ENERGY STAR Commercial Ovens Template

Service Method: Submit_Commercial_Ovens_2_x
Version Number: V2
Description: Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Commercial Ovens Version 2.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History Subscribe to updates via RSS 2.0:
  • 07/17/14 - Submit_Commercial_Ovens_2_x Updated
  • 06/14/13 - Submit_Commercial_Ovens_2_x Final
  • 05/30/13 - Submit_Commercial_Ovens_2_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Product Specific Information info
ENERGY STAR Specification Version R N Enumeration Data
  • 2.0
  • 2.1
Product Type R N Enumeration Data
  • Electric Convection Ovens
  • Gas Convection Ovens
  • Electric Combination Oven
  • Gas Combination Oven
Method of Steam Generation Required for combination ovens. O N Enumeration Data
  • Boiler
  • Boiler-less
Size R N Enumeration Data
  • Half-Size
  • Full-Size
Steam Pan Capacity Required for combination ovens. Provide the number of steam pans the oven can accommodate based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Integer Min Value: 1
Max Value: 40
Half-Size Sheet Pan Capacity Required for half-size convection ovens. Provide the number of half-size sheet pans the oven can accommodate based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Integer Min Value: 1
Max Value: 20
Full-Size Sheet Pan Capacity Required for full-size convection ovens. Provide the number of full-size sheet pans the oven can accommodate based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Integer Min Value: 1
Max Value: 20
Heat Source Fuel-Type R N Enumeration Data
  • Gas
  • Electric
Door Type R N Enumeration Data
  • Glass
  • Solid
  • Glass/Solid
Additional Door Types Provide additional door types. Indicate N/A if no additional door types. R N Enumeration Data
  • Glass
  • Solid
  • Glass/Solid
  • N/A
Voltage (V) Required for electric ovens. Provide the value based on measured test data. O N Integer Min Value: 100
Electric Oven Input Rate (kW) Required for electric ovens. Provide the value based on measured test data. O N Decimal No. of Decimal: 2
Gas Oven Input Rate (Btu/h) Required for gas ovens. Provide the value based on measured test data. O N Integer
Gas Oven Convection Mode Pre-Heat Energy (Btu) Required for gas ovens. Provide the calculated pre-heat energy value based on measured test data. O N Integer
Convection Mode Pre-Heat Time (min) Required for convection and combination ovens. Provide the pre-heat time value based on measured test data. O N Decimal No. of Decimal: 2
Electric Oven Convection Mode Pre-Heat Energy (kWh) Required for electric ovens. Provide the calculated pre-heat energy value based on measured test data. O N Integer
Gas Oven Convection Mode Idle Energy Rate (Btu/h) Required for gas ovens. Provide the calculated gas oven convection mode idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Integer
Electric Oven Convection Mode Idle Energy Rate (kW) Required for electric ovens. Provide the calculated electric oven convection mode idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Gas Oven Convection Mode Electric Idle Energy Rate (kW) Required for gas ovens. Provide the calculated gas oven convection mode electric idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Gas Oven Convection Mode Total Idle Energy Rate (Btu/h) Required for gas ovens. Provide the calculated gas oven convection mode total idle energy rate value based on measured test data. O N Integer
Gas Oven Steam Mode Pre-Heat Energy (Btu) Required for gas combination ovens. Provide the calculated pre-heat energy value based on measured test data. O N Integer
Steam Mode Pre-Heat Time (min) Required for combination ovens. Provide the calculated pre-heat time value based on measured test data. O N Decimal No. of Decimal: 2
Electric Oven Steam Mode Pre-Heat Energy (kWh) Required for electric combination ovens. Provide the calculated pre-heat energy value based on measured test data. O N Integer
Convection Mode Average Idle Rate Temperature (°F) Provide the calculated convection mode average idle rate temperature value based on measured test data. R N Decimal No. of Decimal: 2
Min Value: 345
Max Value: 355
Gas Oven Steam Mode Idle Energy Rate (Btu/h) Required for gas combination ovens. Provide the calculated gas oven steam mode idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Integer
Electric Oven Steam Mode Idle Energy Rate (kW) Required for electric combination ovens. Provide the calculated electric oven steam mode idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Gas Oven Steam Mode Electric Idle Energy Rate (kW) Required for gas combination ovens. Provide the calculated gas oven steam mode electric idle energy rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Gas Oven Steam Mode Total Idle Energy Rate (Btu/h) Required for gas combination ovens. Provide the calculated gas oven convection mode total idle energy rate value based on measured test data. O N Integer
Steam Mode Average Idle Rate Temperature (°F) Required for combination ovens. Provide the calculated steam mode average idle rate temperature value based on measured test data. O N Decimal No. of Decimal: 2
Convection Mode Cooking-Energy Efficiency (%) Provide the calculated convection mode cooking-energy efficiency value based on measured test data, which will appear on the ENERGY STAR list of qualified products. R N Decimal No. of Decimal: 2
Max Value: 1
Convection Mode Production Capacity (lbs/h) Provide the calculated convection mode cooking-energy efficiency production capacity value based on measured test data, which will appear on the ENERGY STAR list of qualified products. R N Decimal No. of Decimal: 2
Convection Mode Average Water Consumption Rate (gal/h) Required for combination ovens. Provide the calculated convection mode cooking-energy efficiency average water consumption rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Convection Mode Average Condensate Drain Temperature (°F) Required for combination ovens. Provide the calculated convection mode cooking-energy efficiency average condensate drain temperature value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Convection Mode Max Condensate Drain Temperature (°F) Required for combination ovens. Provide the calculated convection mode cooking-energy efficiency test's maximum condensate drain temperature value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Steam Mode Cooking-Energy Efficiency (%) Required for combination ovens. Provide the calculated steam mode cooking-energy efficiency value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Max Value: 1
Steam Mode Production Capacity (lbs/h) Required for combination ovens. Provide the calculated steam mode cooking-energy efficiency production capacity value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Steam Mode Average Water Consumption Rate (gal/h) Required for combination ovens. Provide the calculated steam mode cooking-energy efficiency average water consumption rate value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Min Value: 0.01
Steam Mode Average Condensate Drain Temperature (°F) Required for combination ovens. Provide the calculated steam mode cooking-energy efficiency average condensate drain temperature value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2
Steam Mode Maximum Condensate Drain Temperature (°F) Required for combination ovens. Provide the calculated steam mode cooking-energy efficiency maximum condensate drain temperature value based on measured test data, which will appear on the ENERGY STAR list of qualified products. O N Decimal No. of Decimal: 2

Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Commercial Ovens Version 2.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.