Home > Partner Resources > Third-Party Certification > Certification Body Resources > XML Web Services Submission Process > ENERGY STAR Directional Luminaires Shipped with ENERGY STAR Lamps Template

ENERGY STAR Directional Luminaires Shipped with ENERGY STAR Lamps Template

Service Method: Submit_Directional_Luminaires_Shipped_with_ENERGY_STAR_Lamps_2_x
Version Number: V2 Directional Luminaires Shipped with ENERGY STAR Lamps
Description: Information for certification bodies to provide to EPA on Indoor and Indoor/Outdoor and Outdoor Directional Luminaires shipped with ENERGY STAR Lamps certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 2.1 and 2.2 and ENERGY STAR® Program Requirements for Lamps V2.0 or V2.1. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History Subscribe to updates via RSS 2.0:
  • 08/15/19 - Submit_Directional_Luminaires_Shipped_with_ENERGY_STAR_Lamps_2_x Updated
  • 05/11/18 - Submit_Directional_Luminaires_Shipped_with_ENERGY_STAR_Lamps_2_x Final
  • 05/02/18 - Submit_Directional_Luminaires_Shipped_with_ENERGY_STAR_Lamps_2_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Product Specific Information info
ENERGY STAR Luminaires Specification Version R N Enumeration Data
  • 2.1
  • 2.2
Product Type R N Enumeration Data
  • Directional Luminaire with ENERGY STAR Lamps
Indoor/Outdoor Indicate whether the luminaire is intended for indoor or indoor and outdoor use. R N Enumeration Data
  • Indoor
  • Indoor/Outdoor
  • Outdoor only
Reported Voltage (V) Provide the rated/reported voltage(s). R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Lighting Technology R N Enumeration Data
  • LED
  • Fluorescent
Directional Luminaire Type Indicate one of the allowable luminaire types. R Y Enumeration Data
  • Accent Light Line-voltage
  • Downlight Recessed
  • Downlight Pendant Mount
  • Downlight Surface Mount
  • Downlight Solid State Retrofit
  • Under Cabinet
  • Cove Mount
  • Outdoor Post Mount
  • Outdoor Pendant Mount
  • Outdoor Porch Light
  • Outdoor Security
  • Outdoor Wall Mount
  • Portable Desk Task Light
ENERGY STAR Lamp ESUID Provide the least efficient ENERGY STAR certified lamp ENERGY STAR Unique ID (ESUID) used in the luminaire, which will appear on the list of ENERGY STAR certified products. Certified lamp ESUID must appear on the ENERGY STAR certified light bulbs (lamps) products list for luminaire model to be included on the ENERGY STAR certified light fixtures (luminaires) products list. R N Integer
ENERGY STAR Lamp Alternate ESUIDs Required if alternate applicable ENERGY STAR certified lamp(s) used in the luminaire. Provide alternate ENERGY STAR Unique IDs (ESUIDs), which will appear on the list of ENERGY STAR certified products. Certified lamps ESUIDs must appear on the ENERGY STAR certified light bulbs (lamps) products list to be included on the ENERGY STAR certified light fixtures (luminaires) products list. O Y Integer
Number of Light Sources per Luminaire R N Integer
Luminous Efficacy (lm/W) Provide the calculated value based on test data using luminaire photometry to minimize confusion about source vs. luminaire testing. R N Decimal No. of Decimal: 1
Min Value: 50.0
Reported Light Output (lm) Provide the reported total light output of the model (i.e. all light sources). This value may only be more conservative than Measured Light Output. For color tunable luminaires, provide the performance at the least efficient white light setting. R N Integer
Measured Light Output (lm) Provide the measured total light output of the model based on test data using luminaire photometry to minimize confusion about source vs. luminaire testing. R N Integer
Default Setting Output (lm) For color tunable luminaires only. Provide the measured lumen output of the default setting. O N Integer
Luminaire Zonal Lumen Density Required for luminaires classified as Cove or Under Cabinet Mount, Downlight, SSL downlight retrofit, Accent, or Portable Desk Task. Indicate the percentage of light falling within 0°-60° zone, in decimal format (i.e., use .60 for 60%). O N Decimal No. of Decimal: 2
Min Value: 0.60
Max Value: 1.00
Luminaire Features Required for all V2.2 certifications. Select as applicable. If product contains no special features, select “none”. O Y Enumeration Data
  • None
  • Occupancy Sensor
  • Dusk to Dawn Sensor
  • Outdoor Rated
  • Damp Location Rated
  • Wet Location Rated
  • USB Charger
  • AC Outlet
Connected Luminaire Indicate whether the luminaire meets the criteria to be recognized as connected. R N Enumeration Data
  • Yes
  • No
Communication Standard - Media/Network Layer Required if Connected Luminaire is Yes. Select all that apply. O Y Enumeration Data
  • Wired Ethernet
  • Wi-Fi
  • Zigbee
  • HomePlug Green PHY
  • 6LoWPAN
  • Z-Wave
  • Other
Communication Standard - Media/Network Layer Other Required if Communication Standard - Media/Network Layer is Other. Indicate relevant standard(s). O N Text Max Length: 1000
Displayed Luminaire Notes Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model’s listing, etc.). O N Text Max Length: 1000

Information for certification bodies to provide to EPA on Indoor and Indoor/Outdoor and Outdoor Directional Luminaires shipped with ENERGY STAR Lamps certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 2.1 and 2.2 and ENERGY STAR® Program Requirements for Lamps V2.0 or V2.1. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.