| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Platforms_CSD  |
| ENERGY STAR Specification Version |
This field is no longer relevant since the CSD web service is not tied to a specific luminaire specification version. The CSD is only intended to facilitate sharing of subcomponent data. Using data from the CSD does not guarantee certification for a luminaire to the ENERGY STAR specification. |
O |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
|
| Ballast Manufacturer's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the Ballast Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Lamp Manufacturer's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the Lamp Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Listing Status |
Indicate whether the platform has achieved initial qualification (lamp testing at 40% of rated life) or full qualification at 100% of rated life. |
R |
N |
Enumeration Data |
|
- Initial Qualification
- Full Qualification
|
| Date Fully Qualified |
If listing status is "Full Qualification" provide the date the platform achieved full qualification at 100% of rated life. |
O |
N |
Date |
|
|
| Indoor/Outdoor |
Indicate whether the platform is intended for indoor use, outdoor use, or both. |
R |
N |
Enumeration Data |
|
|
| Platform Measured Voltage (V) |
Provide the voltage at which the model was tested based on laboratory reports. |
R |
N |
Enumeration Data |
|
|
| Platform Reported Voltage (V) |
Provide the manufacturer rated operating voltage. |
R |
Y |
Enumeration Data |
|
|
| Generic Lamp Designation |
If lamp can be classified using an ANSI Generic Lamp Designation or ANSI code, provide the ANSI generic lamp designation or ANSI Code for the tested lamp. |
O |
N |
Text |
Max Length: 1000
|
|
| Lamp Maximum Diameter (MOD) |
Provide the measured lamp maximum diameter in millimeters. If multiple samples were tested, report the average value. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Lamp Maximum Length (MOL) |
Provide the actual lamp maximum length in millimeters. If multiple samples were tested, report the average value. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| ANSI-IEC Designated Lamp Base Type |
If the lamp uses an ANSI-IEC Designated Lamp Base, provide the lamp base type. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| ANSI-IEC Standardized Lamp Shape |
If the lamp uses an ANSI-IEC Designated Lamp Shape, provide the lamp shape. |
O |
N |
Text |
Max Length: 1000
|
|
| ANSI-IEC Designated Lamp Data Sheet Number |
If the lamp has an ANSI-IEC standard data sheet number, provide the number. |
O |
N |
Text |
Max Length: 1000
|
|
| Tested Number of Lamps per Ballast |
Provide the number of lamps powered by the ballast during testing. |
O |
N |
Integer |
|
|
| Testing Orientation |
|
R |
N |
Enumeration Data |
|
- 50% Base Up/50% Base Down
- All Base Up
- All Base Down
- Horizontal
|
| Reported Input Power (W) |
Provide the rated/reported input power of the lamp model, which will appear on the CSD. |
R |
N |
Integer |
Max Value: 250
|
|
| Measured Input Power (W) |
Provide the measured input power of the model based on test data. |
O |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
|
|
| Lumen Maintenance at 4,000 hours or at 40% of Rated Life |
Provide the lumen maintenance (in decimal format) of the lamp at 4,000 hours or 40% of rated life based on test data. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.80
Max Value: 1.00
|
|
| Light Source Life (Hours) |
Provide the average rated light source life based on laboratory test reports. |
R |
N |
Integer |
Min Value: 10000
|
|
| Color Rendering Index (CRI) |
Required for indoor or indoor/outdoor lamps. Take the calculated CRIs of the ten samples, average them, and provide this average value. |
O |
N |
Integer |
Min Value: 80
Max Value: 100
|
|
| Measured Lamp Correlated Color Temperature (CCT) |
Required for indoor and indoor/outdoor lamps. Provide the measured CCT. |
O |
N |
Integer |
Min Value: 2580
Max Value: 5311
|
|
| Nominal Lamp Correlated Color Temperature (CCT) |
Required for indoor and indoor/outdoor lamps. |
O |
N |
Enumeration Data |
|
- 2700K
- 3000K
- 3500K
- 4000/4100K
- 5000K
|
| Percentage of Samples within 7-step MacAdam Ellipse |
Required for indoor and indoor/outdoor lamps. Express value in decimal format. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.90
Max Value: 1.00
|
|
| Lamp Minimum Starting Temperature (ºC) |
Required for outdoor and indoor/outdoor only. |
O |
N |
Integer |
Min Value: -18
|
|
| Maximum Number of Lamps Tested per Ballast |
|
R |
N |
Integer |
Min Value: 1
|
|
| Ballast Factor |
Provide the average ballast factor of the samples tested based on lab reports. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 2.0
|
|
| Current Crest Factor |
Provide the average ballast current crest factor of the samples tested based on lab reports. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0
Max Value: 1.7
|
|
| Ballast Rated Life (Hours) |
Provide manufacturer's declared rated life. |
R |
N |
Integer |
|
|
| Dimmable |
|
R |
N |
Enumeration Data |
|
|
| Dimming Mechanism |
Indicate whether the ballast is continuously dimmable or step dimmable. |
R |
N |
Enumeration Data |
|
- Continuous Dimming
- Step Dimming
- N/A
|
| Ballast Frequency (Hz) |
Provide the average operating frequency of the samples tested based on lab reports. |
R |
N |
Integer |
Min Value: 20000
|
|
| Minimum Operating Temperature (ºC) |
Required for outdoor and indoor/outdoor only. Provide the manufacturer recommended minimum operating temperature. |
O |
N |
Integer |
Max Value: -18
|
|
| Ballast Hotspot Location Labeled? |
Indicate whether the ballast hotspot location is labeled on the packaging/label/ballast. |
R |
N |
Enumeration Data |
|
|
| Power Factor |
Provide the average power factor of the samples tested based on lab reports. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00
|
|
| Platform Measured Input Power |
Provide the measured input power of the model tested based on test data. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0
Max Value: 250.0
|
|
| Platform Reported Input Power |
Provide the rated/reported input power of the model, which will appear on the CSD. |
R |
N |
Integer |
Min Value: 0
Max Value: 250
|
|
| Platform Total Measured Lumen Output |
Provide the measured lumen output of the model based on test data. |
R |
N |
Integer |
|
|
| Platform Reported Initial Lamp Lumens |
Report the initial lumens of each lamp. If testing more than one type of lamp, report each lamp's initial lumens. |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Platform System Efficacy (lm/W) |
Provide the calculated value based on measured test data. |
R |
N |
Decimal |
|
|
| Platform Start Time (Milliseconds) |
Required for indoor and indoor/outdoor platforms. Provide the actual start time of the platform based on test data. |
O |
N |
Integer |
Min Value: 0
Max Value: 1000
|
|
| Platform Run-up Time (Seconds) |
Required for indoor and indoor/outdoor platforms. Provide the actual run-up time of the model based on test data. |
O |
N |
Decimal |
No. of Decimal: 1
Min Value: 0
Max Value: 180.0
|
|
| Platform Minimum Starting Temperature (ºC) |
Required for outdoor and indoor/outdoor platforms. Provide the manufacturer recommended minimum operating temperature. |
O |
N |
Integer |
Max Value: -18
|
|
| Testing Failure |
Required when EPA has indicated to the CB that the subcomponent failed to meet at least one ENERGY STAR criteria during verification testing. Leave blank unless otherwise instructed by EPA. This information will be displayed on the CSD. |
O |
N |
Enumeration Data |
|
|