load Required if for Category D2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D2 Internal Power Supply Efficiency at 50% Load Required if for Category D2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D2 Internal Power Supply Efficiency at 100% Load Required if for Category D2 internal power supply is present. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D2 External Power Supply Average Efficiency Required if for Category D2 Power Supply Efficiency allowance is applicable. Provide the simple average of efficiency at 25%, 50%, 75%, and 100% load. O N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 1.00
Category D2 External/Internal Power Supply Rated Power (W) Required for Category D2 models. Provide the nameplate output power which is the power output of the power supply as specified on the manufacturer's label on the power supply housing or, if absent from the housing, as specified in documentation provided by the manufacturer. O N Decimal No. of Decimal: 1
Min Value: 0
Category D2 Physical CPU Cores (count) Required for Category D2 models. Provide the number of physical - not logical - CPU cores. For Product Type Slate/Tablet, Physical CPU Cores will not be included on certified product list. O N Integer Min Value: 0
Category D2 CPU Packages (count) Required for Category D2 models. Provide the number of CPUs/packages. For Product Type Slate/Tablet, CPU Packages will not be included on certified product list. O N Integer Min Value: 0
Category D2 CPU Base Clock Speed (GHz) Required for Category D2 models. Provide the base CPU clock speed, not the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Base Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D2 CPU Maximum Clock Speed (GHz) Required for Category D2 models. Provide the burst, turbo, maximum, temporary, or intermittent clock speed. For Product Type Slate/Tablet, CPU Maximum Clock Speed will not be included on certified product list. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D2 Storage Technology Required for Category D2 models. Provide the storage technology. Hard Disk Drive includes hybrid hard disk drives with flash component. O Y Enumeration Data
  • Hard Disk Drive
  • Solid State Drive
  • Other
Category D2 Storage Technology Other Required if Category D2 Storage Technology is Other. O N Text Max Length: 1000
Category D2 Performance Score Required for Category D2 models. Performance Score is the product of Category D2 Physical CPU Cores and Category D2 CPU Clock Speed in GHz. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D2 Proxy Support Required for Category D2 models. This is a manufacturer-reported parameter. On Mac computers, “Wake for network access” enabled within the Energy Saver/Power Adapter Preferences signifies Base Capability or better. On Windows computers, “ARP Offload” or “NS Offload” or similar enabled within the Advanced Properties of the Network Interface Card (accessed through the Device Manager) signifies Base Capability or better. OEM can provide further guidance on how to confirm Proxy Support. O N Enumeration Data
  • Conventional
  • Base Capability
  • Remote Wake
  • Service Discovery/ Name Services
  • Full Capability
Category D2 Measured Power in Off at 115 V (W) Required for Category D2 models tested at 115 V. O N Decimal No. of Decimal: 1
Min Value: 0.0
Category D2 Measured Power in Off at 230 V (W) Required for Category D2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D2 User-activated Low-power Mode Enabled by Default Required for Category D2 models. Indicate if model offers Sleep Mode enabled by default or another low-latency user-activated mode or state that preserves machine state. O N Enumeration Data
  • Off Mode with Hibernation
  • Sleep Mode
  • Connected Sleep
  • Other
  • None
Category D2 User-activated Low-power Mode Enabled by Dflt Other Required if Category D2 User-activated Low-power Mode Enabled by Default is Other. O N Text Max Length: 1000
Category D2 Long Idle State Pwr Used in Place of Sleep Mode Pwr Required for Category D2 models. Indicate if Long Idle State power is used in place of Sleep Mode power when calculating Typical Energy Consumption (TEC). O N Enumeration Data
  • Yes
  • No
Category D2 Measured Power in Sleep at 115 V (W) Required for Category D2 models tested at 115 V if model has User-activated Low-power Mode Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category D2 Measured Power in Sleep at 230 V (W) Required for Category D2 models tested at 230 V if model has User-activated Low-power Behavior Enabled by Default. Report power in the User-activated Low-power Mode Enabled by Default, if applicable. O N Decimal No. of Decimal: 1
Category D2 Measured Power in Long Idle at 115 V (W) Required for Category D2 models tested at 115 V. O N Decimal No. of Decimal: 1
Category D2 Measured Power in Long Idle at 230 V (W) Required for Category D2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D2 Measured Power in Short Idle at 115 V (W) Required for Category D2 models tested at 115 V. O N Decimal No. of Decimal: 1
Category D2 Additional Measured Power in Short Idle at 115 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category D2 models tested at 115 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Category D2 Measured Power in Short Idle at 230 V (W) Required for Category D2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D2 Additional Measured Power in Short Idle at 230 V (W) Required if Product Type is Notebook or Two-In-One Notebook for Category D2 models tested at 230 V. The display brightness for this additional measurement shall be 150cd/m sq. O N Decimal No. of Decimal: 1
Min Value: 0
Reported Category D2 TEC at 115 V (kWh) Required for Category D2 models tested at 115 V. Provide the Typical Energy Consumption (TEC) which will appear on the ENERGY STAR list of certified products. O N Decimal No. of Decimal: 1
Reported Category D2 TEC at 230 V (kWh) Required for Category D2 models tested at 230 V. O N Decimal No. of Decimal: 1
Category D2 Base TEC Allowance Required for Category D2 models. O N Integer Min Value: 14
Max Value: 135
Category D2 Functional Adder Allowances (kWh) Required for Category D2 models. If no capability adjustments, indicate zero. O N Decimal No. of Decimal: 1
Category D2 Maximum TEC Requirement (Etec max) (kWh) Required for Category D2 models. If no functional adders, indicate Base TEC Allowance. O N Decimal No. of Decimal: 1

Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Computers Version 6.0 or Version 6.1. This template is for desktops, notebooks, integrated desktop computers, slates/tablets, two-in-one notebooks, and portable all-in-one computers. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.