Home > Partner Resources > Third-Party Certification > Certification Body Resources > XML Web Services Submission Process > ENERGY STAR Light Engine and GU24 Based Integrated LED Lamps CSD Template

ENERGY STAR Light Engine and GU24 Based Integrated LED Lamps CSD Template

Service Method: Submit_Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD_1_x
Version Number: V1 Light Engine and GU24 Based Integrated LED Lamps CSD
Description: Information for certification bodies to provide to EPA about LED Light Engines and GU24 Based Integrated LED Lamps. This information is relevant to report light engine models (or LED arrays plus driver(s) combinations that comprise an LED light engine) and GU24 Based Integrated LED Lamps that are certified as meeting the applicable eligibility requirements for the current ENERGY STAR® Program Requirements for Luminaires, including transient protection testing. Test data should be provided at 120 volts. All certified data will be displayed on the CSD. Certified lighting subcomponents will be listed at www.energystar.gov/lightingsubcomponents. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History Subscribe to updates via RSS 2.0:
  • 05/26/16 - Submit_Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD_1_x Updated
  • 08/12/14 - Submit_Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD_1_x Updated
  • 10/23/12 - Submit_Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD_1_x Final
  • 10/09/12 - Submit_Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD_1_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Light_Engine_GU24_Based_Integrated_LED_Lamps_CSD info
ENERGY STAR Specification Version This field is no longer relevant since the CSD web service is not tied to a specific luminaire specification version. The CSD is only intended to facilitate sharing of subcomponent data. Using data from the CSD does not guarantee certification for a luminaire to the ENERGY STAR specification. O N Enumeration Data
  • 1.1
  • 1.2
Product Type R N Enumeration Data
  • LED Light Engines
  • GU24 Based Integrated LED Lamp
Lamp Type Required for GU24 based integrated LED Lamps. Indicate one of the allowable lamp types. O N Enumeration Data
  • Reflector (R, BR, ER)
  • PAR
  • Omnidirectional
  • Decorative
  • Non-Standard
LED Light Engine/Lamp Base Mounting Required if GU24 based integrated LED lamp or LED light engine has one of the connections listed. O N Enumeration Data
  • GU24
  • Zhaga
Indoor/Outdoor Indicate whether the model is intended for indoor and/or outdoor use. R Y Enumeration Data
  • Indoor
  • Outdoor
Reported Voltage (V) Provide the rated/reported voltage(s). R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Tested Voltage (V) Provide the voltage(s) at which the model was tested based on test data. R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Initial Temperature (°C) The initial measured temperature taken at the manufacturer recommended temperature monitoring point required by LM-82. Equal to the temperature of the light engine without the temperature control device attached. R N Integer
First Elevated Temperature (°C) The first elevated temperature at the manufacturer recommended temperature monitoring point required by LM-82. Equal to the initial temperature +25C. R N Integer
Second Elevated Temperature (°C) The second elevated temperature at the manufacturer recommended temperature monitoring point required by LM-82 selected by the manufacturer for data. May be above or below the initial temperature. R N Integer
Reported Input Power (W) Provide the rated/reported input power of the model. R N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
Measured Input Power at Initial Temperature (W) Provide the measured input power of the model based on test data at the Initial Temperature. R N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 250.0
Measured Input Power at First Elevated Temperature (W) Provide the measured input power of the model based on test data at the First Elevated Temperature. R N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 250.0
Measured Input Power at Second Elevated Temperature (W) Provide the measured input power of the model based on test data at Second Elevated Temperature. R N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 250.0
Initial Lumen Output at Initial Temperature (lm) Provide the measured lumen output of the model based on test data at the Initial Temperature. R N Integer
Initial Lumen Output at First Elevated Temperature (lm) Provide the measured lumen output of the model based on test data at the First Elevated Temperature R N Integer
Initial Lumen Output at Second Elevated Temperature (lm) Provide the measured lumen output of the model based on test data at the Second Elevated Temperature. R N Integer
Luminous Efficacy at Initial Temperature (lm/W) Provide the calculated value based on test data at the Initial Temperature. R N Decimal No. of Decimal: 1
Min Value: 29.0
Luminous Efficacy at First Elevated Temperature (lm/W) Provide the calculated value based on test data at the First Elevated Temperature. R N Decimal No. of Decimal: 1
Min Value: 29.0
Luminous Efficacy at Second Elevated Temperature (lm/W) Provide the calculated value based on test data at the Second Elevated Temperature. R N Decimal No. of Decimal: 1
Min Value: 29.0
Power Factor Provide the averaged power factor based on test data. R N Decimal No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00
Operating Frequency (Hz) Provide the average operating frequency based on test data. R N Integer Min Value: 120
Start Time (Milliseconds) Provide the measured start time of the LED light engine based on test data. R N Integer Min Value: 0
Max Value: 1000
Run-Up Time (Seconds) Provide the measured run-up time of the model based on test data. R N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 60.0
Lumen Maintenance Option 1: Initial Temperature (Hours) Required if the model utilizes SSL Option 1 to fulfill lifetime and lumen maintenance requirements. Provide lumen maintenance based on TM-21 Projected Time to L70 for LED temperature with the model at the Initial Temperature. O N Integer Min Value: 25000
Lumen Maintenance Option 1: First Elevated Temperature (Hours) Required if the model utilizes SSL Option 1 to fulfill lifetime and lumen maintenance requirements. Provide lumen maintenance based on TM-21 Projected Time to L70 for LED temperature with the model at the First Elevated Temperature. O N Integer Min Value: 25000
Lumen Maintenance Option 1: Second Elevated Temperature (Hours) Required if the model utilizes SSL Option 1 to fulfill lifetime and lumen maintenance requirements. Provide lumen maintenance based on TM-21 Projected Time to L70 for LED temperature with the model at the Second Elevated Temperature. O N Integer Min Value: 25000
Lumen Maintenance Option 2: Initial Temperature (°C) Required if the model utilizes SSL Option 2 to fulfill lifetime and lumen maintenance requirements. Provide Lumen maintenance based on LM-82 results after 6,000 hours of testing, with the model at the Initial Temperature. O N Decimal No. of Decimal: 3
Min Value: 0.918
Max Value: 1000
Lumen Maintenance Option 2: First Elevated Temperature (°C) Required if the model utilizes SSL Option 2 to fulfill lifetime and lumen maintenance requirements. Provide Lumen maintenance based on LM-82 results after 6,000 hours of testing, with the model at the First Elevated Temperature. O N Decimal No. of Decimal: 3
Min Value: 0.918
Max Value: 1000
Lumen Maintenance Option 2: Second Elevated Temperature (°C) Required if the model utilizes SSL Option 2 to fulfill lifetime and lumen maintenance requirements. Provide Lumen maintenance based on LM-82 results after 6,000 hours of testing, with the model at the Second Elevated Temperature. O N Decimal No. of Decimal: 3
Min Value: 0.918
Max Value: 1000
Color Rendering Index (CRI) Required for indoor and indoor/outdoor models. Provide the CRI value based on test data. O N Integer Min Value: 80
Max Value: 100
Nominal Correlated Color Temperature (CCT) Required for indoor and indoor/outdoor models. O N Enumeration Data
  • 2700K
  • 3000K
  • 3500K
  • 4000/4100K
  • 5000K
Correlated Color Temperature (CCT): Initial Temperature Required for indoor and indoor/outdoor light engines. Provide the measured CCT value at the Initial Temperature based on test data. O N Integer Min Value: 2580
Max Value: 5311
Correlated Color Temperature (CCT): First Elevated Temperature Required for indoor and indoor/outdoor light engines. Provide the measured CCT value at the First Elevated Temperature based on test data. O N Integer Min Value: 2580
Max Value: 5311
Correlated Color Temperature (CCT): Second Elevated Temperature Required for indoor and indoor/outdoor light engines. Provide the measured CCT value at the Second Elevated Temperature based on test data. O N Integer Min Value: 2580
Max Value: 5311
All Samples in ANSI Quadrangle at Initial Temperature Required for indoor and indoor/outdoor models. O N Enumeration Data
  • Yes
  • No
All Samples in ANSI Quadrangle at First Elevated Temperature Required for indoor and indoor/outdoor models. O N Enumeration Data
  • Yes
  • No
All Samples in ANSI Quadrangle at Second Elevated Temperature Required for indoor and indoor/outdoor models. O N Enumeration Data
  • Yes
  • No
Change in Chromaticity at Initial Temperature Required for indoor and indoor/outdoor models. Provide change in chromaticity between 0 and 6,000 hours at the Initial Temperature. O N Decimal No. of Decimal: 3
Max Value: 0.007
Change in Chromaticity at First Elevated Temperature Required for indoor and indoor/outdoor models. Provide change in chromaticity between 0 and 6,000 hours at the First Elevated Temperature O N Decimal No. of Decimal: 3
Max Value: 0.007
Change in Chromaticity at Second Elevated Temperature Required for indoor and indoor/outdoor models. Provide change in chromaticity between 0 and 6,000 hours at the Second Elevated Temperature O N Decimal No. of Decimal: 3
Max Value: 0.007
Minimum Operating Temperature (°C) Required for outdoor and indoor/outdoor light engines. Provide the manufacturer recommended minimum operating temperature. O N Integer Max Value: -18
Dimmable Indicate which dimming mechanism is used, or “Non-Dimmable” for luminaires that are not dimmable. R N Enumeration Data
  • Non-Dimmable
  • Continuous Dimming
  • Step Dimming
Maximum In Situ Temperature (°C) Not required. Maximum temperature (measured or interpolated) at which the light engine will meet all applicable ENERGY STAR requirements, including indoor color requirements (for reference only). O N Decimal No. of Decimal: 1
Maximum Recommended Driver Case Temperature (°C) Provide manufacturer maximum recommended driver case temperature at the designated driver case hot spot location. R N Integer
Reported Beam Angle Not required. Manufacturer reported beam angle (for reference only). O N Integer Min Value: 1
Max Value: 360
Testing Failure Required when EPA has indicated to the CB that the subcomponent failed to meet at least one ENERGY STAR criteria during verification testing. Leave blank unless otherwise instructed by EPA. This information will be displayed on the CSD. O N Enumeration Data
  • Yes

Information for certification bodies to provide to EPA about LED Light Engines and GU24 Based Integrated LED Lamps. This information is relevant to report light engine models (or LED arrays plus driver(s) combinations that comprise an LED light engine) and GU24 Based Integrated LED Lamps that are certified as meeting the applicable eligibility requirements for the current ENERGY STAR® Program Requirements for Luminaires, including transient protection testing. Test data should be provided at 120 volts. All certified data will be displayed on the CSD. Certified lighting subcomponents will be listed at www.energystar.gov/lightingsubcomponents. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.