ENERGY STAR Imaging Equipment Template

Service Method: Submit_Imaging_Equipment_2_x
Version Number: V2
Description: Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Imaging Equipment Version 2.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History Subscribe to updates via RSS 2.0:
  • 06/14/13 - Submit_Imaging_Equipment_2_x Final
  • 05/30/13 - Submit_Imaging_Equipment_2_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Product Specific Information info
ENERGY STAR Specification Version R N Enumeration Data
  • 2.0
Product Type R N Enumeration Data
  • Copiers
  • Digital Duplicators
  • Fax Machines
  • MFDs
  • Mailing Machines
  • Printers
  • Scanners
Sold at Retail? R N Enumeration Data
  • Yes
  • No
Standard Accessories/Capabilities R Y Enumeration Data
  • Anti-humidity Device
  • Caller ID
  • Combine-imaging
  • Document Feeder
  • PC scan-print Capability
  • PCL 4
  • PCL 5
  • PCL 6
  • PostScript
  • PPDS
  • Common Access Card Reader (Magnetic)
  • Common Access Card Reader (RFID)
  • Voice Recognition
  • Wired < 20 MHz - IEEE 1284/Parallel/Centronics
  • Wired < 20 MHz - Other
  • Wired < 20 MHz - RS232
  • Wired < 20 MHz - USB 1.x
  • Wired > 20 MHz and < 500 MHz - 100/10 Mb/s Ethernet
  • Wired > 20 MHz and < 500 MHz - Other
  • Wired > 20 MHz and < 500 MHz - USB 2.x
  • Wired > 500 MHz - 1 Gb/s Ethernet
  • Wired > 500 MHz - USB 3.x
  • Wired > 500 MHz - Other
  • Fax Modem
  • Wireless - WiFi
  • Wireless - Other
  • None
  • Other
Standard Accessories/Capabilities Other Required if Standard Accessories/Capabilities is Other. Provide the standard accessory/accessories or capability/capabilities. O N Text Max Length: 1000
Optional Accessories/Capabilities R Y Enumeration Data
  • Anti-humidity Device
  • Caller ID
  • Combine-imaging
  • Document Feeder
  • PC scan-print Capability
  • PCL 4
  • PCL 5
  • PCL 6
  • PostScript
  • PPDS
  • Common Access Card Reader (Magnetic)
  • Common Access Card Reader (RFID)
  • Voice Recognition
  • Wired < 20 MHz - IEEE 1284/Parallel/Centronics
  • Wired < 20 MHz - Other
  • Wired < 20 MHz - RS232
  • Wired < 20 MHz - USB 1.x
  • Wired > 20 MHz and < 500 MHz - 100/10 Mb/s Ethernet
  • Wired > 20 MHz and < 500 MHz - Other
  • Wired > 20 MHz and < 500 MHz - USB 2.x
  • Wired > 500 MHz - 1 Gb/s Ethernet
  • Wired > 500 MHz - USB 3.x
  • Wired > 500 MHz - Other
  • Fax Modem
  • Wireless - WiFi
  • Wireless - Other
  • None
  • Other
Optional Accessories/Capabilities Other Required if Optional Accessories/Capabilities is Other. Provide the optional accessory/accessories or capability/capabilities. O N Text Max Length: 1000
Additional Cordless Handset Indicate whether the model is shipped with an additional cordless handset. R N Enumeration Data
  • Yes
  • No
Additional Cordless Handset Manufacturer Name Required for models shipped with Additional Cordless Handset. Provide the additional cordless handset manufacturer name. O N Text Max Length: 255
Additional Cordless Handset Model Number Required for models shipped with Additional Cordless Handset. Provide the additional cordless handset model number. O N Text Max Length: 255
Additional Cordless Handset ENERGY STAR Qualification Required for models shipped with Additional Cordless Handset. Indicate whether additional cordless handset is ENERGY STAR qualified or not ENERGY STAR qualified. O N Enumeration Data
  • Yes
  • No
Is This Product Shipped With an External Power Supply (EPS)? R N Enumeration Data
  • Yes
  • No
Type of EPS Required for models shipped with an EPS or models using an EPS with a Digital Front End (DFE). Indicate the type of EPS power supply. O N Enumeration Data
  • Ac-Ac
  • Ac-Dc
Power Source Provide all power sources compatible with the model. R Y Enumeration Data
  • Ac Power
  • USB
  • Power Over Ethernet (PoE)
  • USB Plus Power
  • IEEE 1394
  • Other
Power Source Other Required if the Power Source is Other. Provide the Power Source. O N Text Max Length: 1000
Is the Model Shipped with One or More Digital Front Ends (DFEs)? Indicate whether the model is shipped with one or more DFE(s). R N Enumeration Data
  • Yes
  • No
DFE Type and Category Required for models shipped with a DFE. If sold with a Type 2 DFE, indicate the category of the Type 2 DFE. Additionally, if sold with a Type 1 DFE, indicate the category of the Type 1 DFE. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. (The categories of the other Type 1 DFEs are to be reported in another field). O Y Enumeration Data
  • Type 1 - Category A
  • Type 1 - Category B
  • Type 2 - Category A
  • Type 2 - Category B
Type 1 DFE Advanced Features Required for models shipped with a DFE. Indicate three or more DFE advanced features. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O Y Enumeration Data
  • Network Connectivity in Various Environments
  • Mailbox Functionality
  • Job Queue Management
  • Machine Management
  • Advanced Graphic User-interface
  • Ability to Initiate Communication with Host Servers and Client Computers
  • Ability to Post-process Pages
Type 1 DFE Manufacturer Name Required for models shipped with a Type 1 DFE. Indicate the DFE manufacturer name. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O N Text Max Length: 255
Type 1 DFE Model Number Required for models shipped with a Type 1 DFE. Indicate the DFE model number. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O N Text Max Length: 255
Type 1 DFE TEC (kWh/wk) Required for models with a Type 1 DFE. Provide the DFE TEC in kWh per week. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 22.7
Type 1 DFE Sleep Mode Power (W) Required for models with a Type 1 DFE. Indicate the DFE Sleep Mode power in watts. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 185
Type 1 DFE Ready State Power (W) Required for models with a Type 1 DFE. Indicate the DFE Ready State power in watts. For models sold with multiple Type 1 DFEs, indicate the category of the Type 1 DFE that constitutes the highest energy using configuration. O N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 505
Type 2 DFE Advanced Features Required for models shipped with a Type 2 DFE. Indicate three or more DFE advanced features. O Y Enumeration Data
  • Network Connectivity in Various Environments
  • Mailbox Functionality
  • Job Queue Management
  • Machine Management
  • Advanced Graphic User-interface
  • Ability to Initiate Communication with Host Servers and Client Computers
  • Ability to Post-process Pages
Type 2 DFE Manufacturer Name Required for models shipped with a Type 2 DFE. Indicate the DFE manufacturer name. O N Text Min Length: 0
Max Length: 255
Type 2 DFE Model Number Required for models shipped with a Type 2 DFE. Indicate the DFE model number. For Type 2 DFEs without their own model number, enter "No separate model number." O N Text Min Length: 0
Max Length: 255
Type 2 DFE TEC (kWh/wk) Required for models with a Type 2 DFE. Provide the DFE TEC in kWh per week. O N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 18.2
Type 2 DFE Sleep Mode Power (W) Required for models with a Type 2 DFE. Indicate the DFE Sleep Mode power in watts. O N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 148
Type 2 DFE Ready State Power (W) Required for models with a Type 2 DFE. Indicate the DFE Ready State power in watts. O N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 405
Additional Type 1 DFE Category(ies) Required for models sold with more than one Type 1 DFE option. Indicate the Type 1 DFE category (A or B). For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : < Category of DFE #2>, etc.” O N Text Max Length: 1000
Additional Type 1 DFE Manufacturer Name(s) Required for models sold with more than one Type 1 DFE option. Indicate the Type 1 DFE manufacturer name. For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : , etc.” O N Text Max Length: 1000
Additional Type 1 DFE Model Number(s) Required for models sold with more than one Type 1 DFE option. Indicate the Type 1 DFE model number. For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : , etc.” O N Text Max Length: 1000
Additional Type 1 DFE TEC(s) (kWh/wk) Required for models sold with more than one Type 1 DFE option. Provide the DFE TEC in kWh per week. For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : , etc.” O N Text Max Length: 1000
Additional Type 1 DFE Sleep Mode Power(s) (W) Required for models sold with more than one Type 1 DFE option. Indicate the Sleep Mode power in W. For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : < Sleep Mode Power of DFE #2>, etc.” O N Text Max Length: 1000
Additional Type 1 DFE Ready State Power(s) (W) Required for models sold with more than one Type 1 DFE option. Indicate the Ready State power in W. For multiple additional Type 1 DFE models, enter data in the following comma-separated list format: “1 : , 2 : , etc.” O N Text Max Length: 1000
Media Format Size R N Enumeration Data
  • Small
  • Standard
  • Large
Continuous Form? R N Enumeration Data
  • Yes
  • No
Maximum Document Width (mm) Provide the smaller of the two document dimensions here. R N Integer
Maximum Document Height (mm) Required for products that are not Continuous Form. Provide the larger of the two document dimensions here. O N Integer
Simplex Printing Minimum Paper Weight (Density) Compatibility (g/m^2) Required for products with print functionality. Indicate the simplex printing minimum paper weight (density) compatibility in grams per square meter. O N Integer
Duplex Printing Minimum Paper Weight (Density) Compatibility (g/m^2) Required for products with print functionality. Indicate the duplex printing minimum paper weight (density) compatibility in grams per square meter. O N Integer
Simplex Printing Maximum Paper Weight (Density) Compatibility (g/m^2) Required for products with print functionality. Indicate the simplex printing maximum paper weight (density) compatibility in grams per square meter. O N Integer
Duplex Printing Maximum Paper Weight (Density) Compatibility (g/m^2) Required for products with print functionality. Indicate the duplex printing maximum paper weight (density) compatibility in grams per square meter. O N Integer
Marking Technology R N Enumeration Data
  • Direct Thermal (DT)
  • Dye Sublimation (DS)
  • Electro-photographic (EP)
  • Impact
  • Ink Jet (IJ)
  • High Performance IJ
  • Solid Ink (SI)
  • Stencil
  • Thermal Transfer (TT)
  • N/A (Scanner)
Product Functions Required for MFD or digital duplicator models. Indicate the product functions standard for these models. O Y Enumeration Data
  • Copying
  • Printing
  • Scanning
  • Faxing
Optional Functions Required for MFD or digital duplicator models. List the optional functions available for upgrade. O Y Enumeration Data
  • Copying
  • Printing
  • Scanning
  • Faxing
  • None
Automatic Duplex Output Capability R N Enumeration Data
  • Yes
  • No
  • Optional
Special Purpose Single Sided Printer Is the model a printer whose intended function is to print on special single-sided media for the purpose of single sided printing (e.g. release coated paper for labels, direct thermal media, etc.)? R Y Enumeration Data
  • Yes
  • No
Default to Automatic Duplex Output Capability Required for models with automatic duplex output capability. Indicate whether the model is shipped with automatic duplexing as the default mode. O N Enumeration Data
  • Yes
  • No
Color Capability Required for products with print functionality. Indicate the color capability. O N Enumeration Data
  • Color
  • Monochrome
Monochrome Product Speed (ipm or mppm) For mailing machines, provide the monochrome product speed in units of mail-pieces-per-minute (mppm). For all other product types, provide the monochrome product speed in images-per-minute (ipm). R N Integer Min Value: 1
Color Product Speed (ipm or mppm) Required for models with color capability. For mailing machines, provide the color product speed in units of mail-pieces-per-minute (mppm). For all other product types, provide the color product speed in images-per-minute (ipm). O N Integer Min Value: 1
Type of Multifunction Device (MFD) Required for MFD models. Provide the type of MFD. O N Enumeration Data
  • Physically Integrated
  • Functionally Integrated But Physically Separate
Scan Functionality Indicate whether scan functionality is included in the Product Model. R N Enumeration Data
  • Yes
  • No
Scanner Feed Method Required for models with scan functionality. Indicate the scanner feed method. O Y Enumeration Data
  • Flatbed
  • Microfilm
  • Sheet Fed
Fax Functionality Indicate whether fax functionality is included in the Product Model. R N Enumeration Data
  • Yes
  • No
Fax Modem Speed (bps) Required for models with fax functionality. Indicate the fax modem speed in bits per second (bps). O N Integer
Internal Memory (MB) Required for models claiming a functional adder allowance for memory. Provide the memory in megabits (MB). O N Integer
Default Delay Time to Sleep (min) Provide the default delay time to sleep in minutes. R N Integer Min Value: 0
Default Delay Time to Off (min) Required for models subject to OM ENERGY STAR evaluation method and with an Auto-off mode. Provide the default delay time to off in minutes. O N Integer Min Value: 0
Additional Sleep Modes? Indicate if there are additional sleep modes other than the sleep mode used to determine qualification under the default delay time to sleep requirements. R N Enumeration Data
  • Yes
  • No
Additional Sleep Mode Name(s) Required if additional sleep modes are claimed other than the sleep mode used to determine qualification under the default delay time to sleep requirements. Provide the name(s) of the mode(s). O N Text Max Length: 1000
Default Delay Time to Sleep for Additional Sleep Modes (min) Required for models with additional sleep modes other than the sleep mode used to determine qualification under the default delay time to sleep requirements. Indicate the default time to sleep in minutes for one of the additional sleep modes. O N Integer Min Value: 1
Max Value: 60
Network or Data Connection(s) as Tested R N Enumeration Data
  • No Network Connection
  • Wi-Fi
  • 1 Gb/s Ethernet
  • 100/10 Mb/s Ethernet
  • IEEE 1284/Parallel/Centronics
  • RS232
  • USB 1.x
  • USB 2.x
  • USB 3.x
  • Other
Network or Data Connection(s) as Tested Other Required if the Network Connection(s) as Tested is Other. Provide the Network Connection(s) as Tested. O N Text Max Length: 1000
Interface Functional Adders Indicate no more than two Interface Functional Adders. If zero Interface Functional Adders are included, indicate None. R Y Enumeration Data
  • None
  • Wired < 20 MHz - IEEE 1284/Parallel/Centronics
  • Wired < 20 MHz - Other
  • Wired < 20 MHz - RS232
  • Wired < 20 MHz - USB 1.x
  • Wired > 20 MHz and < 500 MHz - 100/10 Mb/s Ethernet
  • Wired > 20 MHz and < 500 MHz - Other
  • Wired > 20 MHz and < 500 MHz - USB 2.x
  • Wired > 500 MHz - 1 Gb/s Ethernet
  • Wired > 500 MHz - USB 3.x
  • Wired > 500 MHz - Other
  • Fax Modem
  • Wireless - WiFi
  • Wireless - Other
  • Other
Non-interface Functional Adders Indicate as many Non-interface Functional Adders as present. If zero Non-interface Functional Adders are included, indicate None. Scanner lamp adders apply only to MFDs and Copiers, not Scanners. R Y Enumeration Data
  • None
  • Cordless Handset
  • Memory
  • Touch Panel Display - Monochrome
  • Touch Panel Display - Color
  • Power-supply Size > 10W
  • Scanners with CCFL Lamps
  • Scanners with non-CCFL Lamps - Halogen
  • Scanners with non-CCFL Lamps - Hot Cathode Fluorescent Tube (HCFT)
  • Scanners with non-CCFL Lamps - Light-Emitting Diodes (LED)
  • Scanners with non-CCFL Lamps - Tubular Fluorescent (TL)
  • Scanners with non-CCFL Lamps - Xenon
  • Scanners with non-CCFL Lamps - Other
  • Internal Disk Drive - Hard-Disk
  • Internal Disk Drive - Solid-State
  • Internal Disk Drive - Other
  • Other
Power Supply Rated Output Power (W) Provide the power supply rated output power in watts. Enter 0 for Dc-powered models with no power supply. Required for all products, even if not claiming an OM power supply adder allowance. R N Integer Min Value: 0
Step 1: "Off Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Off Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Min Value: 0
Step 1: "Off Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Off Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Min Value: 0
Step 1: "Off Interval" at 115 V Time (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Off Interval Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 1: "Off Interval" at 230 V Time (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Off Interval Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Step 3: "Active0" Time at 115 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active0 Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 3: "Active0" Time at 230 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active0 Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Step 5: "Sleep Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Sleep Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 5: "Sleep Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Sleep Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 6: "Job1 Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job1 Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 6: "Job1 Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job1 Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 6: "Active1" Time at 115 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active1 Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 6: "Active1" Time at 230 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active1 Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Step 7: "Job2 Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job2 Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 7: "Job2 Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job2 Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 7: "Active2" Time at 115 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active2 Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 7: "Active2" Time at 230 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Active2 Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Step 8: "Job3 Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job3 Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 8: "Job3 Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job3 Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 9: "Job4 Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job4 Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 9: "Job4 Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job4 Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 10: "Final Interval" Energy at 115 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job4 Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 10: "Final Interval" Energy at 230 V (Wh) Required for models subject to TEC ENERGY STAR evaluation method. Provide Job4 Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 10: "Final Interval" Time at 115 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Final Interval Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 10: "Final Interval" Time at 230 V (min) Required for models subject to TEC ENERGY STAR evaluation method. Provide the Final Interval Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Step 11: "Auto-off Interval" Energy at 115 V (Wh) Required for copiers, digital duplicators without print capability, and MFDs without print capability subject to TEC ENERGY STAR evaluation method. Provide Auto-off Interval Energy at 115 V in Wh. O N Decimal No. of Decimal: 1
Step 11: "Auto-off Interval" Energy at 230 V (Wh) Required for copiers, digital duplicators without print capability, and MFDs without print capability subject to TEC ENERGY STAR evaluation method. Provide Auto-off Interval Energy at 230 V in Wh. O N Decimal No. of Decimal: 1
Step 11: "Auto-off Interval" Time at 115 V (min) Required for copiers, digital duplicators without print capability, and MFDs without print capability subject to TEC ENERGY STAR evaluation method. Provide the Auto-off Interval Time at 115 V in minutes. O N Decimal No. of Decimal: 2
Step 11: "Auto-off Interval" Time at 230 V (min) Required for copiers, digital duplicators without print capability, and MFDs without print capability subject to TEC ENERGY STAR evaluation method. Provide the Auto-off Interval Time at 230 V in minutes. O N Decimal No. of Decimal: 2
Typical Energy Consumption (TEC) at 115 V (kWh/wk) Required for models subject to TEC ENERGY STAR evaluation method. Provide TEC at 115 V in kWh per week. O N Decimal No. of Decimal: 3
Typical Energy Consumption (TEC) at 230 V (kWh/wk) Required for models subject to TEC ENERGY STAR evaluation method. Provide TEC at 230 V in kWh per week. O N Decimal No. of Decimal: 3
Ready Power at 115 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide ready power at 115 V in W. O N Decimal No. of Decimal: 2
Ready Power at 230 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide ready power at 230 V in W. O N Decimal No. of Decimal: 2
Min Value: 0
Sleep Power at 115 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide sleep power at 115 V in W. O N Decimal No. of Decimal: 2
Sleep Power at 230 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide sleep power at 230 V in W. O N Decimal No. of Decimal: 2
Auto-off Power at 115 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide auto-off power at 115 V in W. O N Decimal No. of Decimal: 2
Auto-off Power at 230 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide auto-off power at 230 V in W. O N Decimal No. of Decimal: 2
Off Power at 115 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide off power at 115 V in W. O N Decimal No. of Decimal: 2
Off Power at 230 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide off power at 230 V in W. O N Decimal No. of Decimal: 2
Standby Power at 115 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide standby power at 115 V in W. O N Decimal No. of Decimal: 2
Min Value: 0
Max Value: 0.5
Standby Power at 230 V (W) Required for models subject to OM ENERGY STAR evaluation method. Provide standby power at 230 V in W. O N Decimal No. of Decimal: 2
Min Value: 0
Max Value: 0.5

Information for certification bodies to provide to EPA on products certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Imaging Equipment Version 2.0. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.