| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Product Specific Information  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
- 1 or 2 Socket Server (neither Blade nor Multi-node)
- 3 or 4 Socket Server (neither Blade nor Multi-node)
- Blade Server
- Multi-node Server
|
| Product Form Factor |
|
R |
N |
Enumeration Data |
|
- Tower/Pedestal
- Rack-mount
- Multi-node
- Blade - Half Chassis
- Blade - Full Chassis
- Other
|
| Base Idle State Power Allowance Category for 1S and 2S Servers |
Required for 1 or 2 Socket Servers. Provide base idle state power allowance category per ENERGY STAR Computer Servers V2.1, Table 3. If not applicable, indicate N/A. |
R |
N |
Enumeration Data |
|
|
| Single Server |
Indicate Yes if certification is for a single server. If certification is for a product family submission, indicate No. |
R |
N |
Enumeration Data |
|
|
| Managed Server |
|
R |
N |
Enumeration Data |
|
|
| Resilient System |
|
R |
N |
Enumeration Data |
|
|
| Number of Nodes for Multi-node |
Required if Product Type is Multi-node. |
O |
N |
Integer |
Min Value: 0
|
|
| Error Correcting Code |
Indicate Yes if all memory options in the system offer Error Correcting Code. |
R |
N |
Enumeration Data |
|
|
| Error Correcting Code Enabled in Hardware as Shipped |
|
R |
N |
Enumeration Data |
|
|
| Available Expansion Slots |
Indicate the number of available expansion slots for I/O Devices and APAs. |
R |
N |
Integer |
Min Value: 0
|
|
| Operating Systems Supported |
|
R |
Y |
Enumeration Data |
|
- Windows
- Linux
- Unix
- Solaris
- SPARC
- Other
|
| Operating Systems Used for Testing |
|
R |
N |
Enumeration Data |
|
- Windows
- Linux
- Unix
- Solaris
- SPARC
- Other
|
| Power Saving Features Available |
|
R |
Y |
Enumeration Data |
|
- Dynamic voltage and frequency scaling of processor(s)
- Processor or core reduced power states
- Power capping
- Variable speed fan control based on power or thermal readings
- Low power memory states
- Low power I/O states
- Other
- None
|
| Power Saving Features Enabled |
Identify Power Saving Features enabled by default upon shipment. |
R |
Y |
Enumeration Data |
|
- Dynamic voltage and frequency scaling of processor(s)
- Processor or core reduced power states
- Power capping
- Variable speed fan control based on power or thermal readings
- Low power memory states
- Low power I/O states
- Other
- None
|
| End User Required Power Saving Features |
Identify Power Saving Features that require the end user to enable them. |
R |
Y |
Enumeration Data |
|
- Dynamic voltage and frequency scaling of processor(s)
- Processor or core reduced power states
- Power capping
- Variable speed fan control based on power or thermal readings
- Low power memory states
- Low power I/O states
- Other
- N/A
|
| Other Power Saving Feature 1: Description |
Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Provide power saving feature. |
O |
N |
Text |
Max Length: 1000
|
|
| Other Power Saving Feature 1: Enabled on Shipment |
Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 1: End-User Enabling Required |
Required if Power Saving Features Available is Other and configuration contains one or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 2: Description |
Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Provide power saving feature. |
O |
N |
Text |
Max Length: 1000
|
|
| Other Power Saving Feature 2: Enabled on Shipment |
Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 2: End-User Enabling Required |
Required if Power Saving Features Available is Other and configuration contains two or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 3: Description |
Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Provide power saving feature. |
O |
N |
Text |
Max Length: 1000
|
|
| Other Power Saving Feature 3: Enabled on Shipment |
Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 3: End-User Enabling Required |
Required if Power Saving Features Available is Other and configuration contains three or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 4: Description |
Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Provide power saving feature. If more than four Power Saving Features, separate features using a semi-colon. |
O |
N |
Text |
Max Length: 1000
|
|
| Other Power Saving Feature 4: Enabled on Shipment |
Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Indicate Yes if Power Saving Feature is enabled by default upon shipment. |
O |
N |
Enumeration Data |
|
|
| Other Power Saving Feature 4: End-User Enabling Required |
Required if Power Saving Features Available is Other and configuration contains four or more other Power Saving Features. Indicate Yes if Power Saving Feature requires the end user to enable it. |
O |
N |
Enumeration Data |
|
|
| APA #1 Model Name |
Required if APA #1 is included in configuration. Indicate model name. |
O |
N |
Text |
Max Length: 1000
|
|
| APA #1 Model Number |
Required if APA #1 is included in configuration. Indicate model number. |
O |
N |
Text |
Max Length: 1000
|
|
| APA #2 Model Name |
Required if APA #2 is included in configuration. Indicate model name. |
O |
N |
Text |
Max Length: 1000
|
|
| APA #2 Model Number |
Required if APA #2 is included in configuration. Indicate model number. |
O |
N |
Text |
Max Length: 1000
|
|
| APA #3 Model Name |
Required if APA #3 is included in configuration. Indicate model name. |
O |
N |
Text |
Max Length: 1000
|
|
| APA #3 Model Number |
Required if APA #3 is included in configuration. Indicate model number. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Power Management Enabled in Hardware on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Processor Power Management Additional Information |
Required if additional processor power management information is available. Provide any additional information on the processor power management that is enabled on shipment including what power management options are deployed. |
O |
N |
Text |
Max Length: 1000
|
|
| Storage Power Management Enabled in Hardware on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Storage Power Management Additional Information |
Required if additional storage power management information is available. Provide any additional information on the storage power management that is enabled on shipment including what power management options are deployed. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Power Management Enabled in Hardware on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Memory Power Management Additional Information |
Required if additional memory power management information is available. Provide any additional information on the memory power management that is enabled on shipment including what power management options are deployed. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Power Management Enabled in Hardware on Shipment |
Indicate if I/O (Input/Output) devices contain power management enabled in hardware on shipment. |
R |
N |
Enumeration Data |
|
|
| I/O Power Management Additional Information |
Required if additional I/O power management information is available. Provide any additional information on the I/O devices power management that is enabled on shipment including what power management options are deployed. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Dynamic Voltage Scaling Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Processor Dynamic Frequency Scaling Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Processor Dynamic Voltage Scaling End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Processor Dynamic Frequency Scaling End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Processor or Core Reduced Power States Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Processor or Core Reduced Power States Enabling Required |
Indicate Yes if the end-user is required to enable processor or core reduced power states. |
R |
N |
Enumeration Data |
|
|
| Power Capping Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Power Capping End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Variable Speed Fan Control Enabled on Shipment |
Indicate Yes if the variable speed fan control based on power or thermal readings is enabled on shipment. |
R |
N |
Enumeration Data |
|
|
| Variable Speed Fan Control End-User Enabling Required |
Indicate Yes if the variable speed fan control based on power or thermal readings is required to be enabled by the end-user. |
R |
N |
Enumeration Data |
|
|
| Low Power Memory States Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Low Power Memory States End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Low Power I/O States Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Low Power I/O States End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Liquid Cooling Capability Enabled on Shipment |
|
R |
N |
Enumeration Data |
|
|
| Liquid Cooling Capability End-User Enabling Required |
|
R |
N |
Enumeration Data |
|
|
| Available Processor Sockets |
|
R |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Available DIMM Slots |
|
R |
N |
Integer |
Min Value: 0
|
|
| Maximum Memory Capacity |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Maximum Number Blade Slots |
Required if Product Type is Blade Server. Indicate the maximum number of blade slots for this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Other Chassis Features |
Required if additional chassis features are available. Indicate additional chassis features such as common storage, networking, etc. for this configuration. |
O |
N |
Text |
Max Length: 1000
|
|
| SERT Version |
Required for models certified using SERT 1.1.0. Indicate the SERT version used for certification. |
O |
N |
Enumeration Data |
|
|
| 64-bit Architecture |
Indicate Yes if 64-bit architecture is supported. Indicate No if only 32-bit architecture is supported. |
O |
N |
Enumeration Data |
|
|
| Model Number or Config ID for Low-end Performance Configuration |
Required if Product Family is Yes. See ENERGY STAR Computer Servers V2.1, Section H.2, for definition of Low-end Performance Configuration. |
O |
N |
Text |
Max Length: 1000
|
|
| SERT Results File for Low-end Performance Configuration |
Required if Product Family is Yes. Provide the renamed SERT-generated results.txt file name for this configuration. Naming convention is as follows: [ENERGY STAR Manufacturing Partner]_[Model Number as listed in core field]_[Low-end Performance Configuration]_[Date Certification Body Notified Partner of Model Certification in MM-DD-YYYY format].txt For example, ENERGY STAR_1000_Low-end Performance Configuration_05-01-2013. The file name uploaded separately to EPA must exactly match the file name listed. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Processors for Low-end Performance Configuration |
Required if Product Family is Yes. If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. |
O |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 1
|
|
| Number of Threads for Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Processor Brand Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Model Name Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Speed for Low-end Performance Configuration (GHz) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Num. of DDR Channels for Low-end Performance Configuration |
Required if Product Family is Yes. Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. |
O |
N |
Integer |
Min Value: 0
|
|
| Memory Manufacturer for Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Model Number Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Speed Low-end Performance Configuration (GHz) |
Indicate the speed of the installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Low-end Performance Configuration Size Per DIMM (GB) |
Required if Product Family is Yes. If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Num. DIMMs for Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Installed Memory for Low-end Performance Configuration (GB) |
Required if Product Family is Yes. Indicate total installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Solid State Drives (SSDs) Low-end Performance Configuration |
Required if Product Family is Yes. Indicate how many SSDs are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Number Rotational Drives Low-end Performance Configuration |
Required if Product Family is Yes. Indicate how many rotational drives are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Manufacturer Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Brand Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Model Number Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Type Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAD Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Link Speed Low-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the I/O device 1 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 1 Num. Active Ports Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Attachment for Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Brand Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Model Number Low-end Performance Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Type Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Link Speed Low-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the I/O device 2 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 2 Ports Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 2 Attachment for Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Brand Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Model Number Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Type Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Link Speed Low-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the I/O device 3 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| I/O Device 3 Ports Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 3 Attachment for Low-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| Low-end Performance Configuration Redundant Power Supply |
Required if Product Family is Yes. Indicate if the power supply unit (PSU) is redundant capable. |
O |
N |
Enumeration Data |
|
|
| Power Supply Type for Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Enumeration Data |
|
- Single-Output
- Multi-Output
|
| Power Supply Manufacturer Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Name Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Number Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Rated Output Low-end Performance Configuration (W) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Power Supplies for Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the number of power supplies installed. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of PSU for Redundancy Low-end Performance Configuration |
Required if Product Family is Yes and the power supply unit (PSU) is redundant capable. |
O |
N |
Integer |
Min Value: 0
|
|
| PSU 80Plus Silver Certified Low-end Performance Configuration |
Required if Product Family is Yes. Indicate if the power supply unit meets the criteria for the 80Plus Silver Certification. |
O |
N |
Enumeration Data |
|
|
| Voltage for Idle Test Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the voltage at which the unit is tested under during the idle testing. |
O |
N |
Enumeration Data |
|
|
| Idle Power Draw for Low-end Performance Configuration (W) |
Required if Product Family is Yes. Report the power draw in watts for the voltage indicated. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Max. Idle Power Allowance Low-end Performance Configuration |
Required if Product Family is Yes and Product Type is One or Two Socket Server. Indicate the maximum idle power allowance for 1 socket and 2 socket servers only. Include the base plus adder values. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Idle Power Low-end Performance Configuration (W) |
Required if Product Family is Yes. Indicate the measured idle power in watts for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Test Frequency for Idle Test Low-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Total Power Dissipation Low-end Performance Configuration (W) |
Required if Product Family is Yes. Indicate the total power dissipation in watts for this configuration during the idle state testing. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| SERT Compress Eff. Score for Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT CryptoAES Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT LU Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU LU Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SOR Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SOR Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT XMLvalidate Efficiency Score Low-end Performance Configuratio |
Required if Product Family is Yes. Indicate the SERT CPU XMLvalidate Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SORT Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SORT Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SHA256 Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Flood Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Flood Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Capacity Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Sequential Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Random Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Random Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SSJ Efficiency Score Low-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Delta Temperature Low-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the delta temperature at exhaust at peak temperature in degrees Celsius for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Peak Temperature Low-end Performance Config (CFM) |
Required if Product Family is Yes. Indicate the airflow at maximum fan speed in cubic feet per minute at peak temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Nominal Temp. Low-end Performance Configuration (CFM) |
Required if Product Family is Yes. Indicate the airflow at nominal fan speed in cubic feet per minute at nominal temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. at Start of Test Low-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at start of testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Idle Test Low-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of idle testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Active Test Low-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of the active testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Tested Num. Blade Slots Low-end Performance Configuration |
Required if Product Family is Yes and Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Model Number or Config ID for Minimum Power Configuration |
Required if Product Family is Yes. See ENERGY STAR Computer Servers V2.1, Section H.2, for definition of Minimum Power Configuration. |
O |
N |
Text |
Max Length: 1000
|
|
| SERT Results File for Minimum Power Configuration |
Required if Product Family is Yes. Provide the renamed SERT-generated results.txt file name for this configuration. Naming convention is as follows: [ENERGY STAR Manufacturing Partner]_[Model Number as listed in core field]_[Minimum Power Configuration]_[Date Certification Body Notified Partner of Model Certification in MM-DD-YYYY format].txt For example, ENERGY STAR_1000_Minimum Power Configuration_05-01-2013. The file name uploaded separately to EPA must exactly match the file name listed. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Processors for Minimum Power Configuration |
Required if Product Family is Yes. If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. |
O |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 1
|
|
| Number of Threads for Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Processor Brand Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Model Name Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Speed for Minimum Power Configuration (GHz) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Num. of DDR Channels for Minimum Power Configuration |
Required if Product Family is Yes. Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. |
O |
N |
Integer |
Min Value: 0
|
|
| Memory Manufacturer for Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Model Number Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Speed Minimum Power Configuration (GHz) |
Indicate the speed of the installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Minimum Power Configuration Size Per DIMM (GB) |
Required if Product Family is Yes. If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Num. DIMMs for Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Installed Memory for Minimum Power Configuration (GB) |
Required if Product Family is Yes. Indicate total installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Solid State Drives (SSDs) Minimum Power Configuration |
Required if Product Family is Yes. Indicate how many SSDs are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Number Rotational Drives Minimum Power Configuration |
Required if Product Family is Yes. Indicate how many rotational drives are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Manufacturer Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Brand Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Model Number Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Type Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAD Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Link Speed Minimum Power Configuration (Gbit) |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the I/O device 1 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 1 Num. Active Ports Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Attachment for Minimum Power Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer Minimum Power Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Brand Minimum Power Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Model Number Minimum Power Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Type Minimum Power Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Link Speed Minimum Power Configuration (Gbit) |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the I/O device 2 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 2 Ports Minimum Power Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 2 Attachment for Minimum Power Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Brand Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Model Number Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Type Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Link Speed Minimum Power Configuration (Gbit) |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the I/O device 3 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| I/O Device 3 Ports Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 3 Attachment for Minimum Power Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| Minimum Power Configuration Redundant Power Supply |
Required if Product Family is Yes. Indicate if the power supply unit (PSU) is redundant capable. |
O |
N |
Enumeration Data |
|
|
| Power Supply Type for Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Enumeration Data |
|
- Single-Output
- Multi-Output
|
| Power Supply Manufacturer Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Name Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Number Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Rated Output Minimum Power Configuration (W) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Power Supplies for Minimum Power Configuration |
Required if Product Family is Yes. Indicate the number of power supplies installed. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of PSU for Redundancy Minimum Power Configuration |
Required if Product Family is Yes and the power supply unit (PSU) is redundant capable. |
O |
N |
Integer |
Min Value: 0
|
|
| PSU 80Plus Silver Certified Minimum Power Configuration |
Required if Product Family is Yes. Indicate if the power supply unit meets the criteria for the 80Plus Silver Certification. |
O |
N |
Enumeration Data |
|
|
| Voltage for Idle Test Minimum Power Configuration |
Required if Product Family is Yes. Indicate the voltage at which the unit is tested under during the idle testing. |
O |
N |
Enumeration Data |
|
|
| Idle Power Draw for Minimum Power Configuration (W) |
Required if Product Family is Yes. Report the power draw in watts for the voltage indicated. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Max. Idle Power Allowance Minimum Power Configuration |
Required if Product Family is Yes and Product Type is One or Two Socket Server. Indicate the maximum idle power allowance for 1 socket and 2 socket servers only. Include the base plus adder values. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Idle Power Minimum Power Configuration (W) |
Required if Product Family is Yes. Indicate the measured idle power in watts for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Test Frequency for Idle Test Minimum Power Configuration |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Total Power Dissipation Minimum Power Configuration (W) |
Required if Product Family is Yes. Indicate the total power dissipation in watts for this configuration during the idle state testing. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| SERT Compress Eff. Score for Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT CryptoAES Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT LU Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT CPU LU Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SOR Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SOR Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT XMLvalidate Efficiency Score Minimum Power Configuratio |
Required if Product Family is Yes. Indicate the SERT CPU XMLvalidate Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SORT Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SORT Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SHA256 Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Flood Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Flood Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Capacity Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Sequential Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Random Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Random Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SSJ Efficiency Score Minimum Power Configuration |
Required if Product Family is Yes. Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Delta Temperature Minimum Power Configuration (C) |
Required if Product Family is Yes. Indicate the delta temperature at exhaust at peak temperature in degrees Celsius for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Peak Temperature Minimum Power Config (CFM) |
Required if Product Family is Yes. Indicate the airflow at maximum fan speed in cubic feet per minute at peak temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Nominal Temp. Minimum Power Configuration (CFM) |
Required if Product Family is Yes. Indicate the airflow at nominal fan speed in cubic feet per minute at nominal temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. at Start of Test Minimum Power Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at start of testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Idle Test Minimum Power Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of idle testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Active Test Minimum Power Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of the active testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Tested Num. Blade Slots Minimum Power Configuration |
Required if Product Family is Yes and Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Model Number or Config ID for Typical or Single Configuration |
See ENERGY STAR Computer Servers V2.1, Section H.2, for definition of Typical or Single Configuration. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| SERT Results File for Typical or Single Configuration |
Provide the renamed SERT-generated results.txt file name for this configuration. Naming convention is as follows: [ENERGY STAR Manufacturing Partner]_[Model Number as listed in core field]_[Typical or Single Configuration]_[Date Certification Body Notified Partner of Model Certification in MM-DD-YYYY format].txt For example, ENERGY STAR_1000_Typical or Single Configuration_05-01-2013. The file name uploaded separately to EPA must exactly match the file name listed. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Installed Processors for Typical or Single Configuration |
If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. |
R |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor Typical or Single Configuration |
|
R |
N |
Integer |
Min Value: 1
|
|
| Number of Threads for Typical or Single Configuration |
|
R |
N |
Integer |
Min Value: 0
|
|
| Processor Brand Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Processor Model Name Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Processor Speed for Typical or Single Configuration (GHz) |
|
R |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Num. of DDR Channels for Typical or Single Configuration |
Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. |
R |
N |
Integer |
Min Value: 0
|
|
| Memory Manufacturer for Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Memory Model Number Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Memory Speed Typical or Single Configuration (GHz) |
Indicate the speed of the installed memory for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Typical or Single Configuration Size Per DIMM (GB) |
If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Installed Num. DIMMs for Typical or Single Configuration |
|
R |
N |
Integer |
Min Value: 0
|
|
| Installed Memory for Typical or Single Configuration (GB) |
Indicate total installed memory for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Solid State Drives (SSDs) Typical or Single Configuration |
Indicate how many SSDs are contained in this configuration. |
R |
N |
Integer |
Min Value: 0
|
|
| Number Rotational Drives Typical or Single Configuration |
Indicate how many rotational drives are contained in this configuration. |
R |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Manufacturer Typical or Single Configuration |
Required if configuration contains one or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 1 Brand Typical or Single Configuration |
Required if configuration contains one or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 1 Model Number Typical or Single Configuration |
Required if configuration contains one or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 1 Type Typical or Single Configuration |
Required if configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAD Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Link Speed Typical or Single Configuration (Gbit) |
Required if configuration contains one or more I/O devices. Indicate the I/O device 1 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 1 Num. Active Ports Typical or Single Configuration |
Required if configuration contains one or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Attachment for Typical or Single Configuration |
Required if configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer Typical or Single Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 2 Brand Typical or Single Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 2 Model Number Typical or Single Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 2 Type Typical or Single Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Link Speed Typical or Single Configuration (Gbit) |
Required if configuration contains two or more I/O devices. Indicate the I/O device 2 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 2 Ports Typical or Single Configuration |
Required if configuration contains two or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 2 Attachment for Typical or Single Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer Typical or Single Configuration |
Required if configuration contains three or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 3 Brand Typical or Single Configuration |
Required if configuration contains three or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 3 Model Number Typical or Single Configuration |
Required if configuration contains three or more I/O devices. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| I/O Device 3 Type Typical or Single Configuration |
Required if configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Link Speed Typical or Single Configuration (Gbit) |
Required if configuration contains three or more I/O devices. Indicate the I/O device 3 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| I/O Device 3 Ports Typical or Single Configuration |
Required if configuration contains three or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 3 Attachment for Typical or Single Configuration |
Required if configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| Typical or Single Configuration Redundant Power Supply |
Indicate if the power supply unit (PSU) is redundant capable. |
R |
N |
Enumeration Data |
|
|
| Power Supply Type for Typical or Single Configuration |
|
R |
N |
Enumeration Data |
|
- Single-Output
- Multi-Output
|
| Power Supply Manufacturer Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Power Supply Model Name Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Power Supply Model Number Typical or Single Configuration |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Power Supply Rated Output Typical or Single Configuration (W) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Power Supplies for Typical or Single Configuration |
Indicate the number of power supplies installed. |
R |
N |
Integer |
Min Value: 0
|
|
| Number of PSU for Redundancy Typical or Single Configuration |
Required if the power supply unit (PSU) is redundant capable. |
O |
N |
Integer |
Min Value: 0
|
|
| PSU 80Plus Silver Certified Typical or Single Configuration |
Indicate if the power supply unit meets the criteria for the 80Plus Silver Certification. |
R |
N |
Enumeration Data |
|
|
| Voltage for Idle Test Typical or Single Configuration |
Indicate the voltage at which the unit is tested under during the idle testing. |
R |
N |
Enumeration Data |
|
|
| Idle Power Draw for Typical or Single Configuration (W) |
Report the power draw in watts for the voltage indicated. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Max. Idle Power Allowance Typical or Single Configuration |
Required if Product Type is One or Two Socket Server. Indicate the maximum idle power allowance for 1 socket and 2 socket servers only. Include the base plus adder values. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Idle Power Typical or Single Configuration (W) |
Indicate the measured idle power in watts for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Test Frequency for Idle Test Typical or Single Configuration |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Total Power Dissipation Typical or Single Configuration (W) |
Indicate the total power dissipation in watts for this configuration during the idle state testing. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| SERT Compress Eff. Score for Typical or Single Configuration |
Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT CryptoAES Efficiency Score Typical or Single Configuration |
Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT LU Efficiency Score Typical or Single Configuration |
Indicate the SERT CPU LU Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SOR Efficiency Score Typical or Single Configuration |
Indicate the SERT CPU SOR Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT XMLvalidate Efficiency Score Typical or Single Configuratio |
Indicate the SERT CPU XMLvalidate Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SORT Efficiency Score Typical or Single Configuration |
Indicate the SERT CPU SORT Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SHA256 Efficiency Score Typical or Single Configuration |
Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Flood Efficiency Score Typical or Single Configuration |
Indicate the SERT Memory Flood Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Capacity Efficiency Score Typical or Single Configuration |
Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Sequential Efficiency Score Typical or Single Configuration |
Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Random Efficiency Score Typical or Single Configuration |
Indicate the SERT Storage Random Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SSJ Efficiency Score Typical or Single Configuration |
Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Delta Temperature Typical or Single Configuration (C) |
Indicate the delta temperature at exhaust at peak temperature in degrees Celsius for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Peak Temperature Typical or Single Config (CFM) |
Indicate the airflow at maximum fan speed in cubic feet per minute at peak temperature for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Nominal Temp. Typical or Single Configuration (CFM) |
Indicate the airflow at nominal fan speed in cubic feet per minute at nominal temperature for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. at Start of Test Typical or Single Configuration (C) |
Indicate the inlet air temperature in degrees Celsius at start of testing for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Idle Test Typical or Single Configuration (C) |
Indicate the inlet air temperature in degrees Celsius at the conclusion of idle testing for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Active Test Typical or Single Configuration (C) |
Indicate the inlet air temperature in degrees Celsius at the conclusion of idle testing for this configuration. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Tested Num. Blade Slots Typical or Single Configuration |
Required if Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Model Number or Config ID for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| SERT Results File for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Processors for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 1
|
|
| Number of Threads for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Processor Brand Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Model Name Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Speed for Maximum Power Configuration (GHz) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Num. of DDR Channels for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Memory Manufacturer for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Model Number Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Speed Maximum Power Configuration (GHz) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Maximum Power Configuration Size Per DIMM (GB) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Num. DIMMs for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Installed Memory for Maximum Power Configuration (GB) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Solid State Drives (SSDs) Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Number Rotational Drives Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Manufacturer Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Brand Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Model Number Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Type Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAD Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Link Speed Maximum Power Configuration (Gbit) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 1 Num. Active Ports Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Attachment for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Brand Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Model Number Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Type Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Link Speed Maximum Power Configuration (Gbit) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 2 Ports Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 2 Attachment for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Brand Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Model Number Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Type Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Link Speed Maximum Power Configuration (Gbit) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| I/O Device 3 Ports Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 3 Attachment for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| Maximum Power Configuration Redundant Power Supply |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| Power Supply Type for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
- Single-Output
- Multi-Output
|
| Power Supply Manufacturer Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Name Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Number Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Rated Output Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Power Supplies for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of PSU for Redundancy Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| PSU 80Plus Silver Certified Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| Voltage for Idle Test Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Enumeration Data |
|
|
| Idle Power Draw for Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Max. Idle Power Allowance Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Idle Power Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Test Frequency for Idle Test Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Total Power Dissipation Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| SERT Compress Eff. Score for Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT CryptoAES Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT LU Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SOR Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT XMLvalidate Efficiency Score Maximum Power Configuratio |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SORT Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SHA256 Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Flood Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Capacity Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Sequential Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Random Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SSJ Efficiency Score Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Delta Temperature Maximum Power Configuration (C) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Peak Temperature Maximum Power Config (CFM) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Nominal Temp. Maximum Power Configuration (CFM) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. at Start of Test Maximum Power Configuration (C) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Idle Test Maximum Power Configuration (C) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Active Test Maximum Power Configuration (C) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Tested Num. Blade Slots Maximum Power Configuration |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Integer |
Min Value: 0
|
|
| Idle Power with APA #1 Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Idle Power with APA #2 Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Idle Power with APA #3 Maximum Power Configuration (W) |
As of V2.1, Maximum Power Configuration fields are no longer required to be reported for certification. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Model Number or Config ID for High-end Performance Configuration |
Required if Product Family is Yes. See ENERGY STAR Computer Servers V2.1, Section H.2, for definition of High-end Performance Configuration. |
O |
N |
Text |
Max Length: 1000
|
|
| SERT Results File for High-end Performance Configuration |
Required if Product Family is Yes. Provide the renamed SERT-generated results.txt file name for this configuration. Naming convention is as follows: [ENERGY STAR Manufacturing Partner]_[Model Number as listed in core field]_[High-end Performance Configuration]_[Date Certification Body Notified Partner of Model Certification in MM-DD-YYYY format].txt For example, ENERGY STAR_1000_High-end Performance Configuration_05-01-2013. The file name uploaded separately to EPA must exactly match the file name listed. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Processors for High-end Performance Configuration |
Required if Product Family is Yes. If Product Type is Blade Server or Multi-node Server indicate the number of installed processors per blade or node. |
O |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 1
|
|
| Number of Threads for High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Processor Brand High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Model Name High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Processor Speed for High-end Performance Configuration (GHz) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Num. of DDR Channels for High-end Performance Configuration |
Required if Product Family is Yes. Include the number of buffered DDR channels per Server/Blade/Node available in the configuration. A buffered DDR channel is defined as a channel or Memory Port connecting a Memory Controller to a defined number of memory devices (e.g. DIMMs) in a computer server. A typical computer server may contain multiple Memory Controllers, which may in turn support one or more Buffered DDR Channels. As such, each Buffered DDR Channel serves only a fraction of the total addressable memory space in a computer server. |
O |
N |
Integer |
Min Value: 0
|
|
| Memory Manufacturer for High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Model Number High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Memory Speed High-end Performance Configuration (GHz) |
Indicate the speed of the installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| High-end Performance Configuration Size Per DIMM (GB) |
Required if Product Family is Yes. If multiple DIMM sizes, separate Gigabyte (GB) values using a semi-colon. |
O |
N |
Text |
Max Length: 1000
|
|
| Installed Num. DIMMs for High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Integer |
Min Value: 0
|
|
| Installed Memory for High-end Performance Configuration (GB) |
Required if Product Family is Yes. Indicate total installed memory for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Solid State Drives (SSDs) High-end Performance Configuration |
Required if Product Family is Yes. Indicate how many SSDs are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Number Rotational Drives High-end Performance Configuration |
Required if Product Family is Yes. Indicate how many rotational drives are contained in this configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Manufacturer High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Brand High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Model Number High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Type High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAD Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Link Speed High-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the I/O device 1 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 1 Num. Active Ports High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 1 Attachment for High-end Performance Configuration |
Required if Product Family is Yes and configuration contains one or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer High-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Brand High-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Model Number High-end Performance Configuration |
Required if configuration contains two or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Type High-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Link Speed High-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the I/O device 2 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
|
|
| I/O Device 2 Ports High-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 2 Attachment for High-end Performance Configuration |
Required if Product Family is Yes and configuration contains two or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Brand High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Model Number High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Type High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Link Speed High-end Performance Configuration (Gbit) |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the I/O device 3 rated link speed per connection in Gbit. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| I/O Device 3 Ports High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. Indicate the number of active ports per configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| I/O Device 3 Attachment for High-end Performance Configuration |
Required if Product Family is Yes and configuration contains three or more I/O devices. |
O |
N |
Enumeration Data |
|
|
| High-end Performance Configuration Redundant Power Supply |
Required if Product Family is Yes. Indicate if the power supply unit (PSU) is redundant capable. |
O |
N |
Enumeration Data |
|
|
| Power Supply Type for High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Enumeration Data |
|
- Single-Output
- Multi-Output
|
| Power Supply Manufacturer High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Name High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Model Number High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Rated Output High-end Performance Configuration (W) |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Num. Power Supplies for High-end Performance Configuration |
Required if Product Family is Yes. Indicate the number of power supplies installed. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of PSU for Redundancy High-end Performance Configuration |
Required if Product Family is Yes and the power supply unit (PSU) is redundant capable. |
O |
N |
Integer |
Min Value: 0
|
|
| PSU 80Plus Silver Certified High-end Performance Configuration |
Required if Product Family is Yes. Indicate if the power supply unit meets the criteria for the 80Plus Silver Certification. |
O |
N |
Enumeration Data |
|
|
| Voltage for Idle Test High-end Performance Configuration |
Required if Product Family is Yes. Indicate the voltage at which the unit is tested under during the idle testing. |
O |
N |
Enumeration Data |
|
|
| Idle Power Draw for High-end Performance Configuration (W) |
Required if Product Family is Yes. Report the power draw in watts for the voltage indicated. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Max. Idle Power Allowance High-end Performance Configuration |
Required if Product Family is Yes and Product Type is One or Two Socket Server. Indicate the maximum idle power allowance for 1 socket and 2 socket servers only. Include the base plus adder values. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Idle Power High-end Performance Configuration (W) |
Required if Product Family is Yes. Indicate the measured idle power in watts for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Test Frequency for Idle Test High-end Performance Configuration |
Required if Product Family is Yes. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Total Power Dissipation High-end Performance Configuration (W) |
Required if Product Family is Yes. Indicate the total power dissipation in watts for this configuration during the idle state testing. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| SERT Compress Eff. Score for High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Central Processing Unit (CPU) Compress Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT CryptoAES Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU CryptoAES Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT LU Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU LU Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SOR Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SOR Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT XMLvalidate Efficiency Score High-end Performance Configuratio |
Required if Product Family is Yes. Indicate the SERT CPU XMLvalidate Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SORT Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SORT Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SHA256 Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT CPU SHA256 Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Flood Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Flood Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Capacity Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Memory Capacity Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Sequential Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Sequential Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT Random Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Storage Random Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| SERT SSJ Efficiency Score High-end Performance Configuration |
Required if Product Family is Yes. Indicate the SERT Hybrid SSJ Worklet efficiency score for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Delta Temperature High-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the delta temperature at exhaust at peak temperature in degrees Celsius for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Peak Temperature High-end Performance Config (CFM) |
Required if Product Family is Yes. Indicate the airflow at maximum fan speed in cubic feet per minute at peak temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Airflow at Nominal Temp. High-end Performance Configuration (CFM) |
Required if Product Family is Yes. Indicate the airflow at nominal fan speed in cubic feet per minute at nominal temperature for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. at Start of Test High-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at start of testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Idle Test High-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of idle testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Air Temp. End Active Test High-end Performance Configuration (C) |
Required if Product Family is Yes. Indicate the inlet air temperature in degrees Celsius at the conclusion of the active testing for this configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Tested Num. Blade Slots High-end Performance Configuration |
Required if Product Family is Yes and Product Type is Blade Server. Indicate the tested number of blade slots for this configuration. |
O |
N |
Integer |
Min Value: 0
|
|