| Name |
Description |
Required/ Optional |
Multiple Select |
Data Type |
Restrictions |
Enumerations |
| ENERGY STAR Manufacturing Partner |
The ENERGY STAR Manufacturing Partner is the organization that has signed an ENERGY STAR Partnership Agreement and labels the model. This organization is typically the brand owner. |
R |
N |
Text |
Min Length: 1
Max Length: 80
|
|
| ENERGY STAR Manufacturing Partner's EPA-issued Organization ID |
This EPA-issued ID is the number assigned to the ENERGY STAR Manufacturing Partner. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the organization's name. |
R |
N |
Integer |
|
|
| Partner Contact Name for This Model |
Provide the ENERGY STAR Manufacturing Partner contact responsible for this certified model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Type of Transaction |
Include the Type of Transaction associated with the certified model. Only the options included in the enumeration list may be provided. Initial certification must only be used if the model has never been submitted and does not have an ENERGY STAR Model Identifier. Registration must only be used for select types of models where EPA allows certification bodies to add previously qualified models to their programs for purposes of verification testing only. Modification must be used for administrative changes, including rerating the model(s). Certification withdrawn must be used when the model is no longer certified as ENERGY STAR. Recertification will rarely be used and must be approved by EPA prior to the transaction. |
R |
N |
Enumeration Data |
|
- Initial Certification
- Modification
- Certification Withdrawn
- Recertification
- Registration
|
| Reason for Transaction |
Include the Reason for Transaction associated with the Type of Transaction. Only the reasons included in the enumeration list may be provided. If "other" is provided, list further details in the notes field. The certification body will determine when it is appropriate to use the reasons associated with "Initial Certification," "Registration" or "Modification." The reasons "Manufacturer Voluntary Withdrawal" and "No Longer Available" may be determined by the certification body and must only be associated with the transaction type "Certification Withdrawn." For all other cases of "Certification Withdrawn" or "Recertification," EPA must determine the appropriate reason and provide direction to the certification body. |
R |
N |
Enumeration Data |
|
- Initial Certification: Model Meets ENERGY STAR Requirements
- Registration: Included in Verification Testing Pool
- Modification: Added Model Name/Number
- Modification: Removed Model Name/Number
- Modification: Changed Model Name/Number
- Modification: Changed Data
- Modification: Rerated Models
- Modification: Other (If Other, List in Notes Field)
- Certification Withdrawn: No Longer Available
- Certification Withdrawn: Manufacturer Voluntary Withdrawal
- Certification Withdrawn: Delisted - Issue with Partnership
- Certification Withdrawn: Disqualified Model - Failed Testing
- Certification Withdrawn: Other (If Other, List in Notes Field)
- Recertification: Model Meets ENERGY STAR Requirements
- Recertification: Other (If Other, List in Notes Field)
|
| Date of Transaction Type |
This date must be the same as the date when the Type of Transaction occurred. For example, the initial certification date must be the date the certification body notified the partner of model certification. |
R |
N |
Date |
|
|
| ENERGY STAR Model Identifier |
ENERGY_STAR_Model_Identifier is a unique string of characters generated by certification bodies in accordance with EPA's ENERGY_STAR_Model_Identifier standard. ENERGY_STAR_Model_Identifier serves to distinguish models with non-identical performance characteristics. A unique ENERGY_STAR_Model_Identifier must be assigned to each set of performance data that represents a model. Models in a family, series, or DOE basic model group that differ by one or more performance characteristics must be assigned different and unique ENERGY_STAR_Model_Identifiers. ENERGY_STAR_Model_Identifier is different from Certification_ID or Family_ID, which may apply to several models that differ in terms of reported attributes.
Naming convention is as follows:
ES_[[ManufacturerOID]]_[[MODELNUMBER]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issued O_ID
[[MODELNUMBER]] = Provide Model Number of the model
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Certification ID |
Certification_ID is a unique string of characters generated by certification bodies in accordance with EPA's Certifcation_ID standard. Certification_ID serves to distinguish one or more models with differing performance characteristics under a single certification in order to track models associated with that certification.
Naming convention for Certification_ID is as follows:
CER_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
R |
N |
Text |
Min Length: 1
Max Length: 400
|
|
| Family ID |
Family_ID is a unique string of characters generated by certification bodies in accordance with EPA's Family_ID standard. Family_ID serves to identify models under the same certification that are part of the same model family, series, or DOE basic model group. Family_ID may only be included for models where the ENERGY STAR specification supports families.
*NOTE* Under a single certification, certification bodies may or may not have a Family_ID listed. A Family_ID must not be listed if the certification is comprised of only a single model. If there is a Family_ID listed, all models within the certification listed must also have the same Family_ID.
Naming conventions for Family_ID are as follows:
FAM_[[ManufacturerOID]]_[[MMDDYYYYH24MISS]]_[[7 Digit-randomnumber]]
Note : Total Max length of this must not exceed 400 characters.
[[ManufacturerOID]] = Provide Manufacturer EPA issues O_ID,
[[MMDDYYYYH24MISS]] = Create date time string in the format where MM= month number, DD - Day number, YYYY = Year number, H24 hours (0-23), MI minute number, SS seconds. This typically indicates the date of certification, but there are no validations performed on it.
[[7 Digit-randomnumber]] = Provide a random number of seven digits. |
O |
N |
Text |
Max Length: 400
|
|
| Model Name |
Provide the Model Name of the certified model. If the certified model is part of a model family, include the family model name. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Model Number |
Provide the Model Number of the certified model. If the certified model is part of a model family, include the family model number. The use of wildcards is allowed, but may limit the ability to search for a specific model name. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Brand Name |
Provide the model Brand Name in this field. To aid with consumer model searches, use consistent spelling, punctuation, and capitalization when providing brand names. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Tested Model Name |
Provide the model name of the specific model that was tested. This will be the same as the Model Name unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Tested Model Number |
Provide the model number of the specific model that was tested. This will be the same as the Model Number unless this is a model family or private labeling submission. |
R |
N |
Text |
Min Length: 1
Max Length: 255
|
|
| Additional Models Represented by Family, Series, or DOE Basic Model |
| Additional Models Represented by Family, Series, or DOE Basic Model |
Additional Models Represented by Family, Series, or DOE Basic Model allows the listing of multiple additional models that are part of the same certification where performance characteristics are the same. The additional models may be identified by multiple sets of a model name and/or model number and/or additional identifying information. Each uniquely identified additional model name/number/identifier set must be listed as a separate entry within this field and must not be a comma-separated list. The use of wildcards is allowed, but may limit the ability to search for specific additional model names/numbers/identifiers. |
O |
Y |
|
|
|
|
Provide each Additional Model Name as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
Provide each Additional Model Number as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
- Additional Identifying Information
|
Provide any Additional Identifying Information associated with the Model Name and/or Model Number. The identifying information may be used by consumers, incentive programs, or retailers to identify this model or model family. This includes, but is not limited to, SKUs, UPC codes, retail numbers, and/or descriptions of models included/not included in the reported Model Family. Provide each Additional Identifying Information as a separate data entry. |
O |
N |
Text |
Max Length: 255
|
|
|
| Is the Partner Listed the Original Equipment Manufacturer (OEM)? |
Indicate whether or not the ENERGY STAR Manufacturing Partner that labels this model also manufactures this model. |
R |
N |
Enumeration Data |
|
|
| If the Partner is not the Original Equipment Manufacturer, Who Is? |
In the case that the manufacturer partner listed is not the original equipment manufacturer (OEM), provide the name of the OEM. The OEM is the organization that has manufactured the model. |
O |
N |
Text |
Max Length: 80
|
|
| Currently Available on Market? |
If model is currently available, indicate "Yes." Otherwise, indicate "No." Note that all available models are displayed on an ENERGY STAR qualified product list and are subject to verification testing. |
R |
N |
Enumeration Data |
|
|
| Date Available on Market |
Date model is first sold within one or more markets. |
R |
N |
Date |
|
|
| Date Tested |
Date of laboratory test. If multiple test reports, provide the most recent date. |
R |
N |
Date |
|
|
| Date Certification Body Notified Partner of Model Certification. |
The date the certification body notifies the manufacturer that the model is certified as ENERGY STAR. |
R |
N |
Date |
|
|
| Certification Body Contact Name for this Model |
The name of the primary certification body contact responsible for any questions concerning the certification of the model. |
R |
N |
Text |
Min Length: 1
Max Length: 200
|
|
| Laboratory |
| Laboratory |
Include information about one or more laboratories in which the model was tested. |
O |
Y |
|
|
|
- Laboratory's EPA-issued Organization ID
|
This EPA-issued ID is the number assigned to the EPA-recognized laboratory that tested the model. This ID can be located via the certification body's My ENERGY STAR Account (MESA) and searching for the laboratory's name. This field is required for all certified models. |
O |
N |
Integer |
|
|
- Laboratory Contact for this Model
|
The name of the primary laboratory contact responsible for any questions concerning the testing of the model. This information is required for each laboratory indicated. |
O |
N |
Text |
Max Length: 200
|
|
|
| In What Markets Is this Model Sold? |
Models must be sold in one or more of the ENERGY STAR partner markets provided in the enumeration list. |
R |
Y |
Enumeration Data |
|
- Australia
- New Zealand
- Canada
- Europe
- Japan
- Switzerland
- Taiwan
- United States
|
| Notes |
Provide any additional, relevant information related to the certification, including the reason for the transaction if "Other" is provided. |
O |
N |
Text |
Max Length: 2000
|
|
Product Specific Information  |
| ENERGY STAR Specification Version |
|
R |
N |
Enumeration Data |
|
|
| Product Type |
|
R |
N |
Enumeration Data |
|
- 1 or 2 Socket Server
- 3 or 4 Socket Server
|
| Model Number or Config ID for Minimum or Single Configuration |
Required if server family has a minimum configuration, as defined in Section F.2 of the Enterprise Server Specification Version 1.1; or if a single server configuration is being submitted. |
O |
N |
Text |
Max Length: 1000
|
|
| Model Number or Configuration ID for Maximum Configuration |
Required if server model/family has a maximum configuration, as defined in Section F.1 of the Enterprise Server Specification Version 1.1. |
O |
N |
Text |
Max Length: 1000
|
|
| Product Form Factor |
|
R |
N |
Enumeration Data |
|
- Tower/Pedestal
- Rackmount
- Multinode
- Other
|
| Service Processor Installed |
|
R |
N |
Enumeration Data |
|
|
| Available Processor Sockets |
|
R |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Number Of Installed Processors |
|
R |
N |
Integer |
Min Value: 1
Max Value: 4
|
|
| Cores Per Processor |
|
R |
N |
Integer |
Min Value: 1
|
|
| Processor Brand |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Processor Model Name |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Processor Speed for Minimum or Single Configuration (GHz) |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Decimal |
No. of Decimal: 3
Min Value: 0
|
|
| Processor Speed For Maximum Configuration (GHz) |
Required if server model/family has a maximum configuration. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
|
|
| Memory Manufacturer |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Memory Model Number |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| System Memory for Minimum or Single Configuration (GB) |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Decimal |
Min Value: 0
|
|
| System Memory for Maximum Configuration (GB) |
Required if server model/family has a maximum configuration. |
O |
N |
Decimal |
Min Value: 0
|
|
| Size Per DIMM (GB) |
For product family qualifications with variable sizes per DIMM, provide the size in GB of the maximum memory DIMM. |
R |
N |
Decimal |
Min Value: 0
|
|
| Number of Installed DIMMs for Minimum or Single Configuration |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of Installed DIMMs for Maximum Configuration |
Required if server model/family has a maximum configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Total Installed Memory for Minimum or Single Configuration (GB) |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Decimal |
Min Value: 0
|
|
| Total Installed Memory for Maximum Configuration (GB) |
Required if server model/family has a maximum configuration. |
O |
N |
Decimal |
Min Value: 0
|
|
| Hard Drive Manufacturer |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Hard Drive Brand |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Hard Drive Model Number |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Hard Drive Speed (RPM) |
|
R |
N |
Integer |
|
|
| Number of Hard Drives for Minimum or Single Configuration |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of Hard Drives for Maximum Configuration |
Required if server model/family has a maximum configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Total Installed Stor. Capacity for Minimum or Single Config (GB) |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Decimal |
Min Value: 0
|
|
| Total Installed Storage Capacity for Maximum Configuration (GB) |
Required if server model/family has a maximum configuration. |
O |
N |
Decimal |
Min Value: 0
|
|
| I/O Device 1 Manufacturer |
Required if server family/model contains at least one I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Brand |
Required if server family/model contains at least one I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Model Number |
Required if server family/model contains at least one I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 1 Type |
Required if server family/model contains at least one I/O Device. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 1 Rated Link Speed Per Connection (Gbit) |
Required if server family/model contains at least one I/O Device. |
O |
N |
Decimal |
Min Value: 0
|
|
| I/O Device 1 Number Of Active Ports |
Required if server family/model contains at least one I/O Device. |
O |
N |
Integer |
Min Value: 0
|
|
| Is I/O Device 1 An Onboard Or Add-In Device? |
Required if server family/model contains at least one I/O Device. |
O |
N |
Enumeration Data |
|
|
| I/O Device 2 Manufacturer |
Required if server family/model contains a second I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Brand |
Required if server family/model contains a second I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Model Number |
Required if server family/model contains a second I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 2 Type |
Required if server family/model contains a second I/O Device. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 2 Rated Link Speed Per Connection (Gbit) |
Required if server family/model contains a second I/O Device. |
O |
N |
Decimal |
Min Value: 0
|
|
| I/O Device 2 Number of Active Ports |
Required if server family/model contains a second I/O Device. |
O |
N |
Integer |
Min Value: 0
|
|
| Is I/O Device 2 An Onboard Or Add-In Device? |
Required if server family/model contains a second I/O Device. |
O |
N |
Enumeration Data |
|
|
| I/O Device 3 Manufacturer |
Required if server family/model contains a third I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Brand |
Required if server family/model contains a third I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Model Number |
Required if server family/model contains a third I/O Device. |
O |
N |
Text |
Max Length: 1000
|
|
| I/O Device 3 Type |
Required if server family/model contains a third I/O Device. |
O |
N |
Enumeration Data |
|
- Ethernet
- InfiniBand
- External RAID/SAS Controllers
- Fibre Channel
- Other
|
| I/O Device 3 Rated Link Speed Per Connection (Gbit) |
Required if server family/model contains a third I/O Device. |
O |
N |
Decimal |
Min Value: 0
|
|
| I/O Device 3 Number of Active Ports |
Required if server family/model contains a third I/O Device. |
O |
N |
Integer |
Min Value: 0
|
|
| Is I/O Device 3 an Onboard or Add-in Device? |
Required if server family/model contains a third I/O Device. |
O |
N |
Enumeration Data |
|
|
| Additional I/O Devices |
Required if product contains more than three I/O devices. For each additional I/O device, provide the following: Manufacturer Name, Brand Name, Model Number, Device Type, Rated Link Speed Per Connection (Gbit), Number of Active Ports, and if the device is Onboard or an Add-in Device. |
O |
N |
Text |
Max Length: 1000
|
|
| Power Supply Rated Output (W) |
|
R |
N |
Integer |
|
|
| Number of Power Supplies Installed for Min. or Single Config. |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Integer |
Min Value: 0
|
|
| Number of Power Supplies Installed for Maximum Configuration |
Required if server model/family has a maximum configuration. |
O |
N |
Integer |
Min Value: 0
|
|
| Minimum or Single Config. Number of PSU for Redundancy |
Required if server family has a minimum configuration or if a single server configuration is being submitted; and contains power supplies installed for redundancy. |
O |
N |
Integer |
Min Value: 0
|
|
| Maximum Configuration Number of Power Supplies for Redundancy |
Required if server model/family has a maximum configuration and contains power supplies installed for redundancy. |
O |
N |
Integer |
Min Value: 0
|
|
| Name of Operating System Used for Testing |
|
R |
N |
Text |
Min Length: 1
Max Length: 1000
|
|
| Available Power Saving Features |
|
R |
Y |
Enumeration Data |
|
- Dynamic voltage and frequency scaling of processor(s)
- Processor or core reduced power states
- Power capping
- Variable speed fan control based on power or thermal readings
- Low power memory states
- Low power I/O states
- Other
- None
|
| Enabled Power Saving Features |
Identify Power Saving Features enabled by default upon shipment. |
R |
Y |
Enumeration Data |
|
- Dynamic voltage and frequency scaling of processor(s)
- Processor or core reduced power states
- Power capping
- Variable speed fan control based on power or thermal readings
- Low power memory states
- Low power I/O states
- Other
- N/A
|
| Power Supply Efficiency at 10 Percent Load (%) |
Provide the Power Supply Efficiency percentage as a decimal number between 0 and 1. (i.e. 85% = 0.85) |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Supply Efficiency at 20 Percent Load (%) |
Provide the Power Supply Efficiency percentage as a decimal number between 0 and 1. (i.e. 85% = 0.85) |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Supply Efficiency at 50 Percent Load (%) |
Provide the Power Supply Efficiency percentage as a decimal number between 0 and 1. (i.e. 85% = 0.85) |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Supply Efficiency at 100 Percent Load (%) |
Provide the Power Supply Efficiency percentage as a decimal number between 0 and 1. (i.e. 85% = 0.85) |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Factor at 10 Percent Load |
Provide the Power Factor as a decimal number between 0 and 1. |
O |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Factor at 50 Percent Load |
Provide the Power Factor as a decimal number between 0 and 1. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Factor at 20 Percent Load |
Provide the Power Factor as a decimal number between 0 and 1. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Power Factor at 100 Percent Load |
Provide the Power Factor as a decimal number between 0 and 1. |
R |
N |
Decimal |
No. of Decimal: 2
Min Value: 0
Max Value: 1
|
|
| Idle Power Draw at 230V for Minimum or Single Configuration (W) |
Required if server family has a minimum configuration or if a single server configuration is being submitted; and one of the following is true about the server family or single configuration:
(a) The power supply type is Ac-Dc Single-output; OR
(b) The power supply is an Ac-Dc Multi-output supply capable of operating at 230 V output. |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at 230V for Maximum Configuration (W) |
Required if server model/family has a maximum configuration and one of the following is true about the server family:
(a) The power supply type is Ac-Dc Single-output; OR
(b) The power supply is an Ac-Dc Multi-output supply capable of operating at 230 V output. |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at 115V for Minimum or Single Configuration (W) |
Required if server family has a minimum configuration or if a single server configuration is being submitted; and the power supply type is Ac-Dc Multi-output supply capable of operating at 115 V output. |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at 115V for Maximum Configuration (W) |
Required if server model/family has a maximum configuration; and the power supply type is Ac-Dc Multi-output supply capable of operating at 115 V output. |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at 100V for Minimum or Single Configuration (W) |
May be submitted if server family has a minimum configuration or if a single server configuration is being submitted; and the server is shipped to the Japanese Market.
Idle Power Draw data must also be provided at either 230V, 115V, or both, as noted in Table 1 of the ENERGY STAR Computer Server Test Method (Rev. Aug-2010). |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at 100V for Maximum Configuration |
May be submitted if server model/family has a maximum configuration; and the server is shipped to the Japanese Market.
Idle Power Draw data must also be provided at either 230V, 115V, or both, as noted in Table 1 of the ENERGY STAR Computer Server Test Method (Rev. Aug-2010). |
O |
N |
Decimal |
Min Value: 0
|
|
| Idle Power Draw at +/- 53 V DC for Minimum or Single Config. |
Required if server family has a minimum configuration or if a single server configuration is being submitted; and the power supply type is Dc-Dc. |
O |
N |
Decimal |
|
|
| Idle Power Draw at +/- 53V DC for Maximum Configuration (W) |
Required if server model/family has a maximum configuration; and the power supply type is Dc-Dc. |
O |
N |
Decimal |
|
|
| Full Load Testing Voltage/Frequency for Minimum or Single Config |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Enumeration Data |
|
- 230 Vac, 50 Hz
- 230 Vac, 60 Hz
- 115 Vac, 60 Hz
- 100 Vac, 50 Hz
- 100 Vac, 60 Hz
|
| Full Load Testing Voltage/Frequency for Maximum Configuration |
Required if server model/family has a maximum configuration. |
O |
N |
Enumeration Data |
|
- 230 Vac, 50 Hz
- 230 Vac, 60 Hz
- 115 Vac, 60 Hz
- 100 Vac, 50 Hz
- 100 Vac, 60 Hz
|
| Full Power Load for Minimum or Single Configuration (W) |
Required if server family has a minimum configuration or if a single server configuration is being submitted. |
O |
N |
Decimal |
Min Value: 0
|
|
| Full Power Load for Maximum Configuration (W) |
Required if server model/family has a maximum configuration. |
O |
N |
Decimal |
Min Value: 0
|
|
| Does Server Meet Data and Output Requirements in Section 3.6? |
|
R |
N |
Enumeration Data |
|
|
| Does Model Meet Processor Power Management Requirements? |
Required if product is a 3S or 4S Model. Processor Power Management Requirements are defined in Section 3.3 of the specification. |
O |
N |
Enumeration Data |
|
|
| Processor Power Management Enabled in Hardware on Shipment? |
|
R |
N |
Enumeration Data |
|
|