| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Product Specific Information  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
- Outdoor Directional Luminaire
|
| Indoor/Outdoor |
Indicate whether the luminaire is intended for outdoor use. |
R |
N |
Enumeration Data |
|
|
| Qualification Status |
Indicate whether the light source has achieved conditional qualification (testing at 40% of rated life) or full qualification. |
R |
N |
Enumeration Data |
|
- Conditional Qualification
- Full Qualification
|
| Date Fully Qualified |
Required for models with a fully qualified listing status. Provide the date the light source achieved full qualification. |
O |
N |
Date |
|
|
| Tested Voltage (V) |
Provide the voltage(s) at which the model was tested. |
R |
Y |
Enumeration Data |
|
|
| Reported Voltage (V) |
Provide the rated/reported voltage(s). |
R |
Y |
Enumeration Data |
|
|
| Lighting Technology |
|
R |
N |
Enumeration Data |
|
- LED
- Fluorescent
- Halogen
- HID
|
| Commercial/Residential |
Indicate whether the luminaire is intended for commercial and/or residential use. |
R |
Y |
Enumeration Data |
|
|
| Source Type |
Indicate one of the allowable source types. |
R |
N |
Enumeration Data |
|
- Self-ballasted CFL (GU24)
- Compact Fluorescent
- Linear Fluorescent
- Circline
- Halogen
- High Pressure Sodium
- Metal Halide
- Ceramic Metal Halide
- GU24 Based Integrated LED Lamp
- LED Light Engine
- Inseparable LED Source (modules, arrays, packages)
|
| Residential Directional Luminaire Type |
Required for residential luminaires. Indicate one of the allowable luminaire types. Only Outdoor Porch Wall Mounts that are qualified under SSL V1.3 prior to the publication of LM-82 or as a family variation of an Outdoor Post-Mount Light should use this template. All others use the Outdoor non-directional template. |
O |
N |
Enumeration Data |
|
- Accent Light Line-voltage
- Accent Light Ceiling Fan Light Kit
- Downlight Recessed
- Downlight Pendant
- Downlight Surface Mount
- Downlight Solid State Retrofit
- Outdoor Post-Mount
- Outdoor Porch Wall Mount
- Outdoor Pendant
- Outdoor Ceiling
- Outdoor Close-to-Ceiling
- Under Cabinet
- Cover Mount
- Inseparable SSL - Other
|
| Inseparable SSL Luminaire Type |
Required for all residential "Inseparable SSL - Other" luminaire types. Indicate the luminaire type. |
O |
N |
Enumeration Data |
|
- Outdoor Ceiling Mount
- Outdoor Close to Ceiling Mount
- Outdoor Porch Wall Mount
- Outdoor Pendant
- Security
- Other
|
| Inseparable SSL Luminaire Description |
Required for "Inseparable SSL -Other" luminaire types. |
O |
N |
Text |
Max Length: 1000
|
|
| Commercial Directional Luminaire Type |
Required for commercial luminaires. Indicate one of the allowable luminaire types. |
O |
N |
Enumeration Data |
|
- Accent Light Line-voltage
- Downlight Recessed
- Downlight Pendant
- Downlight Surface Mount
- Downlight Solid State Retrofit
- Under Cabinet Shelf Mounted Task Light
- Portable Desk Task Light
|
| Light Source Manufacturer |
If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Light Source Model Number |
If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". |
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Light Source is Self-ballasted or has Integrated Driver |
If the light source is removable and is integrated with a power supply such as a driver or ballast, indicate Yes. If the light source is removable but requires a separate power supply, indicate No. If an Inseparable SSL Luminaire indicate N/A. |
R |
N |
Enumeration Data |
|
|
| Light Source Shipped with Fixture? |
No is only allowable when the luminaire is exempt from shipping a lamp with the fixture. |
R |
N |
Enumeration Data |
|
|
| ANSI-IEC Standardized Lamp Shape |
Provide the lamp shape for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines or if the luminaire is an Inseparable SSL Luminaire. |
R |
N |
Enumeration Data |
|
- A15
- A17
- A19
- A21
- A23
- C7
- C9
- CA9
- CA10
- B10
- BA10
- B13
- F10
- F15
- F20
- S11
- S14
- PS25
- PS30
- PS35
- G16.5
- G25
- G30
- G40
- ER30
- ER40
- R14
- R16
- R20
- R30
- R40
- BR30
- BR38
- BR40
- PAR 14
- PAR 16
- PAR 20
- PAR 30
- PAR30L
- PAR38
- MR8
- MR11
- MR16
- T5
- T6
- T7
- T8
- T10
- T12
- Twin T4
- Twin T5
- Quad T4
- Quad T5
- Square T4
- Square T6
- Circular T5
- Circular T9
- Circular T10
- Multi T4
- Multi T5
- U-Bend T8
- U-Bend T12
- ED17
- ED18
- ED28
- BT28
- Other
- N/A
|
| ANSI-IEC Designated Lamp Base Type |
Required for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines or if the luminaire is an Inseparable SSL Luminaire. |
R |
N |
Enumeration Data |
|
- E11
- E12
- E17
- E26
- E39
- EX39
- BA15S
- BA15D
- G4
- GU4
- G5
- GU5.3
- GY5.3
- GY6.35
- 2G7
- 2GX7
- 2G8
- G9
- G10q
- GU10
- 2G11
- G13
- 2G13
- 2GX13
- G23
- G23-2
- GU24
- GX23
- GX23-2
- G24D
- G24q
- GX24q
- GX24Xd
- G32D
- G32Q
- GX32d
- GX32q
- GY32D
- GX53
- R17D
- R7S
- RX7s
- G12
- GX10
- G8.5
- GU6.5
- Other
- N/A
|
| Number of Light Sources per Ballast/Driver |
Required if luminaire is not an Inseparable SSL Luminaire. |
O |
N |
Integer |
|
|
| Number of Light Sources per Luminaire |
Required if luminaire is not an Inseparable SSL Luminaire. |
O |
N |
Integer |
|
|
| Number of Ballasts/Drivers per Luminaire |
Required if luminaire is not an Inseparable SSL Luminaire. |
O |
N |
Integer |
|
|
| External Ballast/Driver Manufacturer |
Required for luminaires utilizing an external power supply. Provide the name of ballast, transformer, or driver manufacturer. Not required for luminaires utilizing LED light engines, GU24 based integrated lamps, halogen, or if the luminaire is an Inseparable SSL Luminaire. |
O |
N |
Text |
Max Length: 1000
|
|
| External Ballast/Driver Model Number |
Required for luminaires utilizing an external power supply. Provide the ballast, transformer, or driver model number. Not required for luminaires utilizing LED light engines, halogen, or GU24 based integrated lamps. |
O |
N |
Text |
Max Length: 1000
|
|
| Claimed Incandescent Equivalency (W) |
Required for models that include equivalency claims on the packaging. |
O |
N |
Integer |
Min Value: 0
|
|
| Measured Input Power (W) |
Provide the measured input power of the model based on test data. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.00
Max Value: 250.00
|
|
| Reported Input Power (W) |
Provide the rated/reported lamp input power of the model, which will appear on the list of ENERGY STAR qualified products. |
R |
N |
Decimal |
No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
|
|
| Luminous Efficacy (lm/W) |
Halogen luminaires exempt. Provide the calculated value based on test data. |
O |
N |
Decimal |
No. of Decimal: 1
Min Value: 24.0
|
|
| Reported Light Output (lm) |
Halogen luminaires exempt. This should be consistent with the value stated on the product packaging and will appear on the list of ENERGY STAR qualified products. |
O |
N |
Integer |
|
|
| Measured Light Output (lm) |
Halogen luminaires exempt. Provide the measured light output of the model based on test data. |
O |
N |
Integer |
|
|
| Lumen Output of Individual Light Source (lm) |
Required for all luminaires with one or more removable light sources. Not required if the luminaire is an Inseparable SSL Luminaire. If there are multiple lumen output values, separate each by a backslash. |
O |
N |
Text |
Max Length: 1000
|
|
| Wattage of Individual Light Source (W) |
Required for all luminaires with one or more removable light sources. Not required if the luminaire is an Inseparable SSL Luminaire. List the light source wattage(s) used in the luminaire. If there are multiple wattages used, separate each by a backslash. |
O |
N |
Text |
Min Length: 0
Max Length: 1000
|
|
| Accent Light: Percentage of Light Falling Within 0°-40° |
Required for luminaires classified as an Accent Light. Indicate value in decimal format (i.e., use .85 for 85%). |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.80
Max Value: 1.00
|
|
| Cove: Percentage of Light Falling Within 30°-60° |
Required for luminaires classified as a Cove Light. Indicate value in decimal format (i.e., use .40 for 40%). |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.35
Max Value: 1.00
|
|
| Downlight, Undercabinet or Portable Desk Task Light: 0°-60° |
Required for luminaires classified as a Downlight, Undercabinet Light, or Portable Desk Task Light. Indicate the percentage of light falling within 0°-60° zone, in decimal format (i.e., use .60 for 60%). |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.60
Max Value: 1.00
|
|
| Outdoor Post Mount: Percentage of Light Falling Within 0°-85° |
Required for luminaires classified as Outdoor Post Mount. Indicate value in decimal format (i.e., use .98 for 98%). |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.95
Max Value: 1.00
|
|
| Light Source Life (hours) |
|
R |
N |
Integer |
Min Value: 2500
|
|
| Average Lumen Maintenance at 40% of Lamp Life |
Required for fluorescent and HID lamps. Indicate value as percentage in decimal format. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.80
Max Value: 1.00
|
|
| Solid State Option 1: LM-80 and TM-21 Projected Time to L70 |
Required for luminaires using Solid State Option 1 to satisfy lumen maintenance requirements. Provide "Reported Lumen Maintenance Life" in hours as determined by EPA provided TM-21 calculator. |
O |
N |
Integer |
Min Value: 35000
|
|
| Solid State Option 2: Average Lumen Maintenance at 6,000 Hours |
Required for luminaires using Solid State Option 2 to satisfy lumen maintenance requirements. Provide value in decimal format (i.e., use .85 for 85%). |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0.918
Max Value: 1.00
|
|
| Nominal Correlated Color Temperature (CCT) |
Provide the nominal CCT which will appear on the list of ENERGY STAR qualified products. |
R |
N |
Enumeration Data |
|
- 2700K
- 3000K
- 3500K
- 4000/4100K
- 5000K
- Other
|
| Amalgam/Non-Amalgam |
Required for models containing mercury. Indicate N/A for other light sources. |
R |
N |
Enumeration Data |
|
|
| Mercury Content (mg) |
Required for models containing mercury. Indicate the amount of mercury (in mg) the model contains. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| Dimmable |
Indicate which dimming mechanism is used or select non-dimmable if luminaire is not capable of dimming. |
R |
N |
Enumeration Data |
|
- Non-Dimmable
- Continuous Dimming
- Step Dimming
|
| Meets Photo Sensor Requirement |
Required for halogen luminaires only. |
O |
N |
Enumeration Data |
|
|
| Meets Motion Sensor Requirement |
Required for halogen luminaires only. |
O |
N |
Enumeration Data |
|
|
| Power Factor |
Halogen luminaires exempt. Provide the average power factor based on test data. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00
|
|
| Current Crest Factor |
Required for discharge lamps (non-self ballasted Fluorescent and HID) only. Provide lamp current crest factor based on test data. |
O |
N |
Decimal |
No. of Decimal: 1
Max Value: 1.8
|
|
| Off-state Power |
Indicate whether the model consumes power in the off-state. |
R |
N |
Enumeration Data |
|
|
| Off-state Power Consumption (Watts) |
Required if off-state power consumption is greater than zero. Provide measured power value. |
O |
N |
Integer |
|
|
| Operating Frequency (Hz) |
Halogen luminaires exempt. Provide the average operating frequency based on test data. |
O |
N |
Integer |
Min Value: 120
|
|
| Maximum Recommended Ballast/Driver Case Temperature (°C) |
Halogen luminaires exempt. Provide manufacturer recommended maximum case temperature at the hot spot location. |
O |
N |
Integer |
|
|
| Maximum Ballast/Driver Case Temperature (°C) |
Halogen luminaires exempt. Provide temperature during normal operation. |
O |
N |
Decimal |
No. of Decimal: 1
|
|
| Minimum Operating Temperature (°C) |
Provide the manufacturer recommended minimum operating temperature. |
R |
N |
Integer |
Max Value: -18
|
|
| Additional Allowable Housings |
Required if two or more allowable housings. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Finishes |
Required if two or more allowable finishes. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Mounting Type |
Required if two or more allowable mountings. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Electrical Connection |
Required if two or more allowable electrical connections for SSL Downlight Retrofits only. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Reflectors/Trims |
Required if two or more allowable reflectors or trims. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Shades/Diffusers |
Required if two or more allowable shades or diffusers. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Light Source Manufacturer |
Required if two or more allowable light source manufacturers. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Light Source Model Number |
Required if two or more allowable light source model numbers. |
O |
N |
Text |
Max Length: 1000
|
|
| Additional Allowable Ballast/Driver/External Power Supply Manu. |
Required if two or more allowable ballast/driver/external power supply manufacturers. |
O |
N |
Text |
Max Length: 1000
|
|
| Subcomponent Data Source |
Required for all luminaires with a removable light source, not required for inseparable SSL luminaires. Indicate how subcomponent performance data was obtained. |
R |
N |
Enumeration Data |
|
- CSD
- Lab Data
- Combination
- N/A (halogen exempt)
|
| Recessed Downlight Ratings |
Required for downlight recessed luminaires. |
O |
N |
Enumeration Data |
|
- Type IC Airtight
- Type Non-IC
- Type Non-IC Airtight
|
| Displayed Luminaire Notes |
Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model’s listing, etc.). |
O |
N |
Text |
Max Length: 1000
|
|