ENERGY STAR Electric Vehicle Supply Equipment Template

Service Method: Submit_Electric_Vehicle_Supply_Equipment_1_x
Version Number: V1
Description: Information for certification bodies to provide to EPA on products certified or registered as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Electric Vehicle Supply Equipment (EVSE) Version 1.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History Subscribe to updates via RSS 2.0:
  • 02/14/17 - Submit_Electric_Vehicle_Supply_Equipment_1_x Updated
  • 01/27/17 - Submit_Electric_Vehicle_Supply_Equipment_1_x Final
  • 01/11/17 - Submit_Electric_Vehicle_Supply_Equipment_1_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Product Specific Information info
ENERGY STAR Specification Version R N Enumeration Data
  • 1.0
Product Type Indicate for this model which type of EVSE describes it. R N Enumeration Data
  • Level 1
  • Level 2
  • Level 1/Level 2 Dual Input
National Electric Code Product Safety Standards Met Indicate which safety standards are met by this model. R Y Enumeration Data
  • UL 2594
  • UL 2231
  • UL 1998
Network Protocol with Wake Capability Indicate which, if any, network protocols the model is shipped with, and None if the model does not have any network connected capability. You can select multiple network protocols if the model has the capability for multiple protocols. R Y Enumeration Data
  • Wi-Fi or Gigabit Ethernet
  • Cellular
  • Other LAN (Local Area Network)
  • None
Other LAN Network Protocol with Wake Capability Required if Network Protocol with Wake Capability is Other. Indicate what ‘other’ LAN protocol is present. O N Text Min Length: 0
Max Length: 1000
Network Protocol Enabled During Testing Required if one or multiple Network Protocols with Wake Capability were selected above. Indicate which capability, if any, is enabled by default/enabled during this testing. O N Enumeration Data
  • Wi-Fi or Gigabit Ethernet
  • Cellular
  • Other LAN (Local Area Network)
Other LAN Network Protocol Enabled During Testing Required if Network Protocol Enabled During Testing is Other. Indicate what ‘other’ LAN protocol is enabled. O N Text Min Length: 0
Max Length: 1000
Presence of Full Network Connectivity Indicate if there is presence of full network connectivity in Partial On Mode according to Section 4.1.1 of the specification. R N Enumeration Data
  • Present
  • Not Present
Input Cord Length (ft.) Enter input cord length used for test or mean cord length if it varies for multiple-input EVSE. Enter 0 if none. R N Integer Min Value: 0
Input Cord Gauge (AWG) Enter American Wire Gauge (AWG) of the current-carrying line (L) and neutral (N) conductors used for test or mean conductor AWG if it varies. Enter N/A if none. R N Text Min Length: 1
Max Length: 4
Output Cord Length (ft.) Enter output cord length used for test or mean cord length if it varies for multiple-input EVSE. Enter 0 if none. R N Integer Min Value: 0
Output Cord Gauge (AWG) Enter American Wire Gauge (AWG) of the current-carrying line (L) and neutral (N) conductors used for test or mean conductor AWG if it varies. Enter N/A if none. R N Text Min Length: 1
Max Length: 4
Screen Area, if EVSE has high res display (in2) Required if EVSE has a high resolution display. O N Decimal No. of Decimal: 2
Maximum (100%) Measured Luminance of the High Res Display Required if EVSE has a high resolution display (candelas per m2). O N Decimal No. of Decimal: 2
Maximum (100%) Measured Luminance of the High Res Display Image Required if EVSE has a high resolution display. Indicate if the model displayed the three-bar pattern specified in IEC 62087:2011, Section 11.5.5 or if it displayed the default image that appears as-shipped. O N Enumeration Data
  • IEC Test Pattern
  • Default Image
Measured Luminance at 65% of Max Brightness of High Res Display Required if EVSE has a high resolution display (candelas per m2). O N Decimal No. of Decimal: 2
Automatic Brightness Control (ABC) Capable? Indicate if this model is capable of the self-acting mechanism that controls the brightness of a display or lamp as a function of ambient light. R N Enumeration Data
  • Yes
  • No
Automatic Brightness Control Enabled As-shipped? Required if model is ABC capable. Indicate Yes if model is shipped with this capability and it is enabled by default. O N Enumeration Data
  • Yes
  • No
Connected Functionality Capable? Indicate if this model is capable of Connected Functionality as defined in the specification. R N Enumeration Data
  • Yes
  • No
Connected Functionality Capabilities Summary Required if this model is capable of Connected Functionality. A ≤250 word summary description of the EVSE system’s and/or associated Service Provider’s DR capabilities/services shall be submitted per Section 3.6.4 of the specification. O N Text Min Length: 0
Max Length: 4000
Max Nameplate Output Current (A) Indicate the Maximum Nameplate Output Current for every model. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
Dual Input Max Nameplate Output Current (A) Required for dual-input Level 1/2 models, indicate the Level 2 Maximum Nameplate Output Current. O N Decimal No. of Decimal: 2
Input Voltage (V) Indicate the Input Voltage for every model. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
Dual Input Voltage (V) Required for dual-input Level 1/2 models, indicate the Level 2 Input Voltage. O N Decimal No. of Decimal: 2
Number of Outputs Indicate the number of outputs available for every model. For dual-input Level 1/2 models, indicate the Level 1 value. R N Integer Min Value: 0
Max Value: 20
Dual Input Number of Outputs Required for dual-input Level 1/2 models, indicate the Level 2 number of outputs available. O N Decimal No. of Decimal: 2
High Illuminance for ABC Room Illuminance (lux) Required for models with ABC enabled during testing (in the high illuminance condition of 300 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance for ABC or Default No Vehicle Mode Input Power Indicate the No Vehicle Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
No Vehicle Mode Total Allowance (W) Indicate the No Vehicle Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance for ABC or Default No Vehicle Mode Power Factor Indicate the No Vehicle Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance for ABC or Default Partial On Mode Input Power Indicate the Partial On Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
Partial On Mode Total Allowance (W) Indicate the Partial On Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance for ABC or Default Partial On Mode Power Factor Indicate the Partial On Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance for ABC or Default Idle Mode Input Power (W) Indicate the Idle Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
Idle Mode Total Allowance (W) Indicate the Idle Mode Total Allowance value. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance for ABC or Default Idle Mode Power Factor Indicate the Idle Mode power factor value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
Full Current Operation Mode Test: UUT Available Current Indicate the Full Current Operation Mode Test: UUT Available Current. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance Full Current Operation Mode: Input Power Indicate the Full Current Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance Full Current Operation Mode: Output Power Indicate the Full Current Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. R N Decimal No. of Decimal: 2
High Illuminance 30 A Operation Mode: Input Power Required if Full Current is ≥ 30 A. Indicate the 30 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance 30 A Operation Mode: Output Power Required if Full Current is ≥ 30 A models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance 15 A Operation Mode Test: Input Power Required if Full Current is ≥ 15 A. Indicate the 15 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance 15 A Operation Mode Test: Output Power Required if Full Current is ≥ 15 A. Indicate the 15 A Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance 4 A Operation Mode Test: Input Power Required if Full Current is ≥ 4 A. Indicate the 4 A Operation Mode Input Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
High Illuminance 4 A Operation Mode Test: Output Power Required if Full Current is ≥ 4 A. Indicate the 4 A Operation Mode Output Power value for models with ABC enabled during testing (in the high illuminance condition of 300 lux) or the default value for all other models without ABC enabled during testing. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance for ABC Room Illuminance (lux) Required for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance No Vehicle Mode Input Power (W) Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance No Vehicle Mode Power Factor Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in No Vehicle Mode. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Partial On Mode Input Power (W) Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Partial On Mode Power Factor Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in Partial On Mode. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Idle Mode Input Power (W) Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Idle Mode Power Factor Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the power factor for this model in Idle Mode. For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Full Current Mode Test: Input Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance Full Current Operation Mode Test: Output Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 30 A Operation Mode Test: Input Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 30 A Operation Mode Test: Output Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 15 A Operation Mode Test: Input Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 15 A Operation Mode Test: Output Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 4 A Operation Mode Test: Input Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Low Illuminance 4 A Operation Mode Test: Output Power Required only for models with ABC enabled during testing (in the low illuminance condition of 10 lux). For dual-input Level 1/2 models, indicate the Level 1 value. O N Decimal No. of Decimal: 2
Dual Input High Illuminance for ABC Room Illuminance (lux) Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the high illuminance condition of 300 lux). Indicate the Level 2 ABC Room Illuminance value. O N Decimal No. of Decimal: 2
Dual Input High Illuminance No Vehicle ModeInput Power (W) Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input No Vehicle Mode Total Allowance (W) Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Total Allowance value. O N Decimal No. of Decimal: 2
Dual Input High Illuminance No Vehicle Mode Power Factor Required for dual-input Level 1/2 models, indicate the Level 2 No Vehicle Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illuminance Partial On Mode Input Power (W) Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input Partial On Mode Total Allowance (W) Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Total Allowance value. O N Decimal No. of Decimal: 2
Dual Input High Illuminance Partial On Mode Power Factor Required for dual-input Level 1/2 models, indicate the Level 2 Partial On Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illuminance Idle Mode Input Power (W) Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input Idle Mode Total Allowance (W) Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Total Allowance value. O N Decimal No. of Decimal: 2
Dual Input High Illuminance Idle Mode Power Factor Required for dual-input Level 1/2 models, indicate the Level 2 Idle Mode Power Factor value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input Full Current Operation Mode Test Available Current Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: UUT Available Current value. O N Decimal No. of Decimal: 2
Dual Input High Illumin. Full Current Operation Mode Input Power Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illumin. Full Current Operation ModeOutput Power Required for dual-input Level 1/2 models, indicate the Level 2 Full Current Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illumin. 30 A Operation Mode Test: Input Power Required for dual-input Level 1/2 models, indicate the Level 2 30 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illumin. 30 A Operation Mode Test: Output Power Required for dual-input Level 1/2 models, indicate the Level 2 30 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illumin. 15 A Operation Mode Test: Input Power Required for dual-input Level 1/2 models, indicate the Level 2 15 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illumin. 15 A Operation Mode Test: Output Power Required for dual-input Level 1/2 models, indicate the Level 2 15 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illuminance 4 A Operation Mode: Input Power Required for dual-input Level 1/2 models, indicate the Level 2 4 A Operation Mode Test: Input Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input High Illuminance 4 A Operation Mode: Output Power Required for dual-input Level 1/2 models, indicate the Level 2 4 A Operation Mode Test: Output Power value. If the model is ABC enabled during testing, indicate in the high illuminance condition of 300 lux. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance for ABC Room Illuminance (lux) Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 ABC Room Illuminance value. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance No Vehicle Mode Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 No Vehicle Mode Input Power value in Watts.. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance No Vehicle Mode Power Factor Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 No Vehicle Mode Power Factor value. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance Partial On Mode Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Partial On Mode Input Power value in Watts. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance Partial On Mode Power Factor Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Partial On Mode Power Factor value. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance Idle Mode Input Power (W) Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Idle Mode Input Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illuminance Idle Mode Power Factor Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Idle Mode Power Factor value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. Current Operation Mode Test: Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Full Current Operation Mode Test: Input Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. Current Operation Mode Test:Output Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 Full Current Operation Mode Test: Output Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 30 A Operation Mode Test: Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 30 A Operation Mode Test: Input Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 30 A Operation Mode Test: Output Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 30 A Operation Mode Test: Output Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 15 A Operation Mode Test: Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 15 A Operation Mode Test: Input Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 15 A Operation Mode Test: Output Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 15 A Operation Mode Test: Output Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 4 A Operation Mode Test: Input Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 4 A Operation Mode Test: Input Power value. O N Decimal No. of Decimal: 2
Dual Input Low Illumin. 4 A Operation Mode Test: Output Power Required for dual-input Level 1/2 models that are also ABC enabled during testing (in the low illuminance condition of 10 lux). Indicate the Level 2 4 A Operation Mode Test: Output Power value. O N Decimal No. of Decimal: 2

Information for certification bodies to provide to EPA on products certified or registered as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Electric Vehicle Supply Equipment (EVSE) Version 1.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.