| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Product Specific Information  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
- Digital picture frame
- Professional display/signage
- Monitor
- Other
|
| Other Product Type |
Required if Product Type is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Display Type |
|
R |
N |
Enumeration Data |
|
- TN LCD
- IPS LCD
- VA LCD
- OLED
- Plasma
- CRT
- Other
|
| Other Display Type |
Required if Display Type is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Display Backlight Technology |
|
R |
N |
Enumeration Data |
|
|
| Other Display Backlight Technology |
Required if Display Backlight Technology is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Display Contrast Ratio |
Indicate the Display Contrast Ratio in the XXX:X format, e.g., 100:1. |
R |
N |
Text |
Min Length: 3
Max Length: 6
|
|
| Viewable Screen Height (in) |
|
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Viewable Screen Width (in) |
|
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Diagonal Viewable Screen Size (in) |
|
R |
N |
Decimal |
No. of Decimal: 1
Max Value: 61.0
|
|
| Viewable Screen Area (sq in) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Aspect Ratio |
Indicate the number as a decimal rounded to the nearest hundredth, e.g., 1.78. |
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Native Resolution Vertical (pixels) |
Indicate the vertical pixels. |
R |
N |
Integer |
|
|
| Native Resolution Horizontal (pixels) |
Indicate the horizontal pixels. |
R |
N |
Integer |
|
|
| Total Native Resolution (megapixels) |
|
R |
N |
Decimal |
No. of Decimal: 3
|
|
| Maximum Resolution Vertical |
Indicate the vertical pixels. |
R |
N |
Integer |
|
|
| Maximum Resolution Horizontal |
Indicate the horizontal pixels. |
R |
N |
Integer |
|
|
| Native Pixel Density (Dp) (pixels/sq in) |
|
R |
N |
Integer |
|
|
| Screen Refresh Rate (Hz) |
|
R |
N |
Integer |
|
|
| Horizontal Viewing Angle (degrees) |
Provide the sum of the left and right horizontal viewing angles, measured from a line normal to the center of the display, in degrees. |
R |
N |
Integer |
Min Value: 0
Max Value: 180
|
|
| Vertical Viewing: Viewing Angle (degrees) |
Provide the sum of the up and down vertical viewing angles, measured from a line normal to the center of the display, in degrees. |
R |
N |
Integer |
Min Value: 0
Max Value: 180
|
|
| Color Gamut |
Provide information on the color gamut of the model (e.g., sRGB 99%, Adobe RGB 96%), which will appear on the ENERGY STAR list of qualified products. |
R |
N |
Text |
Min Length: 3
Max Length: 1000
|
|
| Is Color Gamut at least sRGB? |
Indicate if the color gamut of the model is at least sRGB as defined by IEC 61699 2-1, which will appear on the ENERGY STAR list of qualified products. |
R |
N |
Enumeration Data |
|
|
| Is This Model an Enhanced-Performance Display? |
Required if Product Type is Monitor. |
O |
N |
Enumeration Data |
|
|
| Reported Contrast Ratio at -85° (Left) Horizontal Viewing Angle |
Required if the model is an Enhanced-Performance Display. Provide the rated/reported display screen contrast ratio at a horizontal viewing angle of at least -85 degrees (left) with or without a screen cover glass, in the XXX:X format, e.g., 100:1. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Reported Contrast Ratio at +85° (Right) Horizontal Viewing Angle |
Required if the model is an Enhanced-Performance Display. Provide the rated/reported display screen contrast ratio at a horizontal viewing angle of at least +85 degrees (right) with or without a screen cover glass, in the XXX:X format, e.g., 100:1. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Signal Technology |
|
R |
Y |
Enumeration Data |
|
|
| Is This Model Shipped With an External Power Supply (EPS)? |
|
R |
N |
Enumeration Data |
|
|
| Is Model Sold Through Enterprise Channels? |
|
R |
N |
Enumeration Data |
|
|
| Available Interfaces |
Select all interfaces available with the model. |
R |
Y |
Enumeration Data |
|
- DVI
- HDMI
- EGA
- Mac Compatible
- MPRII
- SVGA
- SXGA
- UXGA
- VGA
- XGA
- VESA
- DisplayPort
- USB 3.0
- Thunderbolt
- IEEE 1394
- RF
- S-Video
- Component
- Composite
- Other
|
| Other Available Interfaces |
Required if Available Interfaces is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Data/Network/Peripheral Ports |
Select all Data/Network/Peripheral Ports available with the model. |
R |
Y |
Enumeration Data |
|
- None
- USB Hubs/Ports
- Ethernet
- DisplayPort
- Thunderbolt
- Flash Memory-card/Smart-card Reader
- Camera Interface
- PictBridge
- Other
|
| Other Data/Network/Peripheral Ports |
Required if Data/Network/Peripheral Ports is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Model Options |
Select all options available with the model. |
R |
Y |
Enumeration Data |
|
- None
- Built-In Speakers
- 3D
- Touch Screen
- Occupancy Sensor
- Tuner/Receiver
- Other
|
| Other Model Options |
Required if Model Options is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Interface |
Provide the Interface used for testing. |
R |
N |
Enumeration Data |
|
- DVI
- HDMI
- VGA
- EGA
- Mac Compatible
- MPRII
- SVGA
- SXGA
- UXGA
- VGA
- XGA
- VESA
- DisplayPort
- USB 3.0
- Thunderbolt
- IEEE 1394
- RF
- S-Video
- Composite
- Component
- Other
|
| Other Interface |
Required if the Interface used for testing is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Data/Network Connection |
Indicate whether the model was tested with any data bridge connections or networking connections, in addition to the video interface connection. |
R |
N |
Enumeration Data |
|
- None
- USB 1.x
- USB 2.x
- USB 3.x
- Fast Ethernet
- Gigabit Ethernet
- WiFi
- DisplayPort
- Thunderbolt
- IEEE 1394
- Other
|
| Other Data/Network Connected |
Required if the Data/Network Connection active during testing is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Source |
Indicate the Power Source used for testing. |
R |
N |
Enumeration Data |
|
- Ac Wall Outlet
- Battery Unit Sold With Ac Adapter
- Data/Network Connection
- Dc Power From a USB Hub
- Other
|
| Other Power Source |
Required if the Power Source used for testing is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| VESA FPDM2 Test Pattern Used? |
Indicate if the VESA FPDM2 test pattern was used for testing. The VESA FPDM2 test pattern can only be used if the model is not capable of displaying IEC signals. |
R |
N |
Enumeration Data |
|
|
| Recommended Image Size (mm) |
Indicate the measured horizontal/vertical size, in the format mm X mm. |
R |
N |
Text |
Min Length: 3
Max Length: 1000
|
|
| Display Has an Integrated Television Tuner? |
|
R |
N |
Enumeration Data |
|
|
| Mechanism for Automatically Entering Sleep or Off Mode? |
Indicate all mechanisms enabled by default that allow the model to automatically enter Sleep or Off Mode. |
R |
Y |
Enumeration Data |
|
- Display Power Management Signaling
- Timer
- Sensor
- Other
|
| Other Mechanism for Automatically Entering Sleep or Off Mode |
Required if Mechanism for Automatically Entering Sleep or Off Mode is Other. |
O |
N |
Text |
Max Length: 1000
|
|
| Default Delay Time to Sleep (min) |
Required for products that have an internal default delay time after which the product transitions from On Mode to Sleep or Off Mode. Indicate the Default Delay Time to Sleep in minutes. |
O |
N |
Integer |
|
|
| Does Model Have a Forced Menu at Initial Start-up? |
|
R |
N |
Enumeration Data |
|
|
| Is Automatic Brightness Control (ABC) Present? |
|
R |
N |
Enumeration Data |
|
|
| Is Automatic Brightness Control (ABC) Enabled by Default? |
Required if Automatic Brightness Control (ABC) is present. Indicate if ABC is enabled when the model is shipped. |
O |
N |
Enumeration Data |
|
|
| Automatic Brightness Control (ABC) Disabled Brightness Mode |
Required if Automatic Brightness Control (ABC) is present and enabled by default. Indicate if the screen brightness can be set to a fixed value after the Automatic Brightness Control (ABC) is disabled. |
O |
N |
Enumeration Data |
|
- Brightness Can Be Set
- Brightness Cannot Be Set
- ABC Cannot Be Disabled
|
| Minimum Luminance (cd/m^2) |
|
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Maximum Measured Luminance (cd/m^2) |
Provide the maximum screen luminance of the On Mode setting in which the display controls, such as brightness and contrast level, are manually configured to a maximum level. Indicate the number in candelas per square meter. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| Maximum Reported Luminance (cd/m^2) |
Provide the maximum screen luminance of the On Mode preset setting in which the display is brightest, as specified by the manufacturer, for example, in the user manual. Indicate the number in candelas per square meter, which will appear on the ENERGY STAR list of qualified products. |
R |
N |
Decimal |
No. of Decimal: 1
|
|
| As-shipped Luminance (cd/m^2) |
Required for all models except models with Automatic Brightness Control (ABC) enabled by default. Indicate the number in candelas per square meter. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| As-tested Luminance (cd/m^2) |
|
R |
N |
Decimal |
No. of Decimal: 1
|
|
| On Mode Power at 10 Lux at 115 Volts (W) |
Required if ABC is enabled by default and the model was tested at 115 volts. Indicate the 115 volt power consumption at 10 lux ambient light conditions (P10) in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| On Mode Power at 300 Lux at 115 Volts (W) |
Required if ABC is enabled by default and the model was tested at 115 volts. Indicate the 115 volt power consumption at 300 lux ambient light conditions (P300) in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured On Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the actual On Mode Power at 115 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Reported On Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the rated/reported Average On Mode Power at 115 volts, which will appear on the ENERGY STAR list of qualified products, in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Sleep Mode Power at 115 Volts (W) |
Required if the model was tested at 115 Volts. Provide the actual Sleep Mode Power at 115 Volts based on test data, in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Reported Sleep Mode Power at 115 Volts (W) |
Required if the model was tested at 115 volts. Provide the rated/reported Average Sleep Mode Power at 115 volts, which will appear on the ENERGY STAR list of qualified products, in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Non-Connected Sleep Mode Power at 115 Volts (W) |
Required if the model was tested with a data/network connection and at 115 volts. Provide the actual Sleep Mode Power with data/networking features deactivated and without any bridge connection established at 115 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Off Mode Power at 115 Volts (W) |
Required if the model has an Off Mode and if it was tested at 115 volts. Provide the actual Off Mode Power at 115 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
Max Value: 0.50
|
|
| Reported Off Mode Power at 115 Volts (W) |
Required if the model has an Off Mode and if it was tested at 115 volts. Provide the rated/reported Average Off Mode Power at 115 volts, which will appear on the ENERGY STAR list of qualified products, in watts. |
O |
N |
Decimal |
No. of Decimal: 2
Max Value: 0.50
|
|
| On Mode Power at 10 Lux at 230 Volts (W) |
Required if ABC is enabled by default and the model was tested at 230 volts. Indicate the 230 volt power consumption at 10 lux ambient light conditions (P10) in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| On Mode Power at 300 Lux at 230 Volts (W) |
Required if ABC is enabled by default and the model was tested at 230 volts. Indicate the 230 volt power consumption at 300 lux ambient light conditions (P300) in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured On Mode Power at 230 Volts (W) |
Required if the model was tested at 230 volts. Provide the actual On Mode Power at 230 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Sleep Mode Power at 230 Volts (W) |
Required if the model was tested at 230 volts. Provide the actual Sleep Mode Power at 230 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Non-Connected Sleep Mode Power at 230 Volts (W) |
Required if the model was tested with a data/network connection and at 230 volts. Provide the actual Sleep Mode Power with data/networking features deactivated and without any bridge connection established at 230 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Measured Off Mode Power at 230 Volts (W) |
Required if the model has an Off Mode and if it was tested at 230 volts. Provide the actual Off Mode Power at 230 volts based on test data in watts. |
O |
N |
Decimal |
No. of Decimal: 2
Max Value: 0.50
|
|
| On Mode Limit (Pon_max) (W) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Sleep Mode Limit (Psleep_ap or Psleep_max) (W) |
|
R |
N |
Decimal |
No. of Decimal: 2
|
|
| Off Mode Limit (Poff_max) (W) |
|
R |
N |
Decimal |
No. of Decimal: 2
Max Value: 0.50
|
|
| True Power Factor (PF) During On Mode Testing |
Indicate the power factor (PF) averaged over the entire duration of On Mode testing. |
R |
N |
Decimal |
No. of Decimal: 2
Max Value: 1.00
|
|
| Low-Voltage Dc Source Power (Pl) (W) |
Required if the power source was a low-voltage dc source. Indicate the ac power consumption (Pl) of the low-voltage dc source with the model as the load, in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Adder for an Enhanced-Performance Display (W) |
Required if the model is an Enhanced-Performance Display. Indicate the amount of watts added to the Maximum On Mode power due to the Enhanced-Performance Display adder in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Adder for Automatic Brightness Control (W) |
Required if the model is shipped with ABC enabled by default. Indicate the amount of watts added to the Maximum On Mode power due to the ABC adder in watts. |
O |
N |
Decimal |
No. of Decimal: 2
|
|
| Number of Sleep Modes in Addition to Default Sleep Mode |
|
R |
N |
Enumeration Data |
|
|