ENERGY STAR Non-Directional/Decorative Lamps Template

Service Method: Submit_Non_Directional_Decorative_Lamps_2_x
Version Number: V2 Non-Directional Decorative
Description: Information for certification bodies to provide to EPA on Non-Directional/Decorative Lamps certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Lamps V2.0 and V2.1. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.
History Subscribe to updates via RSS 2.0:
  • 09/28/17 - Submit_Non_Directional_Decorative_Lamps_2_x Updated
  • 02/03/16 - Submit_Non_Directional_Decorative_Lamps_2_x Final
  • 02/01/16 - Submit_Non_Directional_Decorative_Lamps_2_x Updated
  • 01/14/16 - Submit_Non_Directional_Decorative_Lamps_2_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Non_Directional_Decorative_Lamps info
ENERGY STAR Specification Version R N Enumeration Data
  • 2.0
  • 2.1
Lamp Only Available in an ENERGY STAR Certified Luminaire Indicate Yes if the model is only available in an ENERGY STAR Certified Luminaire. R N Enumeration Data
  • Yes
  • No
Lamp Category Indicate if the model is omnidirectional, directional, or decorative. R N Enumeration Data
  • Omnidirectional
  • Decorative
Technology Used Indicate if the model utilizes CFL or LED to generate the light. R N Enumeration Data
  • CFL
  • LED
Certification Status Indicate whether the light source has achieved initial certification or full certification. R N Enumeration Data
  • Initial Certification
  • Full Certification
Base Type Indicate one of the allowable base types. R N Enumeration Data
  • E26
  • E26d
  • E17
  • E11
  • E12
  • G4
  • G9
  • GU10
  • GU24
  • GU5.3
  • GX5.3
Tested Voltage (V) Provide the voltage at which the model was tested. R N Enumeration Data
  • 12 AC
  • 12 DC
  • 24 AC
  • 24 DC
  • 120
  • 240
  • 277
Reported Voltage (V) Provide the rated/reported voltage(s). R Y Enumeration Data
  • 12 AC
  • 12 DC
  • 24 AC
  • 24 DC
  • 120
  • 240
  • 277
Multiple Discrete Light Output Levels Indicate if the model has multiple distinct light output levels (e.g. 3-way). For multiple output lamps, provide performance information at the highest output level throughout the template. R N Enumeration Data
  • Yes
  • No
Measured Input Power (W) Provide the measured input power of the model based on test data. For color tunable lamps, provide the measured input power at the most consumptive white light setting. R N Decimal No. of Decimal: 1
Min Value: 0.0
Default Setting Input Power (W) Required for color tunable lamps only. Provide the measured input power at the default setting. O N Decimal No. of Decimal: 1
Reported Input Power (W) Provide the rated/reported lamp input power of the model, which will appear on the list of ENERGY STAR certified products. This value is required to be the same as measured or more conservative (more consumptive) as permitted for the purposes of safety ratings. Note that reported light output divided by reported wattage must meet the specification requirements for efficacy. For color tunable lamps, provide the rated/reported lamp input power at the most consumptive white light setting. R N Decimal No. of Decimal: 1
Min Value: 0.0
Claimed Wattage Equivalency Required if the model makes wattage equivalency claims to a standard incandescent. Per section 9.2. O N Integer Min Value: 0
Lamp Shape Equivalency Provide the lamp shape that the manufacturer is claiming equivalency to. For decorative products where no ANSI maximum lamp space drawing exists, choose the closest nominal lamp diameter (i.e., within 15% of the lamp maximum outside diameter) from this list. R N Enumeration Data
  • A15
  • A17
  • A19
  • A21
  • A23
  • C7
  • C9
  • C11
  • CA9
  • CA10
  • B10
  • B11
  • BA10
  • BA11
  • B13
  • F10
  • F15
  • F20
  • G16.5
  • G25
  • G30
  • G40
  • P25
  • PS25
  • PS30
  • PS35
  • PS40
  • S6
  • S11
  • S14
  • ST
  • ST12
  • ST15
  • ST18
  • ST19
  • ST20
  • T8
  • T10
  • CFL Bare Spiral
  • CFL Bare Other
  • CFL Candle
  • CFL Globe
  • CFL A-type
  • CFL Covered Other
Decorative Lamp Shape Equivalency Other If the precise lamp shape/size combination for the model was not included in the Lamp Shape Equivalency field options, provide actual ANSI lamp shape/size combination. O N Text Max Length: 1000
Maximum Overall Length (mm) Provide the maximum overall length of the model tested in millimeters. R N Decimal No. of Decimal: 1
Min Value: 0.0
Maximum Overall Diameter (mm) Provide the maximum overall diameter of the model tested in millimeters. R N Decimal No. of Decimal: 1
Min Value: 0.0
Frequency (Hz) Provide the average frequency based on test data. R N Integer Min Value: 120
Start Time (ms) Provide the average start time, in milliseconds, based on test data. R N Integer Max Value: 1000
CFL: Covered/Bare Tube Required for CFL lamps. Indicate whether the lamp has an envelope over the light source or not. O N Enumeration Data
  • Covered
  • Bare Tube
CFL: Mercury Content (mg) Required for CFL lamps. Provide the manufacturer's claimed mercury content in mg of mercury in the tested model. O N Decimal No. of Decimal: 1
Max Value: 3.0
CFL: Run-Up Time to 80% (s) Required for CFL lamps. Provide the average measured run-up time, in seconds, of the model based on test data. O N Integer Max Value: 45
Measured Efficacy (lm/W) Provide the calculated value based on test data per supplemental testing guidance in section 9.1. R N Decimal No. of Decimal: 1
Min Value: 65.0
Reported Efficacy (lm/W) Provide the calculated value based on reported light output and reported input power. Note that reported light output divided by reported wattage must meet the specification requirements for efficacy. R N Decimal No. of Decimal: 1
Min Value: 65.0
Measured Light Output (lm) Provide the measured light output of the model based on test data. For color tunable lamps, provide the light output measured at the most consumptive white light setting. R N Decimal No. of Decimal: 1
Default Setting Source Output (lm) Required for color tunable lamps only. Provide the light output measured at the default setting. O N Decimal No. of Decimal: 1
Tolerance Applied to Light Output Indicate if a 3% tolerance has been applied to the measured luminous flux values used for lumen maintenance calculations. Note: a 3% tolerance may be applied to all measured luminous flux values (e.g., [luminous flux X 1.03]) except at the 0-hour measurement, if the calculated lumen maintenance value fails to meet the requirement without the tolerance. No other tolerances should be applied. R N Enumeration Data
  • Yes
  • No
Reported Light Output (lm) Reported light output per section 9.2 should be consistent with the value stated on the product packaging and will appear on the list of ENERGY STAR certified products. Values may be more conservative. Note that reported output divided by reported wattage must meet the specification requirements for efficacy. For color tunable lamps, provide the performance at the most consumptive white light setting. R N Integer Min Value: 0
Max Value: 6000
Rated Life (Hours) Provide claimed lifetime, in hours, supported by lumen maintenance and life testing. R N Integer Min Value: 10000
LED: Zonal Flux Percentage Required for solid state lamps. Indicate percentage, in decimal format, of total flux (zonal lumens) emitted in the zone of interest as defined in section 9.5 of the specification. O N Decimal No. of Decimal: 2
Min Value: 0.05
Nominal Correlated Color Temperature (CCT) Provide the nominal CCT which will appear on the list of ENERGY STAR certified products. For color tunable lamps, one CCT must be selected, and if capable of operating at more than one CCT, multi-select all applicable CCTs. R Y Enumeration Data
  • 2200K
  • 2500K
  • 2700K
  • 3000K
  • 3500K
  • 4000/4100K
  • 5000K
  • 6500K
Correlated Color Temperature (CCT) Provide the average CCT value based on test data. For color tunable lamps, provide the average CCT value for the most consumptive white light setting. R N Integer Min Value: 2136
Max Value: 7040
Correlated Color Temperature (CCT ) at Default Setting Required for color tunable lamps. Provide the measured CCT value for the default setting. O N Integer
Color Rendering Index (CRI) Provide the average CRI value based on test data. For color tunable lamps, provide the average CRI at the most consumptive white light setting. R N Integer Min Value: 80
Max Value: 100
Color Rendering Index (CRI) at Default Setting Required for color tunable lamps. Provide the average CRI at the default setting. O N Integer Min Value: 80
Max Value: 100
Color Rendering: Average R9 Provide the average R9 of the samples based on test data. For color tunable lamps, provide the average R9 of the samples at the most consumptive white light setting. R N Integer
Color Rendering: Average R9 at Default Setting Required for color tunable lamps. Provide the average R9 of the samples at the default setting. O N Integer
Color Rendering: Fidelity Index Provide the average Fidelity Index, Rf, based on test data. For color tunable lamps, provide the average Fidelity Index at the most consumptive white light setting. R N Integer
Color Rendering: Fidelity Index at Default Setting Required for color tunable lamps. Provide the average Fidelity Index, Rf, based on test data at the default setting. O N Integer
Color Rendering: Gamut Index Provide the average Gamut Index, Rg, based on test data. For color tunable lamps, provide the performance at the most consumptive white light setting. R N Integer
Color Rendering: Gamut Index at Default Setting Required for color tunable lamps. Provide the average Gamut Index, Rg, based on test data at the default setting. O N Integer
LED: Color Maintenance Required for solid state lamps. Provide the maximum change in chromaticity over tested time period. O N Decimal No. of Decimal: 3
Max Value: 0.007
CFL: Units Surviving at Rated Life Required for CFL lamps. Indicate the percentage of units, in decimal format, surviving life testing at rated life. O N Decimal No. of Decimal: 2
Min Value: 0.50
RCST: Number of Cycles Required for CFL lamps. Provide the number of cycles surviving rapid cycle stress testing. O N Integer Min Value: 5000
Power Factor Required for all lamps except lamps less than or equal to 5 watts. Provide the average power factor based on test data. O N Decimal No. of Decimal: 1
Minimum Starting or Operating Temperature (C) Provide the minimum starting or operating temperature for the model tested. R N Integer
Dimmable Indicate whether the model is marketed as dimmable or non-dimmable. R N Enumeration Data
  • Dimmable
  • Non-dimmable
Dimming: Maximum Light Output Required for models marketed as dimmable. Indicate the manufacturer reported light output on the maximum setting of a dimmer/control as a percentage of baseline light output when operated without a dimmer, in decimal format (i.e., use 0.95 for 95%). O N Decimal No. of Decimal: 2
Dimming: Claimed Minimum Light Output Required for models marketed as dimmable. Indicate the manufacturer reported minimum light output level as a percentage, in decimal format (i.e., use .85 for 85%). O N Decimal No. of Decimal: 2
Dimmer Compatibility Required for models marketed as dimmable. Indicate the type of dimmer used to determine compatibility. O Y Enumeration Data
  • Phase Cut
  • Non Phase Cut
  • NEMA SSL 7A
  • NEMA SSL 7B
Dimming - Flicker: Average Light Output Periodic Frequency (Hz) Required for models marketed as dimmable. Indicate the manufacturer reported average light output periodic frequency at baseline light output. O N Integer
Dimming - NEMA LED Dimming Compatibility Program Registration Required for models marketed as dimmable. Indicate whether the Brand Name is registered with the NEMA LED Dimming Compatibility Program. O N Enumeration Data
  • Yes
  • No
Dimming - Flicker: NEMA 77 Short Term Flicker Indicator (PsT) Required for models marketed as dimmable. Indicate the highest short term flicker indicator (PsT), in decimal format. O N Decimal No. of Decimal: 2
Dimming - Flicker: NEMA 77 Stroboscopic Visibility Measure (SVM) Required for models marketed as dimmable. Indicate the highest measured stroboscopic visibility measure (SVM), in decimal format. O N Decimal No. of Decimal: 2
Dimming - Flicker: ASSIST Flicker Perception Metric (Mp) Required for models marketed as dimmable. Indicate the highest measured ASSIST Flicker Perception Metric (Mp), in decimal format. O N Decimal No. of Decimal: 2
Dimming - Flicker: Percent Flicker Required for models marketed as dimmable. Indicate the highest measured percent flicker, in decimal format (i.e., use 0.95 for 95%). O N Decimal No. of Decimal: 2
Dimming - Flicker: Flicker Index Required for models marketed as dimmable. Indicate the highest measured flicker index. O N Decimal No. of Decimal: 2
Dimming - Audible Noise (dBa) Required for models marketed as dimmable. Indicate the manufacturer reported loudest measured sound level value of all lamp/dimmer combinations. O N Decimal No. of Decimal: 2
Standby Power Indicate whether the model consumes power in the off state. R N Enumeration Data
  • Yes
  • No
Standby Power Consumption (W) Required if standby mode power consumption is greater than zero. Provide measured power value. O N Decimal No. of Decimal: 2
Max Value: 0.50
Standby Power (Outside of the Lamp) Required for Connected (W) Required for any equipment (outside of the lamp) that is required for connectivity (e.g., gateways, hubs, and network controllers, excluding equipment typically found in the home such as a Wi-Fi router). O N Decimal No. of Decimal: 2
Connected Lamp Indicate whether the lamp meets the criteria to be recognized as connected. R N Enumeration Data
  • Yes
  • No
Communication Method Required if Connected Lamp is Yes. Select all that apply. O Y Enumeration Data
  • Wi-Fi
  • Zigbee
  • HomePlug Green PHY
  • 6LoWPAN
  • Z-Wave
  • Bluetooth
  • Other
Communication Method Other Required if Communication Standard - Media/Network Layer is Other. Indicate relevant standard(s). O N Text Max Length: 1000
Warranty (Years) R N Integer Min Value: 2
Lamp Rated for Enclosed Fixtures Indicate if the model is rated for use in enclosed fixtures by the manufacturer. Safety related fields must be consistent with lamp marking. R N Enumeration Data
  • Yes
  • No
Lamp Rated Applications/Features Indicate if the model is rated for use by the manufacturer. Safety related fields must be consistent with lamp marking. Additional features may be indicated. R Y Enumeration Data
  • Recessed Fixtures
  • Not for Use in Recessed Fixtures
  • Damp Location Rated
  • Wet Location Rated
  • Use With Photo and/or Motion Sensors
  • Use With Timers
  • Vibration Service
  • Shatter Resistant
  • Wireless Control
  • Dim to Warm
  • White-Tunable
  • Full-Color-Tunable
  • Filament Style
  • None
  • Other
Lamp Rated Applications Other Required if Lamp Rated Application is Other. Provide the lamp rated application(s). O N Text Max Length: 1000
Lamp Test Orientation Indicate if the model is listed as position restricted by the manufacturer. R N Enumeration Data
  • Universal - Not Position Restricted
  • Vertical - Base Up Only
  • Vertical - Base Down Only
  • Horizontal Only
Commercial/Residential Indicate if the model is intended to be sold for commercial applications, residential applications, or both. R Y Enumeration Data
  • Commercial
  • Residential
Additional Notes Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model's listing such as 3-way light levels, etc). O N Text Max Length: 1000

Information for certification bodies to provide to EPA on Non-Directional/Decorative Lamps certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Lamps V2.0 and V2.1. Additional instructions for submitting this information to EPA are available at www.energystar.gov/qpx.