Home > Partner Resources > Third-Party Certification > Certification Body Resources > XML Web Services Submission Process > ENERGY STAR Indoor and Indoor/Outdoor Non-Directional Luminaires Template

ENERGY STAR Indoor and Indoor/Outdoor Non-Directional Luminaires Template

Service Method: Submit_Indoor_and_Indoor_Outdoor_Non_Directional_Luminaires_1_x
Version Number: V1 Indoor and Indoor/Outdoor Non-directional
Description: Information for certification bodies to provide to EPA on Indoor and Indoor/Outdoor Non-Directional Luminaires certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 1.1 or Version 1.2. Test data should be provided at 120 volts. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.
History Subscribe to updates via RSS 2.0:
  • 11/14/12 - Submit_Indoor_and_Indoor_Outdoor_Non_Directional_Luminaires_1_x Final
  • 11/09/12 - Submit_Indoor_and_Indoor_Outdoor_Non_Directional_Luminaires_1_x Updated
  • 10/02/12 - Submit_Indoor_and_Indoor_Outdoor_Non_Directional_Luminaires_1_x Available for Testing
Name Description Required/ Optional Multiple Select Data Type Restrictions Enumerations
ENERGY STAR Manufacturing Partner The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. R N Text Min Length: 1
Max Length: 80
ENERGY STAR Manufacturing Partner's EPA-issued Organization ID This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. R N Integer
Partner Contact Name for This Model Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. R N Text Min Length: 1
Max Length: 200
Type of Transaction Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. R N Enumeration Data
  • Initial Certification
  • Modification
  • Certification Withdrawn
  • Recertification
  • Registration
Reason for Transaction Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. R N Enumeration Data
  • Initial Certification: Model Meets ENERGY STAR Requirements
  • Registration: Included in Verification Testing Pool
  • Modification: Added Model Name/Number
  • Modification: Removed Model Name/Number
  • Modification: Changed Model Name/Number
  • Modification: Changed Data
  • Modification: Rerated Models
  • Modification: Other (If Other, List in Notes Field)
  • Certification Withdrawn: No Longer Available
  • Certification Withdrawn: Manufacturer Voluntary Withdrawal
  • Certification Withdrawn: Delisted - Issue with Partnership
  • Certification Withdrawn: Disqualified Model - Failed Testing
  • Certification Withdrawn: Other (If Other, List in Notes Field)
  • Recertification: Model Meets ENERGY STAR Requirements
  • Recertification: Other (If Other, List in Notes Field)
Date of Transaction Type This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. R N Date
ENERGY STAR Model Identifier ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes. Naming convention is as follows: ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID [[MODELNUMBER]] = Provide Model Number of the model [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Certification ID Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification. Naming convention for Certification_ID is as follows: CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. R N Text Min Length: 1
Max Length: 400
Family ID Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families. *NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID. Naming conventions for Family_ID are as follows: FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]] Note : Total Max length of this must not exceed 400 characters. [[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID, [[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it. [[7 Digit-randomnumber]] = Provide a random number of seven digits. O N Text Max Length: 400
Model Name Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Model Number Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. R N Text Min Length: 1
Max Length: 255
Brand Name Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. R N Text Min Length: 1
Max Length: 200
Tested Model Name Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Tested Model Number Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. R N Text Min Length: 1
Max Length: 255
Additional Models Represented by Family, Series, or DOE Basic Model
Additional Models Represented by Family, Series, or DOE Basic Model Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. O Y
  • Additional Model Name
Provide each Additional Model Name as a separate data entry. O N Text Max Length: 255
  • Additional Model Number
Provide each Additional Model Number as a separate data entry. O N Text Max Length: 255
  • Additional Identifying Information
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. O N Text Max Length: 255
Is the Partner Listed the Original Equipment Manufacturer (OEM)? Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. R N Enumeration Data
  • Yes
  • No
If the Partner is not the Original Equipment Manufacturer, Who Is? In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. O N Text Max Length: 80
Currently Available on Market? If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. R N Enumeration Data
  • Yes
  • No
Date Available on Market Date model is first sold within one or more markets. R N Date
Date Tested Date of laboratory test. If multiple test reports, provide the most recent date. R N Date
Date Certification Body Notified Partner of Model Certification. The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. R N Date
Certification Body Contact Name for this Model The name of the primary certification body contact responsible for any questions concerning the certification of the model. R N Text Min Length: 1
Max Length: 200
Laboratory
Laboratory Include information about one or more laboratories in which the model was tested. O Y
  • Laboratory's EPA-issued Organization ID
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. O N Integer
  • Laboratory Contact for this Model
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. O N Text Max Length: 200
In What Markets Is this Model Sold? Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. R Y Enumeration Data
  • Australia
  • New Zealand
  • Canada
  • Europe
  • Japan
  • Switzerland
  • Taiwan
  • United States
Notes Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. O N Text Max Length: 2000
Indoor_and_Indoor_Outdoor_Non_Directional_Luminaires info
ENERGY STAR Specification Version R N Enumeration Data
  • 1.1
  • 1.2
Product Type R N Enumeration Data
  • Indoor Non-Directional Luminaire
  • Indoor/Outdoor Non-Directional Luminaire
Indoor/Outdoor Indicate whether the luminaire is intended for indoor or indoor and outdoor use. R N Enumeration Data
  • Indoor Non-Directional Luminaire
  • Indoor/Outdoor Non-Directional Luminaire
Qualification Status Indicate whether the light source has achieved conditional qualification (testing at 40% of rated life) or full qualification. R N Enumeration Data
  • Conditional Qualification
  • Full Qualification
Date Fully Qualified Required for models with a fully qualified listing status. Provide the date the light source achieved full qualification. O N Date
Tested Voltage (V) Provide the voltage(s) at which the model was tested. R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Reported Voltage (V) Provide the rated/reported voltage(s). R Y Enumeration Data
  • 120
  • 208
  • 240
  • 277
Lighting Technology R N Enumeration Data
  • LED
  • Fluorescent
  • HID
Residential Non-Directional Luminaire Type Indicate one of the luminaire types. R N Enumeration Data
  • Bath Vanity
  • Ceiling Mount
  • Close to Ceiling Mount
  • Ceiling Fan Light Kit
  • Chandelier
  • Decorative Pendant
  • Linear Strip
  • Wall Sconces
  • Wrapped Lens
  • Residential Portable Desk Task Light
  • Portable Floor Task Light
  • Table Lamps
  • Ventilating Fan Light
  • Floor Lamp
  • Torchiere
  • Porch (wall mounted)
  • Security
  • Other
Luminaire Description Required if luminaire type is Other. O N Text Max Length: 1000
Source Type Indicate one of the allowable source types. R N Enumeration Data
  • Self-ballasted CFL (GU24)
  • Compact Fluorescent
  • Linear Fluorescent
  • Circline
  • High Pressure Sodium
  • Metal Halide
  • Ceramic Metal Halide
  • GU24 Based Integrated LED Lamp
  • LED Light Engine
Light Source Model Number If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". R N Text Min Length: 1
Max Length: 1000
Light Source Manufacturer If luminaire is exempt from shipping with lamp, please indicate "Not shipped with lamp". R N Text Min Length: 1
Max Length: 1000
Light Source is Self-ballasted or has Integrated Driver If the light source is removable and is integrated with a power supply such as a driver or ballast, indicate Yes. If the light source is removable but requires a separate power supply, indicate No. R N Enumeration Data
  • Yes
  • No
Light Source Shipped with Fixture? No is only allowable when the luminaire is exempt from shipping a lamp with the fixture. R N Enumeration Data
  • Yes
  • No
ANSI-IEC Standardized Lamp Shape Provide the lamp shape for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines. R N Enumeration Data
  • A15
  • A17
  • A19
  • A21
  • A23
  • C7
  • C9
  • CA9
  • CA10
  • B10
  • BA10
  • B13
  • F10
  • F15
  • F20
  • S11
  • S14
  • PS25
  • PS30
  • PS35
  • G16.5
  • G25
  • G30
  • G40
  • ER30
  • ER40
  • R14
  • R16
  • R20
  • R30
  • R40
  • BR30
  • BR38
  • BR40
  • PAR14
  • PAR16
  • PAR20
  • PAR30
  • PAR30L
  • PAR38
  • MR8
  • MR11
  • MR16
  • T5
  • T6
  • T7
  • T8
  • T10
  • T12
  • Twin T4
  • Twin T5
  • Quad T4
  • Quad T5
  • Square T4
  • Square T6
  • Circular T5
  • Circular T9
  • Circular T10
  • Multi T4
  • Multi T5
  • U-Bend T8
  • U-Bend T12
  • ED17
  • ED18
  • ED28
  • BT28
  • Other
  • N/A
ANSI-IEC Designated Lamp Base Type Required for luminaires with a removable light source. Indicate N/A for luminaires utilizing LED light engines. R N Enumeration Data
  • E11
  • E12
  • E17
  • E26
  • E39
  • EX39
  • BA15S
  • BA15D
  • G4
  • GU4
  • G5
  • GU5.3
  • GY5.3
  • GY6.35
  • 2G7
  • 2GX7
  • 2G8
  • G9
  • G10q
  • GU10
  • 2G11
  • G13
  • 2G13
  • 2GX13
  • G23
  • G23-2
  • GU24
  • GX23
  • GX23-2
  • G24D
  • G24q
  • GX24q
  • GX24Xd
  • G32D
  • G32Q
  • GX32d
  • GX32q
  • GY32D
  • GX53
  • R17D
  • R7S
  • RX7s
  • G12
  • GX10
  • G8.5
  • GU6.5
  • Other
  • N/A
External Ballast/Driver Manufacturer Required for luminaires utilizing an external power supply. Provide the name of ballast, transformer, or driver manufacturer. Not required for luminaires utilizing LED light engines or GU24 based integrated lamps. O N Text Max Length: 1000
External Ballast/Driver Model Number Required for luminaires utilizing an external ballast or driver. Provide the ballast, transformer, or driver model number. Not required for luminaires utilizing LED light engines or GU24 based integrated lamps. O N Text Max Length: 1000
Number of Light Sources per Ballast/Driver R N Integer
Number of Light Sources per Luminaire R N Integer
Number of Ballasts/Drivers per Luminaire R N Integer
Claimed Incandescent Equivalency (W) Required for models that include equivalency claims on the packaging. O N Integer
Measured Input Power (W) Provide the measured input power of the model based on test data. R N Decimal No. of Decimal: 2
Min Value: 0.00
Max Value: 250.00
Reported Input Power (W) Provide the rated/reported lamp input power of the model, which will appear on the list of ENERGY STAR qualified products. R N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 250.0
Source Luminous Efficacy (lm/W) Provide the calculated value based on test data. R N Decimal No. of Decimal: 1
Min Value: 40.0
Measured Source Light Output (lm) Provide the measured light output of the model based on test data. R N Integer Min Value: 250
Reported Source Light Output (lm) Provide the reported source light output which should be consistent with the value stated on the product packaging and will appear on the list of ENERGY STAR qualified products. R N Integer Min Value: 250
Lumen Output of Individual Light Source (lm) If there are multiple lumen output values, separate each by a backslash. R N Text Min Length: 1
Max Length: 1000
Wattage of Individual Light Source (W) List the light source wattage(s) used in the luminaire. If there are multiple wattages used, separate each by a backslash. R N Text Min Length: 1
Max Length: 1000
Light Source Life (hours) R N Integer Min Value: 6000
Average Lumen Maintenance at 40% of Lamp Life Required for fluorescent and HID lamps. Indicate value as percentage in decimal format. O N Decimal No. of Decimal: 2
Min Value: 0.80
Max Value: 1.00
Solid State Option 1: LM-80 and TM-21 Projected Time to L70 Required for luminaires using Solid State Option 1 to satisfy lumen maintenance requirements. Indicate "Reported Lumen Maintenance Life" time in hours as determined by EPA provided TM-21 calculator. O N Integer Min Value: 25000
Solid State Option 2: Average Lumen Maintenance at 6,000 Hours Required for luminaires using Solid State Option 2 to satisfy lumen maintenance requirements. O N Decimal No. of Decimal: 3
Min Value: 0.918
Color Rendering Index (CRI) Provide the CRI value based on test data. R N Integer Min Value: 80
Max Value: 100
Nominal Correlated Color Temperature (CCT) Provide the nominal CCT which will appear on the list of ENERGY STAR qualified products. R N Enumeration Data
  • 2700K
  • 3000K
  • 3500K
  • 4000/4100K
Correlated Color Temperature (CCT) Provide the measured CCT value based on test data. R N Integer
Percent of Samples within 7-step Mac Adam Ellipse or Quadrangle Provide value in decimal format (i.e., use .90 for 90%). R N Decimal No. of Decimal: 2
Min Value: 0.90
Max Value: 1.00
Color Maintenance Requirements: Change in Chromaticity Required only for solid state luminaires. Provide change in chromaticity between 0 and 6,000 hours. O N Decimal No. of Decimal: 3
Max Value: 0.007
Amalgam/Non-Amalgam Required for models containing mercury. Indicate N/A for other light sources. R N Enumeration Data
  • Amalgam
  • Non-Amalgam
  • N/A
Mercury Content (mg) Required for models containing mercury. Indicate the amount of mercury (in mg) the model contains. O N Decimal No. of Decimal: 1
Source Start Time (milliseconds) Provide the measured start time of the model based on test data. R N Integer Min Value: 0
Max Value: 1000
Source Run-up Time (seconds) Provide the measured run-up time of the model based on test data. R N Decimal No. of Decimal: 1
Min Value: 0.0
Max Value: 180.0
Dimmable Indicate which dimming mechanism is used or select non-dimmable if luminaire is not capable of dimming. R N Enumeration Data
  • Non-Dimmable
  • Continuous Dimming
  • Step Dimming
Power Factor Provide the average power factor based on test data. R N Decimal No. of Decimal: 2
Min Value: 0.50
Max Value: 1.00
Current Crest Factor Required for discharge lamps (non-self ballasted Fluorescent and HID) only. Provide lamp current crest factor based on test data. O N Decimal No. of Decimal: 1
Min Value: 0
Max Value: 1.8
Off-state Power Indicate whether the model consumes power in the off-state. R N Enumeration Data
  • Yes
  • No
Off-state Power Consumption (W) Required if off-state power consumption is greater than zero. Provide measured power value. O N Decimal No. of Decimal: 1
Max Value: 1.5
Operating Frequency (Hz) Provide the average operating frequency based on test data. R N Integer Min Value: 120
Maximum Recommended Ballast/Driver Case Temperature (°C) Provide manufacturer recommended maximum case temperature at the hot spot location. R N Integer
Maximum Ballast/Driver Case Temperature (°C) Provide temperature during normal operation. R N Decimal No. of Decimal: 1
Minimum Operating Temperature (°C) Required for Indoor/Outdoor luminaires. Provide the manufacturer recommended minimum operating temperature. O N Integer Max Value: -18
Additional Allowable Housings Required if two or more allowable housings. O N Text Max Length: 1000
Additional Allowable Finishes Required if two or more allowable finishes. O N Text Max Length: 1000
Additional Allowable Mounting Type Required if two or more allowable mountings. O N Text Max Length: 1000
Additional Allowable Reflectors/Trims Required if two or more allowable reflectors or trims. O N Text Max Length: 1000
Additional Allowable Shades/Diffusers Required if two or more allowable shades or diffusers. O N Text Max Length: 1000
Additional Allowable Light Source Manufacturer Required if two or more allowable light source manufacturers. O N Text Max Length: 1000
Additional Allowable Light Source Model Number Required if two or more allowable light source model numbers. O N Text Max Length: 1000
Additional Allowable Light Source Correlated Color Temperature Required if two or more allowable light source correlated color temperatures. O N Integer
Additional Allowable Ballast/Driver/External Power Supply Manu. Required if two or more allowable ballast/driver/external power supply manufacturers. O N Text Max Length: 1000
Subcomponent Data Source Indicate how subcomponent performance data was obtained. R N Enumeration Data
  • CSD
  • Test Report
  • Combination
Displayed Luminaire Notes Provide information on certification relevant to the consumer (i.e. product variations, unique issues concerning the model’s listing, etc.). O N Text Max Length: 1000

Information for certification bodies to provide to EPA on Indoor and Indoor/Outdoor Non-Directional Luminaires certified as meeting the eligibility criteria for the ENERGY STAR® Program Requirements for Luminaires Version 1.1 or Version 1.2. Test data should be provided at 120 volts. Additional instructions for submitting this information to EPA are available at www.energystar.gov/cbresources.