ENERGY STAR Outdoor Non-Directional Luminaires Template

Service Method: Submit_Outdoor_Non_Directional_Luminaires_1_x
Version Number: V1 Outdoor Non-directional
Description: Information for certification bodies to provide to EPA on Outdoor Non-Directional Luminaires certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 1.1 or Version 1.2. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History Subscribe to updates via RSS 2.0:
  • 11/14/12 - Submit_Outdoor_Non_Directional_Luminaire_1_x Final
  • 10/02/12 - Submit_Outdoor_Non_Directional_Luminaire_1_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
Outdoor_Non_Directional_Luminaires info
ENERGY STAR Specification Version R N Enumeration Data
  • 1.1
  • 1.2
Product Type R N Enumeration Data
  • Outdoor Non-Directional Luminaire
Indoor/Outdoor Indicate whether the luminaire is intended for outdoor use. R N Enumeration Data
  • Outdoor Luminaire
Qualification Status Indicate whether the light source has achieved conditional qualification (testing at 40% of rated life) or full qualification. R N Enumeration Data
  • Conditional Qualification
  • Full Qualification
Date Fully Qualified Required for models with a fully qualified listing status. Provide the date the light source achieved full qualification. O N Date
Tested Voltage (V) Provide the voltage(s) at which the model was tested. R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Reported Voltage (V) Provide the rated/reported voltage(s). R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Lighting Technology R N Enumeration Data
  • LED
  • Fluorescent
  • Halogen
  • HID
Source Type Indicate one of the allowable source types. R N Enumeration Data
  • Self-ballasted CFL (GU24)
  • Compact Fluorescent
  • Linear Fluorescent
  • Circline
  • Halogen
  • High Pressure Sodium
  • Metal Halide
  • Ceramic Metal Halide
  • GU24 Based Integrated LED Lamp
  • LED Light Engine
Residential Non-Directional Luminaire Type Indicate one of the luminaire types. R N Enumeration Data
  • Ceiling Mount
  • Close to Ceiling Mount
  • Porch (wall mounted)
  • Pendant
  • Security
  • Other
Luminaire Description Required if luminaire type is Other. O N Text Max Length: 1000
Light Source Manufacturer If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". R N Text Min Length: 1
Max Length: 1000
Light Source Model Number If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". R N Text Min Length: 1
Max Length: 1000
Light Source is Self-ballasted or has Integrated Driver If the light source is removable and is integrated with a power supply such as a driver or ballast, indicate Yes. If the light sources is removable but requires a separate power supply, indicate No. R N Enumeration Data
  • Yes
  • No
Light Source Shipped with Fixture No is only allowable when the luminaire is exempt from shipping a lamp with the fixture. R N Enumeration Data
  • Yes
  • No
ANSI-IEC Standardized Lamp Shape Provide the lamp shape for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines. R N Enumeration Data
  • A15
  • A17
  • A19
  • A21
  • A23
  • C7
  • C9
  • CA9
  • CA10
  • B10
  • BA10
  • B13
  • F10
  • F15
  • F20
  • S11
  • S14
  • PS25
  • PS30
  • PS35
  • G16.5
  • G25
  • G30
  • G40
  • ER30
  • ER40
  • R14
  • R16
  • R20
  • R30
  • R40
  • BR30
  • BR38
  • BR40
  • PAR14
  • PAR16
  • PAR20
  • PAR30
  • PAR30L
  • PAR38
  • MR8
  • MR11
  • MR16
  • T5
  • T6
  • T7
  • T8
  • T10
  • T12
  • Twin T4
  • Twin T5
  • Quad T4
  • Quad T5
  • Square T4
  • Square T6
  • Circular T5
  • Circular T9
  • Circular T10
  • Multi T4
  • Multi T5
  • U-Bend T8
  • U-Bend T12
  • ED17
  • ED18
  • ED28
  • BT28
  • Other
  • N/A
ANSI-IEC Designated Lamp Base Type Required for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines. R N Enumeration Data
  • E11
  • E12
  • E17
  • E26
  • E39
  • EX39
  • BA15S
  • BA15D
  • G4
  • GU4
  • G5
  • GU5.3
  • GY5.3
  • GY6.35
  • 2G7
  • 2GX7
  • 2G8
  • G9
  • G10q
  • GU10
  • 2G11
  • G13
  • 2G13
  • 2GX13
  • G23
  • G23-2
  • GU24
  • GX23
  • GX23-2
  • G24D
  • G24q
  • GX24q
  • GX24Xd
  • G32D
  • GX32D
  • GY32D
  • G32Q
  • GX32q
  • GX53
  • R17D
  • R7S
  • RX7s
  • G12
  • GX10
  • G8.5
  • GU6.5
  • Other
  • N/A
Number of Light Sources per Ballast/Driver R N Integer
Number of Light Sources per Luminaire R N Integer
Number of Ballasts/Drivers per Luminaire R N Integer
External Ballast/Driver Manufacturer Required for luminaires utilizing an external power supply. Provide the name of ballast, transformer, or driver manufacturer. Not required for luminaires utilizing LED light engines, GU24 based integrated lamps, or halogen luminaires. O N Text Max Length: 1000
External Ballast/Driver Model Number Required for luminaires utilizing an external power supply. Provide the ballast, transformer, or driver model number. Not required for luminaires utilizing LED light engines, GU24 based integrated lamps, or halogen luminaires O N Text Max Length: 1000
Claimed Incandescent Equivalency (W) Required for models that include equivalency claims on packaging. O N Integer Min Value: 0
Measured Input Power (W) Provide the measured input power of the model based on test data. R N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
Reported Input Power (W) Provide the rated/reported lamp input power of the model, which will appear on the list of ENERGY STAR qualified products. R N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
Source Luminous Efficacy (lm/W) Halogen luminaires exempt. Provide the calculated value based on test data. O N Decimal No. of Decimal: 1
Min Value: 40.0
Reported Source Light Output (lm) Halogen luminaires exempt. This should be consistent with the value stated on the product packaging and will appear on the list of ENERGY STAR qualified products. O N Integer Min Value: 800
Measured Source Light Output (lm) Not required for halogen luminaires. Provide the measured light output of the model based on test data. O N Integer Min Value: 800
Lumen Output of Single Light Source (lm) If there are multiple lumen output values, separate each by a backslash. R N Text Min Length: 1
Max Length: 1000
Wattage of Individual Light Source (W) List the light source wattage(s) used in the luminaire. If there are multiple wattages used, separate each by a backslash. R N Text Min Length: 1
Max Length: 1000
Light Source Life (hours) R N Integer Min Value: 2500
Average Lumen Maintenance at 40% of Lamp Life Required for fluorescent and HID lamps. O N Decimal No. of Decimal: 2
Min Value: 0.80
Max Value: 1.00
Solid State Option 1: LM-80 and TM-21 Projected Time to L70 Required for luminaires using Solid State Option 1 to satisfy lumen maintenance requirements. Indicate "Reported Lumen Maintenance Life" in hours as determined by EPA provided TM-21 calculator (hours). O N Integer Min Value: 35000
Solid State Option 2: Average Lumen Maintenance at 6,000 Hours Required for luminaires using Solid State Option 2 to satisfy lumen maintenance requirements. Provide value in decimal format (i.e., use .918 for 91.8%). O N Decimal No. of Decimal: 3
Min Value: 0.918
Nominal Correlated Color Temperature (CCT) Provide the nominal CCT which will appear on the list of ENERGY STAR qualified products. O N Enumeration Data
  • 2700K
  • 3000K
  • 3500K
  • 4000/4100K
  • 5000K
  • Other
Amalgam/Non-Amalgam Required for models containing mercury. Indicate N/A for other light sources. R N Enumeration Data
  • Amalgam
  • Non-Amalgam
  • N/A
Mercury Content (mg) Required for models containing mercury. Indicate the amount of mercury (in mg) the model contains. O N Decimal No. of Decimal: 1
Dimmable Indicate which dimming mechanism is used or select non-dimmable if luminaire is not capable of dimming. R N Enumeration Data
  • Non-Dimmable
  • Continuous Dimming
  • Step Dimming
Meets Photo Sensor Requirement Required for halogen luminaires only. O N Enumeration Data
  • Yes
  • No
Meets Motion Sensor Requirement Required for halogen luminaires only. O N Enumeration Data
  • Yes
  • No
Power Factor Halogen luminaires exempt. Provide the average power factor based on test data. O N Decimal No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00
Current Crest Factor Required for discharge lamps (non-self ballasted Fluorescent and HID) only. Provide lamp current crest factor based on test data. O N Decimal No. of Decimal: 1
Max Value: 1.8
Off-state Power Indicate whether the model consumes power in the off-state. R N Enumeration Data
  • Yes
  • No
Off-state Power Consumption (W) Required if off-state power consumption is greater than zero. O N Integer
Operating Frequency (Hz) Not required for halogen luminaires. Provide the average operating frequency based on test data. O N Integer Min Value: 120
Maximum Recommended Ballast/Driver Case Temperature (°C) Halogen luminaires exempt. Provide manufacturer recommended maximum case temperature at the hot spot location. O N Integer
Maximum Ballast/Driver Case Temperature (°C) Halogen luminaires exempt. Provide temperature during normal operation in degrees Celsius (°C). O N Integer
Minimum Operating Temperature (°C) Provide the manufacturer recommended minimum operating temperature. R N Integer Max Value: -18
Additional Allowable Housings Required if two or more allowable housings. O N Text Max Length: 1000
Additional Allowable Finishes Required if two or more allowable finishes. O N Text Max Length: 1000
Additional Allowable Mounting Type Required if two or more allowable mountings. O N Text Max Length: 1000
Additional Allowable Reflectors/Trims Required if two or more allowable reflectors or trims. O N Text Max Length: 1000
Additional Allowable Shades/Diffusers Required if two or more allowable shades or diffusers. O N Text Max Length: 1000
Additional Allowable Light Source Manufacturer Required if two or more allowable light source manufacturers. O N Text Max Length: 1000
Additional Allowable Light Source Model Number Required if two or more allowable light source model numbers. O N Text Max Length: 1000
Additional Allowable Ballast/Driver Manufacturer Required if two or more allowable ballast or driver manufacturers. O N Text Max Length: 1000
Subcomponent Data Source Indicate how subcomponent performance data was obtained. R N Enumeration Data
  • CSD
  • Lab Data
  • Combination
  • N/A (halogen exempt)
Displayed Luminaire Notes Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model’s listing, etc.). O N Text Max Length: 1000

Information for certification bodies to provide to EPA on Outdoor Non-Directional Luminaires certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 1.1 or Version 1.2. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.